In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to collect, distribute, and transmit electrical energy. There are two kinds of bus connection methods for bus bar connection and double bus connection, and today Shanxi power distribution cabinet manufacturer Jin Taiheng will tell you about the advantages and disadvantages of single bus connection.
1. Soft start function
The hard start of the motor has a severe impact on the power grid, and will also require too high the capacity of the power grid, and the large current and vibration that occur during the start will cause great damage to the baffle and valve, and the service life of the equipment and pipeline will be extremely unlucky. After the use of inverter energy-saving equipment, the soft start function of the inverter will make the starting current start from zero, and the maximum value will not exceed the rated current, which reduces the impact on the power grid and the requirements for power supply capacity, and prolongs the service life of equipment and valves. The maintenance cost of the equipment is saved.
At the beginning of the birth of the inverter, it is for the most widely used three-phase asynchronous squirrel cage motor to do, the speed formula of the three-phase asynchronous motor is n=60f(1-s)/p, after changing the input frequency of the motor, and then changing the speed of the motor is the most thorough, most convenient and reliable way. The instantaneous current of the motor direct start is 6-8 times of the normal and stable operation, and the step-down start is 4-5 times, and the frequency conversion speed regulation will not exceed 1.5 times the rated current of the inverter, whether it is the impact on the power grid, or the adaptability of the equipment, its advantages are clear and clear.
2. Stepless speed regulation
Stepless speed regulation, is no grade and no step speed regulation, from zero speed start to speed, and from speed to zero speed, in one go, the speed curve is continuous, smooth and stable, which greatly adapts to the load inertia, improves the adaptability of multiple mechanical equipment to each other, improves the production power, greatly reduces the mechanical conflict, oscillation and noise, prolongs the life of the equipment, and reduces the maintenance cost. The output frequency of ordinary inverters is about 0.00Hz-400.00Hz, the frequency resolution is 0.01Hz, some reach 650.00Hz, and the output of high-frequency inverters can reach 5000Hz, which has completely covered all the scale of industrial speed regulation.
Before the birth of the inverter, we now have many mechanical speed regulation methods, which can be seen everywhere in our daily life, such as large and small gears, belts, reducers, etc., and these speed regulation methods can only output a fixed proportion of speed each time, and it is not so simple to change the speed frequently, of course, there are slip motor methods, but after all, the scale of use is limited, and the maintenance and cost are higher. With the presentation of central components such as transistors and microprocessor chips, we will promote a major breakthrough in stepless speed regulation technology. The birth of the inverter is the result of adapting to the needs of the level of industrial automation and the development of a number of related industries.
3. Frequency conversion function
In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, there is a certain amount of surplus. When the motor cannot run at full load, in addition to meeting the requirements of power drive, the excess torque adds the consumption of active power, forming a waste of electric energy. The traditional speed regulation method of fans, pumps and other equipment is to adjust the air volume and water supply through the baffle plate and valve opening of the inlet or outlet, and the input power is large, and a lot of energy is consumed in the interception process of the baffle and valve. When using frequency conversion speed regulation, if the flow requirement is reduced, the speed through the descending pump or fan can meet the requirements. Take the example of energy saving of fan pump load: a centrifugal pump motor has a power of 55 kilowatts, when the speed drops to 4/5 of the original speed, its power consumption is 28.16 kilowatts, saving 48.8%, and when the speed drops to l/2 of the original speed, its power consumption is 6.875 kilowatts, saving 87.5%.
The energy-saving function of the inverter has been widely used in various industrial and civil development days, especially when the inverter is used for square torque loads, such as fans, fans, pumps, and propeller loads, which are determined by the torque curve of such loads. At low speed, because the flow rate of the fluid is low, the load torque is very small, and with the increase of the motor speed, the flow rate increases, and the load torque and power are also increasing.
Fourth, equipment and self-maintenance function
As we all know, in the actual equipment operation process, there are often a variety of factors leading to a variety of faults and equipment damage, if you can carry out intelligent detection, and active alarm and maintenance, it will be very necessary, such as undervoltage, overvoltage, lightning, overload, load stall, temperature is too high, communication problems, electromagnetic disturbance, power supply phase loss, motor phase loss, load short circuit, grounding short circuit, etc., some problems are fatal, once presented, the consequences are unimaginable.
In the process of research and development, the inverter is mainly for the safety of the internal equipment of the inverter itself, and multiple tests and maintenance are added, such as the promised maximum current of the inverter module will generally not exceed 2 times of the rating, the temperature of the electrolytic capacitor is 85 °C, the electromagnetic compatibility design, etc., coupled with the detection and response of the load side (such as motor temperature detection and maintenance, instantaneous power failure without stopping, etc.), making today's inverter highly intelligent, not only to maintain its own safety and normal operation, It also greatly maintains the safe operation of the front and rear equipment.
5. Power factor compensation function
Reactive power not only adds line loss and equipment heating, but also the decline of power factor leads to the decline of active power of the power grid.
After using the frequency conversion speed regulation equipment, because of the effect of the internal filter capacitor of the frequency converter, the reactive power loss is reduced and the active power of the power grid is added.
6. Automatic control function
The control function of today's inverter is now very complete, and it can cooperate well with other control equipment and instruments to realize centralized real-time monitoring and control of systematic networking, such as cooperative DCS, PLC, sensors, HMI, CNC, host computer, servo drive, etc., which greatly improves the degree of automation of the production line, saves manpower and material resources, improves power, and reduces cost. For example, the inverter can have a variety of frequency given methods, such as digital setting, potentiometer, external analog (0-10V, 4-20mA), multi-section speed, PID and other methods, can be equipped with a variety of controllers, frequency instructions of response signals, remote/local control switching, convenient for a variety of control needs of users, and some companies have continuously launched a variety of professional special aircraft, for some subdivided professional users to carry out personalized customized development, integrated development, for users to save the troublesome selection of system compatibility problems, saving money.
Inverter is an important member of the field of industrial automation. With the rapid development of China's automated chemical industry, the product function and stability of China's inverter brand have surpassed many foreign brands in some aspects, and the market share of domestic brands has gradually increased.
|
More on that
|
Safety precautions for low-voltage soft lift - Reynolds
Precautions for low-voltage soft starters
For cooling purposes, the soft starter must be installed in a straight direction.
In order to ensure excellent heat dissipation, there should be room for the soft starter device.
Main circuit selection ...
|
|
Precautions for multiple motors in one inverter - Reynolds
Equipment selection
1. Inverter selection. When it comes to sizing, the first thing to consider is the operating conditions – whether one or more motors should be started or stopped at any time during the operation of the inverter.
If the motor does not need to be started at any time during the operation of the inverter, it may only be stopped or ...
|
|
Operating instructions for the Reynolds control panel
1. FUN button; Press the FUN button to enter the settings menu F00;
2. Press and hold the up button or down button to scroll to the code that needs to be set;
3. Press the FUN button to confirm at this moment, and adjust the entry parameters to the required value;
4. After the adjustment is completed, press the WR storage button, and then the panel will display the ...
|
|
Inverter breakdown factor – Reynolds
1. Overpressure leads to brake pipe breakdown.
The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the additional voltage, which is reflected in the DC voltage of the inverter DC bus.
Overvoltage alarm generally appears when the machine is shut down, and its main ...
|
|
Selection of large fan inverter in the factory - Reynolds
First, select from the inverter "software".
The reason why the factory chooses the inverter to work together with the fan is that it is hoped that the automation and intelligent design of the inverter technology can improve the speed regulation mode of the fan, and reduce the wasted energy consumption, which not only improves the wind efficiency.
|
|
What inverter to choose what occasion - Reynolds
We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter.
When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a ...
|
|
The heat dissipation method of Reynolds switching power supply
1. Transfer heat pipes for heat dissipation.
In many applications, the heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant heat pipe surface. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...
|
|
AC servo motor with inverter control method - Reynolds
Because the inverter and servo are different in performance and function, and the use is not very different, it is not possible:
1) In the case of speed control and torque control, the general frequency converter is not very high, and there are also frequency converters that are used to react signals in the upper position to form a closed loop.
|
|
Reynolds JJR5000 Series Soft Starter Manual
Reynolds JJR5000 series all-digital intelligent communication motor soft engine adopts power electronics skills, microprocessor skills and modern control theory skills, and is a new type of engine equipment at the current level. The product can limit the starting current of the asynchronous motor when it starts, and is widely used in electric fans, ...
|
|
Inverter power and box structure selection - Reynolds
First, the selection of inverter power
The system power is equal to the product of the inverter power and the motor power, and the system power is higher only when both are operating at a higher power. From the perspective of power, when selecting the power of the inverter, we should pay attention to the following points:
1) ...
|
|
The frequency of the frequency converter is given in a given way
The first way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps to complete the output frequency controllability? One of the first and foremost key points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
Reynolds permanent magnet synchronous motor solutions
The permanent magnet synchronous motor has high-efficiency motor drive performance, which can complete high-speed, high-precision, high-stability, fast-responding, high-efficiency and energy-saving motion control. Reynolds drives provide a vector control technology solution for permanent magnet synchronous motors.
...
|
|
How to control the torque of the inverter vector according to the system - Reynolds
A brief introduction to the progress of the inverter in terms of torque:
This function adds the output voltage of the inverter so that the output torque of the motor is proportional to the square of the voltage, so as to improve the output torque of the motor. Improve the skill of insufficient torque at low speed output of the motor, and use the "vector manipulation" ...
|
|
How to measure a frequency converter with a multimeter – Reynolds
How to use a multimeter to measure the quality of the inverter, it needs to be noted that for personal safety, it is necessary to ensure that the machine is powered off, and remove the inverter input power line R, S, T and output line U, V, W before operation! First of all, the multimeter is hit to the "secondary pipe" file, and then through the multimeter ...
|
|
Reynolds drives RNB1000 series fault code resolution
Reynolds inverter fault codes:
E.bC
Reynolds inverter fault phenomenon/type:
Brake unit failure
Reynolds inverter failure may be caused:
1. Brake line failure or brake ...
|
|
Reynolds assisted Sinopec Weirong shale gas project
With the rapid development of China's national economy, the supply and demand situation of oil and gas resources is becoming increasingly severe, and the import of oil and gas is increasing year by year, so it is urgent to expand the field of domestic oil and gas exploration and development. Strengthening the exploration and development of shale gas resources can make up for the lack of conventional oil and gas resources and promote the sustainability of the oil and gas industry.
|
|
Precautions for installation of Reynolds low-voltage inverters
One. Safety Precautions
1. First of all, it is necessary to have certain electrical professional knowledge, and understand the job site, understand the equipment status, and have certain electrical operation technology.
2. Determine the voltage level of the equipment (such as low-voltage AC380V) and whether it is low-voltage ...
|
|
Application misunderstandings and drawbacks of inverter and countermeasures - Reynolds
Misunderstanding: connect electromagnetic switches and electromagnetic contactors in the output circuit of the inverter
In actual use, some occasions require the use of contactors for frequency converter switching: such as when the frequency conversion is faulty, switch to the power frequency operation, or when the one-to-two method is adopted, a motor is faulty, and the variable frequency is used.
|
|
Progressive method of robustness of automatic control cabinets – Reynolds
1. Appropriate working environment
1. The ambient temperature is suitable
All manufacturers have certain rules for active temperature control cabinets. The PLC promises that the ambient temperature is usually about 0 to 55 ° C, so during the equipment process, this heating element is not placed in the PLC; The PLC should have adequate ventilation and ...
|
|
Method for measuring the quality of frequency converter modules – Reynolds
1. Test rectifier circuit:
To the P end and N end of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, the red watch rod is connected to P, and the black watch rod is separated from R, S, T, and there are tens of ohms of resistance in normal times, and it is basically balanced. Instead, connect the black watch rod to the P end, and the red watch stick will be ...
|
|