Delixi inverter speed parameters

Create Date: 2024-8-30 12:03:23|Source: Delixi

There are two speeds of Delixi inverter, one is the target speed, and the other is the speed of practice.

The target speed requires the value of the detailed parameters to be adjusted, such as the *** high frequency/*** high frequency in the inverter parameters; Regarding the practical output speed, it is necessary to check the detailed settings of the frequency command source in the inverter parameters. It can pass through the potentiometer or the up/down buttons on the control panel.

                          Delixi inverter speed parameters

The parameters of the Speed Manipulator include the following aspects:

(1) Gain Parameter: The proportional gain of the velocity manipulator. If the gain is too large, it may cause the speed to fluctuate.

(2) Integration time parameter: The integration time of the speed manipulator, that is, the rate of change of the output signal of the manipulator under the error step signal. The shorter the integration time, the faster the correction of successive error values, but if the integration time is too short, it will lead to unstable control.

(3) Differential time parameter: The differential time of the velocity manipulator is to add the output of the manipulator when the error value changes. The longer the differentiation time, the faster the manipulator outputs during error changes. Differentiation makes the manipulation more sensitive to perturbations.

(4) Acceleration compensation differential moment: During acceleration, in order to compensate for inertia, a given change in the differential is added to the output of the velocity manipulator.

(5) Slip gain: The slip gain of the motor slip compensation control. Indicates full slip compensation, 0% indicates zero slip compensation.

More on that
The cascade protection of Delixi circuit breaker The cascade protection of Delixi circuit breaker

In the design of Delixi power distribution system, the selective cooperation between the upper and lower levels of the circuit breaker must have "selectivity, rapidity and sensitivity". Selectivity is related to the cooperation of the upper and lower circuit breakers, and the speed and sensitivity are related to the maintenance of the characteristics of the appliance itself and the way the line operates ...

Delixi circuit breaker mechanism spring design Delixi circuit breaker mechanism spring design

The spring is a widely used component in the circuit breaker mechanism, and the critical spring has a great impact on the function of the circuit breaker. From the perspective of energy, combined with the installation space of the tension spring, the author uses the existing accounting formula of the tension spring to solve the unknown quantity from the known quantity to obtain the required tension spring parameters.

Delixi contactor common faults Delixi contactor common faults

After long-term use or too frequent movements, or improper daily maintenance, problems may occur during operation and affect the normal operation. Frequently asked questions are as follows: 1. Coil problem The first problem with the coil is because of the ...

What are the main series of Delixi switches What are the main series of Delixi switches

1. The aesthetic slab adopts frameless large buttons and fluorescent grid planning, giving people a comfortable texture experience. The large-pitch flat panel is simple and useful, and is available in four colours: Funky White, Champagne Gold, Starlight Silver and Midnight Black. 2 ...

Debugging method of servo motor - Delixi Debugging method of servo motor - Delixi

First: Initialize the parameters Before wiring, initialize the parameters. On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enabling signal is turned off by default; Save this status to ensure that this is the condition when the control card is powered on again. The servo motor ...

Delixi rangefinder analysis Delixi rangefinder analysis

Delixi Group focuses on low-voltage power distribution and industrial automation in the field of comprehensive solutions suppliers, founded in 1984, is a collection of industrial operations, brand operations, capital operations as one of the large enterprise groups, for 18 consecutive years ranked among the top 500 Chinese enterprises. Delixi rangefinder is designed for ...

Delixi occasion to choose the inverter Delixi occasion to choose the inverter

We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter. When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a reference. Secondly, the output of the inverter should be fully considered ...

How to solve the data running flight of Delixi inverter controller How to solve the data running flight of Delixi inverter controller

Problem depiction: Delixi inverter controller data flying, or the data is occasionally incorrect, how to solve? Solution(s): This is the result of severe disturbances to the controller. Frequently...

The difference between Delixi LDO and DC-DC The difference between Delixi LDO and DC-DC

The so-called DC-DC is actually DC to DC voltage, of course, LDO is also a kind of DC-DC, and only LDO can only achieve step-down. The general DC-DC is mainly converted from DC to AC communication through the self-excited vibration circuit inside, so the external inductance and capacitor are required to achieve LC vibration (and LDO is only ...

Delixi inverter installation and wiring Delixi inverter installation and wiring

1. The device of the inverter 1.1 The device environment requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions requiring no direct sunlight, no corrosive gas and flammable gas, less dust, ...

Delixi inverter built-in bypass soft starter CDRA-K3 Delixi inverter built-in bypass soft starter CDRA-K3

Delixi built-in bypass soft starter CDRA-K3 series is a set of soft start, soft parking and multi-functional protection in one of the motor control equipment. Realize a smooth starter motor without impact during the entire starting process. CDRA-K3 series has built-in bypass contactor and control power supply.

The reason for the unstable pressure of Delixi inverter system The reason for the unstable pressure of Delixi inverter system

Problem Description: The pressure of Delixi inverter system is unstable, simple vibration? Solution(s): The pressure of the system is unstable, which can be due to the following reasons: A. The position of the pressure sensor to collect the pressure of the system is ...

Judgment and treatment of inverter short-circuit fault characteristics - Delixi Judgment and treatment of inverter short-circuit fault characteristics - Delixi

(1) Fault characteristics a) The first trip may occur during operation, but if it is restarted after resetting, it will often trip as soon as the speed is raised. b) have a large inrush current, but most drives are now able to perform maintenance trips without damage. Due to the ...

Introduction to the closed-loop control system of stepper motor Introduction to the closed-loop control system of stepper motor

1. The closed-loop control of the stepper motor was first in the form of encoder For stepper motors with low split ratio, a slotted disc and photoelectric sensor are usually used as a reaction encoder assembly, and the number of notches is equal to the number of steps taken by the motor per revolution, · About high resolution ...

Reduce the maintenance cost of the inverter - Delixi Reduce the maintenance cost of the inverter - Delixi

Frequency converter is a widely used equipment in modern factories. This is a very expensive new type of equipment, and the maintenance price of the inverter is also very expensive, so in the process of using the inverter, we should pay attention to the use of the inverter. Thing...

Delixi inverter installation and wiring Delixi inverter installation and wiring

1. The environmental requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions that require no direct sunlight, no corrosive gas and flammable gas, less dust, and an altitude of less than 1000m. ...

Delixi circuit transformation attention to detail Delixi circuit transformation attention to detail

1. If strong electricity and weak electricity are to be separated by a long distance from the horizon walking line, the interval should generally exceed 30 cm to prevent disturbance and be interspersed with each other. 2. In order to facilitate the future line change, the PVC pipe must be cut down and straightened as much as possible.

Delixi inverter harmonic control method principle analysis Delixi inverter harmonic control method principle analysis

1. Install AC reactor and DC reactor. When the inverter is used in the distribution transformer capacity is greater than 500kva, and the transformer capacity is greater than 10 times of the inverter capacity, an AC reactor is installed on the input side of the inverter. And when the output voltage of the distribution transformer is unbalanced and uneven in three phases ...

Voltage regulator failure and solution - Delixi Voltage regulator failure and solution - Delixi

1. There is no output, no voltage indication or no start when the machine is turned on. Overvoltage or undervoltage maintenance 1. Adjust the internal output voltage adjustable potentiometer 2. The wrong phase and the lack of phase are maintained, and the two phases are arbitrarily replaced by three phases 3. The main control circuit board is broken 3. Replace 4. The output AC has been ...

Delixi molded case circuit breaker Icu=ICS understands Delixi molded case circuit breaker Icu=ICS understands

Delixi 3P air switch, rated current 630A, rated voltage 380V. The Icu=Ics=70kA of this circuit breaker. When the short-circuit current reaches 70kA, can the circuit breaker still be used? If it works, the ICU is already at its limit, which is a contradiction. If it can't be used, ICS is 70KA, which means ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383