AC contactor controls the forward and reverse rotation of the motor - Delixi

Create Date: 2024-8-30 12:03:23|Source: Delixi

The forward rotation control of the asynchronous motor, the peers of the double contactor and the button are doing more, but is there anyone who will use an AC contactor to achieve the forward rotation control effect of the motor?

                            AC contactor controls the forward and reverse rotation of the motor - Delixi

Practical application: Generally, the bench drill is trusted to be used by peers, and he is modified and added a function to become an active tapping machine. Device, starter, original three-phase button self-locking or three-phase knob switch one, contactor CJ10-20, travel switch two, LAX series can be. Why is the contactor so big? I'm going to use the secondary normally closed contacts on the left and right of it as the main contacts. The main circuit, after the three-phase switch, L2 directly into the motor, L1, L2 connected to the left and right main contacts of the contactor, cross split to the left and right auxiliary normally closed contacts. The motor wire, the U connection to the left and left normally closed contacts of the lower end of the contactor, and the auxiliary normally closed to the right and right of the lower end of the main contact of the W contactor. V is directly connected to L2 without contactor control.   Weld a touch rod that may tap an 8 mm screw as a travel switch on the dial of the bench drill, fix two travel switches on the edge of the dial, one travel switch when starting, and one travel switch when stopping.

Working principle: the knob switch is closed, the contactor does not move, the power supply enters the motor, and the other two phases also enter the motor through the auxiliary normally closed contacts on the left and right, and the motor rotates. Press the table drill feed handle, the spindle moves down the dial together, and when it reaches a certain direction, the touch rod on the dial pushes the travel switch, the contactor is engaged, the auxiliary normally closed disconnection, the main contact is closed, the phase sequence is exchanged, and the motor is energized and rotated. The dial rotates upwards from the main shaft, the bumper pushes the second travel switch, the contactor is powered off, and the motor rotates forward.

When manual transmission, as long as the feed handle and dial are completely relaxed, so that he does not follow the movement of the spindle and does not touch the two travel switches.

More on that
Working principle and function of thermal relay Working principle and function of thermal relay

Thermal relay is a maintenance appliance used for overload maintenance of electric motors or other electrical equipment and electrical lines. In the actual operation of the motor, if the machine is in abnormal condition or the circuit is abnormal, the motor will be overloaded, the motor ...

Delixi electrical components circuit breaker introduction Delixi electrical components circuit breaker introduction

What is a Circuit Breaker? What is the function of a circuit breaker? How to choose the right circuit breaker in the work? The circuit breaker is what we often call an air switch. Just like a dam that controls the release of water, when the sluice gate is opened, the flow of water is continuous, and when the sluice gate is lowered, it blocks the flow of water. ...

Delixi voltage regulator fault phenomenon and solution Delixi voltage regulator fault phenomenon and solution

Voltage regulator fault phenomena and their corresponding solutions Input phase loss - correctly input phase A, B, C phase, should be three-phase four-wire system or five-wire system The control circuit board is not working - the control circuit board is disconnected or damaged by itself. Repair or replace Control circuit board in the state of protection ...

The role of Delixi AC voltage regulator The role of Delixi AC voltage regulator

Delixi high-precision fully active AC voltage regulator uses linear integrated circuits to form a control system, controls the servo motor, drives the contact voltage regulator to actively regulate the voltage, and is equipped with delay, overvoltage, undervoltage and overcurrent maintenance functions. The product has high efficiency, the same input and output voltage waveforms, and the output ...

Regularly inspect the inverter steps and methods - Delixi Regularly inspect the inverter steps and methods - Delixi

When the VFD is viewed regularly, the power supply should be blocked, the operation of the VFD should be stopped, and the cover of the VFD should be removed. The first thing is to check the places that cannot be seen without downtime, or the places where it is difficult to find problems on a daily basis, as well as the inspection and adjustment of electrical characteristics. After blocking the VFD power supply, the main power ...

Ways to reduce the number of inverter repairs - Delixi Ways to reduce the number of inverter repairs - Delixi

Inverter is a very ubiquitous equipment in modern workshops, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, inverter, delay inverter ...

Delixi resistance quantifies the resistance exerted by the circuit to the flow of current Delixi resistance quantifies the resistance exerted by the circuit to the flow of current

We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). Regarding metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal. ...

Delixi three-phase circuit breaker classification Delixi three-phase circuit breaker classification

Delixi's three-phase circuit breaker is generally divided into three types, namely 3P, 3P+N and 4P. (1) Differences: 3P: Only three wirings are used for pure three-phase electrical equipment, which trips when there is no single-phase load to the ground or when there is a short circuit between phases; Otherwise, when a one-phase N-line load occurs, the N-line is disconnected ...

Damage and repair of internal electronic components of the inverter - Delixi Damage and repair of internal electronic components of the inverter - Delixi

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter). Middle...

Delixi's AC contactor selection Delixi's AC contactor selection

It is selected according to the type of load current in the circuit. AC loads should be selected AC contactors, DC loads should be DC contactors, assuming that the control system is mainly AC loads, DC motors or DC loads have a small capacity, AC contactors can also be used to control, but the contact of the ...

Delixi quasi-sine wave voltage regulator application Delixi quasi-sine wave voltage regulator application

There are also several types of quasi-sine waves, ranging from square waves, which are almost indistinguishable from square waves, to rounded trapezoidal waves, which are relatively close to sine waves. We're only going to talk about square waves, which are the waveforms that most commercially available high-frequency regulators can supply today. ...

Thermal calculation of linear regulator - Delixi Thermal calculation of linear regulator - Delixi

Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is the same as the power accounting, which is purely the value of the output input voltage difference multiplied by the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...

Delixi inverter common problems Delixi inverter common problems

1. The pressure of Delixi inverter system is unstable and simple vibration? Answer: The pressure of the system is unstable, which may be due to the following reasons: A. There is a problem with the orientation of the pressure of the pressure sensor collection system, the pressure collection point is too close to the water pump outlet, and the pipeline pressure is affected by the water outlet ...

How to adjust the output voltage of Delixi voltage regulator How to adjust the output voltage of Delixi voltage regulator

1. How to disassemble the voltage regulator Generally, there are screws on the shell of the voltage regulator, please disconnect the power supply first, and then remove all the screws on both sides to take off the shell. After the regulator shell is disassembled, the circuit, copper coil, carbon brush, etc. inside will be revealed.

Delixi parameter voltage regulator performance and advantages Delixi parameter voltage regulator performance and advantages

1. Its overall inductive skills function is the best, its design does not use electronic equipment, and the environmental adaptability and stability and reliability function are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...

Delixi inverter in the die-casting machine frequency conversion energy-saving transformation Delixi inverter in the die-casting machine frequency conversion energy-saving transformation

First, the principle of energy saving The die-casting machine is a typical periodic variable load equipment, and a complete production cycle includes the stages of mold clamping, injection, cooling, and mold opening and ejection. Usually the power of hydraulic equipment is supplied by a quantitative oil pump, and the motor that drives the oil pump to work has always been rated for its ...

The choice of Delixi miniature circuit breaker The choice of Delixi miniature circuit breaker

(1) Type selection. Depending on the application, select different circuit breakers. Circuit breakers are generally divided into power distribution, lighting, motor maintenance, thyristor maintenance and leakage maintenance. (2) Selection of the number of poles. It should be based on different installation environment conditions.

The principle and operation method of Delixi inverter operation The principle and operation method of Delixi inverter operation

  The principle and operation method of Delixi inverter: 1. No-load energizing test of inverter 1. Ground the grounding terminal of the inverter. 2. Pass the power input terminal of the inverter through the leakage maintenance switch.

General parameter setting skills of inverter - Delixi General parameter setting skills of inverter - Delixi

The setting menu of the inverter is divided into a first-level menu, a second-level menu, etc., and the menu is followed by parameters. If the inverter starts in standby (ready to run) condition, set the FUn-PSS-SP2 parameter to 15Hz, and then return to the standby state operation. In the practice setting ...

Attention to the wiring of the inverter ground wire - Delixi Attention to the wiring of the inverter ground wire - Delixi

1. Because there is leakage current in the inverter, in order to prevent electric shock, it is necessary for the inverter and the motor to be grounded. 2. Special grounding terminal for inverter grounding. To connect the grounding wire, use tinned crimp terminals. When tightening the screws, be careful not to break the screws. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top