Introduction of low dropout linear regulator - Delixi

Create Date: 2024-8-30 12:03:23|Source: Delixi

LDO, or low dropout regulator, is a low-dropout linear regulator that uses a transistor or field-effect transistor (FET) operating in its saturation region to subtract the excess voltage from the input voltage used to generate a conditioned output voltage.

                           Introduction of low dropout linear regulator - Delixi

1. The four major elements are: dropout, noise, PSRR, and quiescent current Iq

2. Primary components: start-up circuit, constant current source bias unit, enable circuit, trimming element, reference source, error amplifier, reaction resistor network and maintenance circuit, etc.

3. Operating principle

LDO basic circuit by series adjustment tube VT, sampling resistor R1 and R2, comparison amplifier A composition system power-up, if the enabling pin is at a high level, the circuit starts to start, the constant current source circuit to the whole circuit supply bias, the reference voltage is quickly established, the unconditioned input voltage as the voltage of the power supply, the reference voltage as the negative phase input voltage of the error amplifier, the resistance response network will divide the output voltage and obtain the reaction voltage, the reaction voltage input to the error comparator in the same direction, Compare with a negative reference. The two voltage differences are amplified by the error amplifier and directly control the gate of the power adjustment element, and the output of the LDO is controlled by changing the conduction condition of the adjustment tube, that is: Vout=(R1+R2)/R2 ×Vref

Practical low-dropout linear regulators also have other functions such as load short-circuit maintenance, overvoltage shutdown, thermal shutdown, reverse polarity maintenance, and more.

More on that
The reason for the instability of the voltage regulator output - Delixi The reason for the instability of the voltage regulator output - Delixi

It shows that the voltage regulator base is not voltage corrected, and the voltage regulator in this situation is like a transformer, the higher the input voltage, the higher the output voltage, the input decreases and the output voltage also decreases. This...

Delixi indicator light failure and solutions Delixi indicator light failure and solutions

1. What should I do if the indicator light is on and when it is dark Generally, the reason for this situation is that the line contact is poor or the screws of the terminal are not tightened, we should check the condition of the line, connect the power cord and tighten the screws, and press the wire. ...

Delixi electrical components circuit breaker introduction Delixi electrical components circuit breaker introduction

What is a Circuit Breaker? What is the function of a circuit breaker? How to choose the right circuit breaker in the work? The circuit breaker is what we often call an air switch. Just like a dam that controls the release of water, when the sluice gate is opened, the flow of water is continuous, and when the sluice gate is lowered, it blocks the flow of water. ...

Delixi switching regulator basics Delixi switching regulator basics

1. What is a switching regulator? Switching regulator, English (regulatior), some people call it a regulator, a voltage regulator source. To achieve voltage regulation, it is necessary to control the system (negative feedback), from the theory of automatic control, we know that when the voltage rises, it is lowered by negative feedback, ...

What are the main series of Delixi switches What are the main series of Delixi switches

1. The aesthetic slab adopts frameless large buttons and fluorescent grid planning, giving people a comfortable texture experience. The large-pitch flat panel is simple and useful, and is available in four colours: Funky White, Champagne Gold, Starlight Silver and Midnight Black. 2 ...

Delixi E series inverter common fault analysis Delixi E series inverter common fault analysis

Fault phenomenon, fault description, detailed description of troubleshooting measures No display at power-on, no display, no display Check whether the power wiring is correct; Check whether the 5V power supply is normal; Check whether the keyboard is in good contact with the control board; Check whether the control panel and keyboard are normal. If you use ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.), in order to complete the control or maintenance mission.

Reducer troubleshooting method - Delixi Reducer troubleshooting method - Delixi

01 "O" ring spell In addition to the oil seal problem of the reducer itself, the robot manufacturer will also have an impact on the planning and installation of the reducer components, due to the sealing of the reducer, in addition to the oil seal, there are also O-rings. O-rings are a very common type of product sealing planning.

The structure of the inverter - Delixi The structure of the inverter - Delixi

The main circuit is the power conversion part that supplies the voltage regulation and frequency modulation power supply to the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the inverter that converts the DC of the voltage source into a communication inverter, and the filter of the DC loop is the capacitor. The current type is to convert the DC of the current source into a communication ...

Thermal calculation of linear regulator - Delixi Thermal calculation of linear regulator - Delixi

Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is the same as the power accounting, which is purely the value of the output input voltage difference multiplied by the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...

Classification of low-voltage electrical appliances - Delixi Classification of low-voltage electrical appliances - Delixi

1. Classified according to the operating voltage level Low-voltage electrical appliances: electrical appliances used to communicate circuits below 1200V and DC 1500V to play the role of on/off, protection, control or regulation. High-voltage electrical appliances: communication 1200V or more, DC 1500V or more. ...

Delixi time control switch adjustment Delixi time control switch adjustment

First, press the "Cancel Recovery Button" 4 times in a row; Then adjust the clock (the factory has been adjusted), if you need to adjust it again, press and hold the "clock key" together, and then press the "school week, time key, school minute key" to adjust the Beijing time. ...

Leakage protector leakage cause - Delixi Leakage protector leakage cause - Delixi

1. Poor device If the terminal posts of the leakage protector are not firmly connected during the installation, it will often lead to the heating and oxidation of the terminal post for a long time, so that the wire insulation layer will be scorched, and accompanied by the smell of ignition and rubber and plastic burning, forming an undervoltage of the line and tripping the leakage protector. ...

Delixi inverter fault maintenance Delixi inverter fault maintenance

Delixi inverter is a commonly used inverter, how to maintain in the event of failure?   Constant speed overcurrent: When the inverter is running at a constant speed, the output current exceeds the current value. Check whether the output circuit of the inverter is short-circuited. Check if the input voltage is low. Examine...

Servo motor failure and analysis - Delixi Servo motor failure and analysis - Delixi

1. Motor encoder alarm 1. The cause of the failure (1) Wrong wiring; (2) electromagnetic disturbance; (3) Encoder hardware damage caused by mechanical vibration; (4) Pollution caused by the on-site environment. 2 ...

Delixi takes you to understand the knowledge of resistance and resistivity Delixi takes you to understand the knowledge of resistance and resistivity

1. Resistance Indicates the magnitude of the conductor's resistance to the current. Conversion between units of resistance: 1KΩ=1000Ω R indicates the resistance, and the unit of resistance is: ohms (Ω) R=U/I U--- voltage (unit: volts V) I--- current (in ...

The difference between Delixi voltage regulator SBW and SJW The difference between Delixi voltage regulator SBW and SJW

What is the difference between Delixi voltage regulator SBW and SJW, which is better? Customer Question: I maintain an uninterruptible power supply and a computer server, and the whole community shares a transformer, so the voltage fluctuation may be greater during the day and at night.

Delixi general inverter E100 series products introduction Delixi general inverter E100 series products introduction

E100 series products are a standard inverter with optimized open-loop vector control, V/F control, stable performance, rich functions, optimized structural design, exquisite appearance, and high cost performance. Technical features: ...

Prevent damage to the inverter - Delixi inverter Prevent damage to the inverter - Delixi inverter

1. Check and tighten all terminals to prevent serious heating caused by loosening. 2. Conduct a comprehensive view of the input (including output) terminal, rectifier module, inverter module, DC capacitor and fast-melting devices, and the parameters ...

How to select Delixi voltage regulator How to select Delixi voltage regulator

1. For pure resistive loads such as incandescent lamps, resistance wires, electric furnaces and other equipment, the power of the voltage regulator should be 1.5 times the power of the load equipment - 2 times that of the load equipment, for example, if your electric furnace is about 250W, you can choose a voltage regulator with a power of 500W. 2. Rationality ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top