That's how Rosemount transmitters should be selected

Create Date: 2024-8-30 12:03:23|Source: Rosemount/Rosemount

Rosemount transmitter selection requires a good transmitter before use, so its selection is very important
That's how Rosemount transmitters should be selected

1. According to the pressure interface mode

Generally, threaded connection is the standard interface method.

2. According to the required accuracy level

The measurement error of the transmitter is divided according to the accuracy level, and different accuracy corresponds to different basic error limits. In practical application, the selection is made according to the control requirements of the measurement error and in line with the criterion of economic application.

3. According to the power supply and output signal

Generally, the pressure transmitter is powered by a DC power supply, and a variety of output signals are available.

4. According to the large overload of the system

The safe overload pressure of a typical pressure transmitter is 2 times the full scale. The overload maintenance of the transmitter should be greater than the larger overload of the system, otherwise it will affect the service life of the transmitter or even damage the transmitter.

5. According to the working temperature range of the system

The temperature of the measuring medium should be within the working temperature range of the transmitter, if the over-temperature application is used, a large measurement error will occur and affect the service life of the transmitter; In the case of high temperature, auxiliary cooling measures such as radiators and condenser pipes can be adopted or high-temperature pressure transmitters can be considered; In the production process of the pressure transmitter, the temperature influence will be compensated and measured to ensure that the measurement error caused by the temperature is within the range required by the accuracy level.

6. According to the on-site working environment and others

Whether there is vibration or electromagnetic interference, etc., in order to take appropriate treatment, relevant information should be provided at the time of selection.

The above is the rules for the selection of Rosemount transmitters introduced to us, through which you can better help you choose a good transmitter and let the transmitter give full play to its performance.

More on that
Rosemount Models 2088, 2090F, and 2090P Pressure Transmitters Quick Installation Guide Rosemount Models 2088, 2090F, and 2090P Pressure Transmitters Quick Installation Guide

1.Rosemount 2088   Install it directly to the impulse pipe without the need for an additional mounting bracket, or use the optional mounting bracket to mount it directly to a wall, panel, or 2" pipe. 2. Rosemount 2090P Use of existing welded short casings ...

Rosemount 3051 Pressure/Differential Pressure Transmitter Zero Point Adjustment Method Rosemount 3051 Pressure/Differential Pressure Transmitter Zero Point Adjustment Method

Rosemount differential pressure transmitter zero point adjustment   Before zeroing, admit that the balancing valve is nearly open, and use a flathead screwdriver to turn the zeroing screw. The clockwise conditioning output increases, the counterclockwise conditioning output decreases, and the zeroing resolution can reach 0.01% of the set range.

A method for verifying a current loop signal for a Rosemount pressure transmitter A method for verifying a current loop signal for a Rosemount pressure transmitter

The Rosemount pressure transmitter uses a 4-20mA signal, which is the conversion value of the output generated by the pressure transmitter. The output of the transmitter is detected according to the HART protocol, however, it is converted to a proportional current so that it can be visualized as a reading. Normally, at zero level output, the transmitter displays 4mA ...

Eight ways to maintain your Rosemount 3051 pressure transmitter Eight ways to maintain your Rosemount 3051 pressure transmitter

1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit. 2. When wiring, pass the cable through the waterproof joint or winding pipe and tighten the sealing nut to prevent rain from leaking through the cable.

The Rosemount Twisted Square thermowell avoids wake shedding The Rosemount Twisted Square thermowell avoids wake shedding

When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In some less complicated cases, it may be necessary to make a small change, such as adding one millimeter without changing the predetermined measurement orientation ...

Features of Rosemount pressure transmitters: Features of Rosemount pressure transmitters:

The main features of Rosemount pressure transmitters are as follows:   1. It has the function of converting high and low pressure side: The conversion function of the high and low voltage side of this sensor is mainly through the adjustment of the internal parameters of the handheld communicator, and the useful data on the high and low voltage side is realized.

Features of the Rosemount Transmitter 3051S Series High Precision Transmitters: Features of the Rosemount Transmitter 3051S Series High Precision Transmitters:

Features of the Rosemount Transmitter 3051S Series High Precision Transmitters: Advanced diagnosis Advanced diagnosis provides ongoing process monitoring to ensure the integrity and security of the process environment. The Statistical Process Monitoring (SPM) skill alerts you to deal with issues and anomalies. This comprehensive ...

Rosemount 3051S direct-attach pressure transmitter Rosemount 3051S direct-attach pressure transmitter

The Rosemount 3051S direct-attach pressure transmitter is a professional-class solution for optimized functionality. This scalable SuperModule™ platform reduces process variation and reduces protection, making it particularly useful for gauge and absolute pressure measurement in Rosemont transmitters. Should...

Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter

1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected. 2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be a straight pipe section of equal diameter of not less than 15D (D is the diameter of the pipe) in the upstream of the flowmeter, and there should be ...

Problems to be noted when calibrating Rosemount transmitters Problems to be noted when calibrating Rosemount transmitters

1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA. 2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.

The installation environment affects the use of Rosemount transmitters The installation environment affects the use of Rosemount transmitters

If you want to get better measurement results in practical applications, you need to pay attention to the following environmental issues when installing:   1. The Rosemount transmitter pressure impulse pipe should be arranged in a place where the temperature fluctuation is small, and the buffer tube (disk) should be connected when measuring steam or other low-temperature medium.

Types of Rosemount transmitters Types of Rosemount transmitters

The intelligent Rosemount transmitter is also equipped with a hand-held terminal (external data setter or grouper) for setting the transmitter parameters, such as setting the type of transmitter, range adjustment, zero point adjustment, input signal selection, output signal selection, engineering unit selection and damping time constant.

Features of the Rosemount 8732E Electromagnetic Flowmeter: Features of the Rosemount 8732E Electromagnetic Flowmeter:

1. The measurement is not affected by the change of fluid density, viscosity, temperature, pressure and conductivity. 2. There are no obstruction moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. There is a common adaptability to slurry measurement. 3. Reasonable selection of sensor lining and electrode materials, ...

Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements

For applications where the waveguide is completely submerged in liquids, the Rosemount 5301 measurement interface can be used, but the following guidelines should be followed 1. The dielectric constant of the above product must be known and cannot be changed. The Radar Master software has built-in dielectric constant calculations ...

How to solve the problem of Rosemount differential pressure transmitter migration failure How to solve the problem of Rosemount differential pressure transmitter migration failure

The migration of differential pressure transmitters is a form of application, which refers to the process of artificially moving the measuring point of a differential pressure transmitter from the zero point to the required value. The migration of differential pressure transmitters includes two major contents: positive migration and negative migration.

What is the difference between a Siemens transmitter and a Rosemount transmitter What is the difference between a Siemens transmitter and a Rosemount transmitter

Differences between Siemens transmitters and Rosemount transmitters: Siemens' transmitters are piezoresistive pressure transmitters, while Rosemount's transmitters are capacitive pressure transmitters. The transmitter converts the output signal of the sensor into other signals that can be recognized by the controller.

Rosemount transmitters feature two-way communication Rosemount transmitters feature two-way communication

The intelligent Rosemount transmitter is composed of a sensor and a microprocessor (microcomputer), which makes full use of the computing and storage capabilities of the microprocessor to process the data of the sensor, including the conditioning of the measurement signal (such as filtering, amplification, A/D conversion, etc.), data display, etc.

The Rosemount 3051 transmitter has its own advantages The Rosemount 3051 transmitter has its own advantages

1. The five-year stable soil is 0.125%, which can greatly reduce the cost of verification and protection. 2. Faster dynamic response, which can reduce the variability of the process. 3. The co-plane planning can realize a comprehensive measurement scheme. 4. Compact and lightweight coplanar planning with the best function ...

How to maintain the Rosemount 3051 pressure transmitter How to maintain the Rosemount 3051 pressure transmitter

United States rosemount 3051 pressure transmitter maintenance is mainly divided into two points:   1. In the whole process of accurate measurement, some common faults often occur in the Rosemount pressure transmitter, and the immediate judgment and analysis and resolution of common faults are especially important for the production and manufacturing that has been carried out.

Rosemount differential pressure transmitter selection considerations Rosemount differential pressure transmitter selection considerations

The following points should be considered in the selection of differential pressure transmitters: 1. Measure the scale, the accuracy of the demand and the measurement function; 2. Measure the environment of the outer surface, such as the industrial environment of petrochemical industry, the existence of flammable, toxic and explosive risk atmosphere, and the high ambient temperature; 3 tested ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top