The Wiener bus system is reliable

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The bus refers to the connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices. The role of the busbar is to gather, distribute and transmit electrical energy.

                               The Wiener bus system is reliable

Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and gather and distribute electricity. The main conductor used by the power station or substation to transport electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is transported to individual users or other substations.

Electric is a global leader in power control, power transmission and distribution, emergency power systems, and industrial automation products and services.

Electrical performance improvement, installation process improvement, protection level improvement; Relying on its product strengths, Eaton is focused on changing the way of solutions and is committed to driving the steady development of affairs with technology innovation.

In addition, after passing the inspection, the Wiener bus has manufactured a VGS circuit breaker with regulating function (a structure is VGS) due to its own special requirements, in addition to its high-voltage system replacement device (i.e. transformer), the surface of the Wiener bus has the function of booster installation or commissioning.

The system adopts fluid transportation and hydraulic injection methods, which can effectively improve the mechanical strength of the pipeline. Even if there are special requirements, this method is not suitable for power lines of the original voltage level, and in addition, the small diameter of the pipe can be installed on high-precision machines with simple damage.
More on that
Wiener busway specification standard parameters Wiener busway specification standard parameters

1. The standard scale of the bus duct This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box). This specification specification applies to additional voltage AC to 660V...

What are the common types of fuses - Wiener What are the common types of fuses - Wiener

Plug-in fuse: It is commonly used at the end of the line at the voltage level of 380V and below, as a short-circuit maintenance for distribution branch lines or electrical equipment. Spiral fuse: The upper end of the melt is covered with a fuse indicator, once the melt is melted...

Structural characteristics of high-voltage busway - Vernal Structural characteristics of high-voltage busway - Vernal

If you understand the scope of application of the busway, you can see that the excellent effect of the busway has the upper hand, which has a lot to do with the structural features. Therefore, if you want to have more confidence with the bus duct, you still need to understand it from the structural characteristics. At a time when China's economy is developing rapidly, ...

Classification of busway – Vernal Classification of busway – Vernal

According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (without partition jacks and jacks), the L-shaped straight (horizontal) curve bus, the Z-shaped straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-shaped straight (horizontal) four-way bus, the transformer...

Wiener AC busbar system characteristics Wiener AC busbar system characteristics

The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...

Low-voltage enclosed busway function - Wiener Low-voltage enclosed busway function - Wiener

Phase-off bus is a kind of high-current transmission equipment widely used in the outgoing circuit of generators of 50MW and above and the branch circuit of the factory The phase-off busbar, conductor and shell are made of aluminum plate coil and welding, with the following characteristics: ...

Power system bus wiring features - Wiener Power system bus wiring features - Wiener

1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected. ...

Wiener busway plug-in box wiring method Wiener busway plug-in box wiring method

The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection. ...

What are the hazards of 220V DC in the bus system - Wiener What are the hazards of 220V DC in the bus system - Wiener

The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of DC are insulated from the ground, and there is no grounding current when generating a ground current when one pole is grounded.

A brief introduction to the classification of busway - Wiener A brief introduction to the classification of busway - Wiener

Busway (referred to as busway) is a busbar system composed of metal plates (steel plates or aluminum plates) to protect the shell, conductive bars, insulating materials and related accessories. It can be made into a plug-in closed bus with plug-in junction boxes at intervals, or as a feed-in type without a junction box in the center ...

Wiener is a common way to wiring busbars Wiener is a common way to wiring busbars

Single bus wiring method: all outgoing wires are connected to the same busbar, which is also the most cost-effective and simplest wiring method Single bus segmentation: The outgoing line is arranged in two parts on different sections of the single busbar, so that a power failure in the meantime does not affect the power supply of the other bus ...

The operation procedure of the dual power supply automatic transfer switch The operation procedure of the dual power supply automatic transfer switch

The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangements, intelligent controllers, etc., which are divided into two structures: integral and split.

The advantage of busway over cable in modern construction - Wiener The advantage of busway over cable in modern construction - Wiener

The power supply trunk of modern buildings plays a very important role like the aorta of the human body, and if something goes wrong, it can cause serious consequences. In the 80s of the 20th century, many stable cables were used in modern buildings. With the rapid development of the city, the power load of the building ...

220V DC Hazard in Busbar System – Wiener 220V DC Hazard in Busbar System – Wiener

The grounding of the DC system should include two conditions: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of DC are insulated from the ground, and they do not cause any harm when generating a ground current because there is no path to constitute a grounding current, but the ground of one pole is long.

NH-Fuse Type Disconnector Instructions for Use NH-Fuse Type Disconnector Instructions for Use

When switching on and off components, you should pay attention to the following: –In accordance with VDE-0105-100, only operation by electrical professionals or persons with electrical knowledge is allowed (operation without electricity, closing, disconnecting, and replacing fuses ...).

Types of busbars, conditions for the scope of application - Wiener Types of busbars, conditions for the scope of application - Wiener

1. Commonly used busbars, useful categories Busbars are divided into hard busbars and soft busbars. According to its different shapes, hard buses can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars and so on. Rectangular busbars are the most commonly used busbars and are also busbars. According to its material ...

Uses and characteristics of detached closed busbar - Wiener Uses and characteristics of detached closed busbar - Wiener

Closing busbars include out-of-phase shut-off buss, co-box (including co-box phase isolation) shut-off busbars and cable busbars, which are used for power plants, substations, industrial and civil power supply leads. Phase-off busbar 1. Usefulness Out of phase ...

What is the Wiener bus system What is the Wiener bus system

The Wiener bus system is a standardized system for bus spacing, which is used in low-voltage power supply and distribution switchgear, so that the bus can both conduct electricity and support electrical components. The system is divided into 40, 60, 100 and 185mm systems. ...

Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

Closed busway essentials – Wiener Closed busway essentials – Wiener

Before the closed busway device, it should be ensured that the electrical shaft, the transformer and distribution room, the decoration project of the place through which the busway passes, and the heating and ventilation project are all completed to ensure that the closed busway is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top