Delixi solid state relay and Delixi communication touch device are more used products, so what are the advantages of solid state relay compared to communication touch device, how should we choose when we can choose?
1. First of all, the solid state relay has a long life and strong reliability. SSR solid state relay corresponding to Delixi is CDG1 series, this solid state relay has no mechanical parts, there is a solid device end contact function, because there is no movement of parts, so it can work in a high shock, vibration environment, due to the inherent characteristics of the components that make up the solid state relay, determines the long life of the solid state relay, high reliability. The communication toucher is through the coil to control the magnet to touch or disconnect the contact, which will cause the contact to be poor and other failures to incinerate the toucher after a long time.
2. The solid-state relay has good sensitivity, small control power and good electromagnetic compatibility. Solid state relays have a wide input voltage range, low drive power, and are compatible with most logic integrated circuits without the need for buffers or drivers.
3. Rapid conversion of solid-state relays. Due to the use of solids, the switching speed of solid-state relays can be from a few milliseconds to a few subtleties, and the conversion speed is very fast; The engagement of the communication toucher is controlled by a coil, so the conversion speed is in a few tenths of a second, which is slower than that of a solid state relay.
4. The electromagnetic disturbance of the solid-state relay is small. Since the solid state relay has no input coil, no touch arcing and no bounce, electromagnetic turbulence is reduced. Most AC output solid state relays are a zero-voltage switch that turns on at zero voltage and turns off at zero current, reducing abrupt interruptions in the current waveform and then reducing switching transient effects. The electromagnetic disturbance of the corresponding toucher is greater.
5. Solid state relays are smaller in size, while touchers are large in size. In some places where the space is relatively narrow, it may not be very convenient to install a touch device, so a solid state relay is needed; However, the solid state relay current is generally not very large, while the touch device current can achieve a large amperere.
6. There are various varieties of voltage conversion of solid-state relays, such as communication to communication, communication to DC, DC to DC, etc.; Touchphones are not so responsive and changeable.
|
More on that
|
Classification of low-voltage electrical appliances - Delixi
1. Classified according to the operating voltage level
Low-voltage electrical appliances: electrical appliances used to communicate circuits below 1200V and DC 1500V to play the role of on/off, protection, control or regulation.
High-voltage electrical appliances: communication 1200V or more, DC 1500V or more.
...
|
|
Delixi three-phase circuit breaker classification
Delixi's three-phase circuit breaker is generally divided into three types, namely 3P, 3P+N and 4P.
(1) Differences:
3P: Only three wirings are used for pure three-phase electrical equipment, which trips when there is no single-phase load to the ground or when there is a short circuit between phases; Otherwise, when a one-phase N-line load occurs, the N-line is disconnected ...
|
|
Delixi inverter EM60 series model introduction
S1 (Single-phase 110V, 50/60HZ)
CDI-EM60G0R75S1 0.75KW
CDI-EM60G1R5S1 1.5KW
S2 (Single Phase 220V, 50/60HZ)
CDI-EM60G0R4S2 (without built-in brake unit) 0.4KW
CDI-EM60G0R4S2B (Built-in ...
|
|
The role of Delixi AC voltage regulator
Delixi high-precision fully active AC voltage regulator uses linear integrated circuits to form a control system, controls the servo motor, drives the contact voltage regulator to actively regulate the voltage, and is equipped with delay, overvoltage, undervoltage and overcurrent maintenance functions. The product has high efficiency, the same input and output voltage waveforms, and the output ...
|
|
Switching power supply FAQ - Delixi
1. The safety wire is blown off
In a general environment, a blown safety wire indicates that there is a problem with the internal wiring of the power supply. Because the power supply is operated in the shape of high voltage and high current, the fluctuation of the grid voltage and the surge city cause the current in the power supply to increase suddenly and cause the safety wire to be blown off. The focus should be on checking the power ...
|
|
Delixi CDF1 isolation switch introduction and the difference with the transfer switch
Delixi CDF1 load isolation switch, the product material is carefully selected, with the advantages of reliability and durability. At the same time, it is locked when the power is on, and it can only be turned on when the power is off, which effectively avoids the occurrence of electric shock accidents.
The contacts are made of high-quality copper ...
|
|
Delixi leakage protector tripping causes and solutions
1. The leakage protector does not match the load. This situation mostly occurs when using high-power electrical appliances, and it is generally only necessary to replace the leakage protector that matches the practical needs from scratch.
2. Check whether the switch wiring is correct, ...
|
|
The reason for the heat and heat of the switch socket in Delixi
1. The socket quality is low quality
First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...
|
|
Installation steps of motor protector - Delixi
1. According to the requirements of the device part and the needs of the maintenance function, reasonably select the motor maintainer model and its various maintenance action parameter settings;
2. According to the requirements of the product operation manual, the correct device should be connected correctly according to the use of each terminal, and the operating power supply should be connected to the control ...
|
|
AC contactor controls the forward and reverse rotation of the motor - Delixi
The forward rotation control of the asynchronous motor, the peers of the double contactor and the button are doing more, but is there anyone who will use an AC contactor to achieve the forward rotation control effect of the motor?
Practical application: general bench drill, letter ...
|
|
The role of Delixi inverter
1. It can reduce the impact on the power grid, and there will be no problem of excessive peak-to-valley difference.
2. It can speed up the controllable function, and then speed up the slipping according to the needs of the user;
3. The abort mode of the motor and equipment is controllable, ...
|
|
Delixi time control switch adjustment method
Press the undo function key first, then press and hold the school time function key, then adjust the time and date to the current moment, press the punctual function key again, adjust the time that needs to be closed and open to the specified value, if you need to set multiple groups, then press the punctual function key to set, without multiple groups ...
|
|
Delixi built-in bypass soft starter CDRA-K3 series features
1. A variety of starting methods
Current limiting soft start, voltage ramp soft start, ramp plus current limiting soft start.
2. High reliability
Signals in the control system are digitized by high-performance microprocessors.
...
|
|
Delixi inverter E180 series technical features
1. Superior performance
The new vector control algorithm is adopted, and the starting cabinet is large, the torque response is fast, and the control accuracy is high, which further improves the operation efficiency of the motor.
2. Powerful function and low cost of use
Built-in large number of ...
|
|
Delixi circuit transformation attention to detail
1. If strong electricity and weak electricity are to be separated by a long distance from the horizon walking line, the interval should generally exceed 30 cm to prevent disturbance and be interspersed with each other.
2. In order to facilitate the future line change, the PVC pipe must be cut down and straightened as much as possible.
|
|
Delixi small contactor structure introduction
Delixi's communication contactor is widely used in industrial electrical, contactor as a kind of electromagnetic switch, its interior is mainly composed of the main and auxiliary contacts and electromagnetic coils, static cores and other parts of the control line connection and breaking.
...
|
|
Delixi's AC contactor selection
It is selected according to the type of load current in the circuit. AC loads should be selected AC contactors, DC loads should be DC contactors, assuming that the control system is mainly AC loads, DC motors or DC loads have a small capacity, AC contactors can also be used to control, but the contact of the ...
|
|
Delixi circuit breaker product characteristics classification
The function of Delixi circuit breaker is to make the circuit breaker internal electromagnetic tripping when the electrical equipment produces short circuit, overload, etc., resulting in the circuit breaker disconnecting the power supply, and maintaining the safety of electrical equipment and personnel.
When the electrical equipment is running, the circuit may produce abnormalities, which is the demand circuit breaker in the ...
|
|
Damage and repair of internal electronic components of the inverter - Delixi
1. Repair the damage of the inverter rectifier block
The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter).
Middle...
|
|
Delixi molded case circuit breaker external two tripping wire connection
The molded case circuit breaker tripper is divided into undervoltage tripper and shunt tripper. This article explains the wiring method of the circuit breaker with sub-excitation tripper. The shunt tripper is often used as an additional accessory for the user, it is a remotely operated circuit breaker disconnection device, installed in the molded case circuit breaker, when the shunt ...
|
|