Delixi's communication regulator is divided into single-phase communication regulator and three-phase communication regulator. Among them, the types of single-phase communication regulators are mainly TND, TND3, AVR, JJW-D, DBW and other types; The types of three-phase communication regulators are mainly SJW, JJW-S, SBW and so on.
Delixi's single-phase regulator and three-phase regulator are all voltage regulators, but the difference in use is quite large, different application scenarios need to choose the right regulator, can not be mixed.
The primary distinction and selection of single-phase communication regulators and three-phase communication regulators are as follows
1. The voltage is different
At present, the voltage we use is a single-phase 220V voltage and a three-phase 380V voltage, and the corresponding voltage regulator needs to choose Delixi's single-phase communication regulator and Delixi's three-phase communication regulator. The mains voltage, which is common in people's lives, is 220V voltage, and this voltage is a single-phase voltage, when the voltage is unstable, a single-phase communication regulator is required for voltage stabilization operation. The common voltage of industrial electricity is 380V, which is generally three front inputs, so it is also often referred to as three-phase electricity. In the case of unstable three-phase electric voltage, if it is necessary to stabilize the voltage, a three-phase regulator is required to stabilize the voltage.
2. Demand to select the right power
In terms of power, the single-phase regulator is within 100KVA, while the three-phase regulator is 4000KVA.
3. Different working scenarios and uses
Delixi single-phase voltage regulator is mainly used in homes and workplaces, is a tool for daily lighting, daily electrical appliances with electrical voltage stabilization; The Delixi three-phase communication voltage regulator is mainly used in industrial sites, is a special voltage regulator for industrial machinery voltage stabilization. Because these two regulators are used in different environments and have different service objectives, they cannot be mixed and cannot be mixed.
4. Different access lines
The access line of a single-phase regulator is a one-phase two-wire, i.e., one in front and one neutral. The access line of the three-phase regulator is a three-phase four-wire, that is, one neutral wire in front of the three. Correctly understand the difference between single-phase voltage regulator and Delixi three-phase communication voltage regulator, it is of great significance to the correct use of voltage regulator and protect the safety of electricity.
|
More on that
|
Transformer abnormal power-off treatment fault method - Delixi
First of all, when the transformer is faulty, we must cut off the power supply of the transformer through abnormal methods for the first time, and many major electrical fires and electric shocks are caused by the main gate is not closed. Now let's take a look at what to do.
...
|
|
Delixi circuit breaker accessory function
Varieties of circuit breaker accessories
It is divided into two categories: in-flight accessories and out-of-flight accessories.
The accessories in the machine are the subordinate equipment of the equipment inside the circuit breaker, including four types: shunt tripper, undervoltage tripper, auxiliary switch and alarm switch. Normally the in-flight accessories have to be uncovered with the device, but now ...
|
|
Precautions for the use of Delixi leakage protector
1. If the two branch lines are connected, the current in the zero line flows to each other, which destroys the operating current balance in the zero sequence current transformer and causes the leakage maintainer to malfunction. If you want to use the neutral line of the power branch line as the neutral line of the lighting branch line nearby, it will cause the leakage of the power branch line.
|
|
Delixi small contactor structure introduction
Delixi's communication contactor is widely used in industrial electrical, contactor as a kind of electromagnetic switch, its interior is mainly composed of the main and auxiliary contacts and electromagnetic coils, static cores and other parts of the control line connection and breaking.
...
|
|
AC contactor controls the forward and reverse rotation of the motor - Delixi
The forward rotation control of the asynchronous motor, the peers of the double contactor and the button are doing more, but is there anyone who will use an AC contactor to achieve the forward rotation control effect of the motor?
Practical application: general bench drill, letter ...
|
|
The difference between an isolation switch and a circuit breaker
The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position.
Isolate ...
|
|
Delixi solid state relay over AC contactor advantages
Delixi solid state relay and Delixi communication touch device are more used products, so what are the advantages of solid state relay compared to communication touch device, how should we choose when we can choose?
1. First of all, solid...
|
|
Thermal calculation of linear regulator - Delixi
Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is the same as the power accounting, which is purely the value of the output input voltage difference multiplied by the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...
|
|
Delixi inverter selection points
Variable-frequency Drive (VFD) is an electric power control equipment that uses frequency conversion skills and microelectronics skills to control and communicate motors by changing the frequency of the working power supply of the motor. The inverter is mainly composed of rectifier (communication to DC), filtering, inverter (DC to ditch) ...
|
|
The choice of Delixi miniature circuit breaker
(1) Type selection. Depending on the application, select different circuit breakers. Circuit breakers are generally divided into power distribution, lighting, motor maintenance, thyristor maintenance and leakage maintenance.
(2) Selection of the number of poles. It should be based on different installation environment conditions.
|
|
Introduction of low dropout linear regulator - Delixi
LDO, or low dropout regulator, is a low-dropout linear regulator that uses a transistor or field-effect transistor (FET) operating in its saturation region to subtract the excess voltage from the input voltage used to generate a conditioned output voltage.
...
|
|
The structure of the inverter - Delixi
The main circuit is the power conversion part that supplies the voltage regulation and frequency modulation power supply to the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the inverter that converts the DC of the voltage source into a communication inverter, and the filter of the DC loop is the capacitor. The current type is to convert the DC of the current source into a communication ...
|
|
Analysis of common problems of inverter - Delixi
1. Why does the maintenance function of the inverter operate when the clutch is connected to the load?
When the load is connected with a clutch, at the moment of connection, the motor changes sharply from the no-load condition to the area with a large slip rate, and the large current flowing through causes the inverter to trip over the current and cannot work.
...
|
|
Delixi inverter function introduction
1. If the impact on the power grid can be reduced, it will not cause the problem of excessive peak-to-valley difference.
2. It can speed up the controllable function, so as to speed up the smoothing according to the needs of users;
3. The abort method of the motor and equipment is controllable, so that ...
|
|
Circuit breaker control loop to reduce damage method - Delixi
1 Anatomy of the causes
The various causes of the burning of the control loop components of the unmanned station are analyzed and classified as follows:
· When the personnel on duty operate, the precautions are not well grasped or the operation is improper;
· The organization does not lock and close the operation when it is not stored in energy, and the auxiliary contact of the switch cabinet ...
|
|
Delixi bearing rust causes
1. The instantaneous high temperature in the grinding process will make the surface of the workpiece reach a molten state, and the steel surface will react with the oxygen in the air chemically, which will form a very thin (20-30nm) iron oxide film.
|
|
Delixi CDRA soft starter features
Delixi CDRA soft engine is a set of soft start, soft stop, light load, energy saving and multi-functional protection in one of the motor control equipment. This is a shock-free and smooth motor during the entire start-up process. According to the type, it can be divided into equipment type and comprehensive.
...
|
|
What are the main series of Delixi switches
1. The aesthetic slab adopts frameless large buttons and fluorescent grid planning, giving people a comfortable texture experience. The large-pitch flat panel is simple and useful, and is available in four colours: Funky White, Champagne Gold, Starlight Silver and Midnight Black.
2 ...
|
|
Delixi inverter load type
The correct choice of Delixi inverter is very critical to the normal operation of the control system. When selecting a frequency converter, it is necessary to fully understand the load characteristics driven by the frequency converter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan, water pump ...
|
|
After 12 years of political participation, Hu Chengzhong said frankly that he is most concerned about the livelihood of private enterprises
Since 2003, when he was first elected to the National People's Congress Committee, Hu Chengzhong, the current chairman of the executive president of Delixi Group, was re-elected as the National People's Congress Committee for two consecutive terms, and in 2018, he was once again elected as a representative of the people from all over the country.
|
|