Delixi low-voltage AC contactor can not be suction reason

Create Date: 2024-8-30 12:03:23|Source: Delixi

Although this is not a common problem of AC contactors, the failure of AC contactors to engage will affect the efficiency of operation and even damage the production equipment.

What if the solenoid coil causes a pick-up problem? Delixi Electric teaches you to test, assuming that the test results are the existence of additional voltage, but the additional voltage and the parameters of the electromagnetic coil have a certain distance, usually means that the electromagnetic coil may present a problem, assuming that the additional voltage exists, and the same as the low-voltage AC contactor parameter specification, most of the problems caused by the electromagnetic coil, perhaps the need to replace the electromagnetic coil to be able to deal with the suction problem.

                              Delixi low-voltage AC contactor can not be suction reason

What should I do if the control loop causes a suction problem? Under normal circumstances, when looking for a problem with the low-voltage AC contactor equipment, the corresponding tools need to be prepared, and the homework that needs to be done is to test both sides of the electromagnetic coil, if the test result is that there is no additional voltage, it means that the cause of the problem is closely related to the control loop, and you can check whether the control loop is faulty. Defects in the control circuit and solenoid coil usually lead to the engagement of the low-voltage communication contactor, so it is important to always check the equipment components and perform excellent maintenance work on the low-voltage communication contactor.

To sum up, assuming that the Delixi communication contactor presents a situation that cannot be sucked, it is comprehensively investigated from the following conditions:

1. The contactor coil is broken

2. Check whether the power supply voltage reaches more than 85% of the additional voltage, which is the minimum requirement for the contactor coil suction voltage

3. Check whether the applicable voltage level of the contactor coil corresponds to the power supply, and see whether the voltage is 220V or 380V

4. Check whether the power supply is communication or DC

5. Check whether the power switch is turned on and whether the starting circuit is open

More on that
The component of the main line of the inverter - Delixi The component of the main line of the inverter - Delixi

An inverter is usually a device that replaces a constant voltage and frequency with a constant voltage or frequency for a variable voltage. However, in the application, the inverter will inevitably present shortcomings, and when analyzing the shortcomings of the problem, in order to deal with the shortcomings well and quickly, ...

Delixi resistance quantifies the resistance exerted by the circuit to the flow of current Delixi resistance quantifies the resistance exerted by the circuit to the flow of current

We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). Regarding metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal. ...

Advantages of Delixi parameter voltage regulator Advantages of Delixi parameter voltage regulator

1. Its overall induction skills are the best, its design does not use electronic devices, and the environmental adaptability and stability are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...

Delixi relays and precautions Delixi relays and precautions

Quickness: It means that the maintenance device should be able to remove the short circuit as soon as possible, and its intention is to improve the stability of the system, reduce the damage to the peak equipment and lines, reduce the scope of the process, and improve the effect of active overlapping room and standby power supply or standby equipment active investment. ...

The difference between an isolation switch and a circuit breaker The difference between an isolation switch and a circuit breaker

The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position. Isolate ...

Delixi inverter E180 series technical features Delixi inverter E180 series technical features

1. Superior performance The new vector control algorithm is adopted, and the starting cabinet is large, the torque response is fast, and the control accuracy is high, which further improves the operation efficiency of the motor. 2. Powerful function and low cost of use Built-in large number of ...

Precautions for the use of Delixi leakage protector Precautions for the use of Delixi leakage protector

1. If the two branch lines are connected, the current in the zero line flows to each other, which destroys the operating current balance in the zero sequence current transformer and causes the leakage maintainer to malfunction. If you want to use the neutral line of the power branch line as the neutral line of the lighting branch line nearby, it will cause the leakage of the power branch line.

Precautions for leakage vacuum circuit breaker circuit - Delixi Precautions for leakage vacuum circuit breaker circuit - Delixi

Leakage vacuum circuit breaker connection: When normal operation, regardless of whether the three-phase load is balanced or not, the sum of the three-phase current phasor through the main circuit of the zero-sequence current transformer is equal to zero, so there is no induced electromotive force in the secondary winding, and the leakage maintainer operates in a closed state. In the event of leakage or ...

Fault analysis of commonly used voltage electrical appliances - Delixi Fault analysis of commonly used voltage electrical appliances - Delixi

1. Voltage circuit breaker problem The contact is overheated, you can smell the power distribution control cabinet, by checking that the moving contact is not completely inserted into the static contact, and the contact pressure is not enough, resulting in a decrease in the switching capacity, causing the contact to overheat. At this moment, it is necessary to adjust the operating organization so that the moving contact is completely inserted into the static contact ...

The role of Delixi inverter The role of Delixi inverter

1. It can reduce the impact on the power grid, and there will be no problem of excessive peak-to-valley difference. 2. It can speed up the controllable function, and then speed up the slipping according to the needs of the user; 3. The abort mode of the motor and equipment is controllable, ...

Delixi inverter selection principle Delixi inverter selection principle

1. According to the load type, confirm the type of inverter: different load types, speed requirements and power size, the need to choose different types of Delixi inverter. Therefore, it is necessary to understand in detail the type of motor load to be controlled in order to find the most suitable type. ...

Delixi leakage protector tripping causes and solutions Delixi leakage protector tripping causes and solutions

1. The leakage protector does not match the load. This situation mostly occurs when using high-power electrical appliances, and it is generally only necessary to replace the leakage protector that matches the practical needs from scratch. 2. Check whether the switch wiring is correct, ...

The difference between Delixi single-phase and three-phase AC voltage regulators The difference between Delixi single-phase and three-phase AC voltage regulators

Delixi's communication regulator is divided into single-phase communication regulator and three-phase communication regulator. Among them, the types of single-phase communication regulators are mainly TND, TND3, AVR, JJW-D, DBW and other types; The types of three-phase communication regulators are mainly SJW, JJW-S, SBW and so on. ...

Voltage regulator failure and solution - Delixi Voltage regulator failure and solution - Delixi

1. There is no output, no voltage indication or no start when the machine is turned on. Overvoltage or undervoltage maintenance 1. Adjust the internal output voltage adjustable potentiometer 2. The wrong phase and the lack of phase are maintained, and the two phases are arbitrarily replaced by three phases 3. The main control circuit board is broken 3. Replace 4. The output AC has been ...

Delixi leakage circuit breaker identification method Delixi leakage circuit breaker identification method

1. Appearance Genuine Delixi switch shape is more fashionable, looks elegant and beautiful, and the surface is neat, impact resistance is relatively strong, will not briefly crack or yellow. And most imitations will turn yellow after a period of use...

Delixi inverter all aspects of the selection of precautions Delixi inverter all aspects of the selection of precautions

The inverter is a device that can control the speed of the motor, and it completes the speed regulation by adjusting the voltage and frequency of the motor. When selecting an inverter, there are several factors to consider, including the power of the motor, the type of load, the operating environment, etc. This article will specifically introduce the selection of frequency converters ...

Low dropout linear regulator application type - Delixi Low dropout linear regulator application type - Delixi

1.AC/DC the use of power supply Schematic diagram of the use of low-dropout linear regulators in AC/DC power supplies. In this circuit, the AC voltage is stepped down by the power transformer to obtain the low voltage of communication, and then the unstable DC voltage is obtained through the rectifier filter circuit, and then the voltage is regulated linearly by the low dropout ...

Delixi inverter use characteristics and applications Delixi inverter use characteristics and applications

Delixi inverter is a kind of inverter with both high quality and stability, it has excellent function and strong function, widely used in manufacturing, construction industry and energy conservation and environmental protection areas. Let's take a look at some of the characteristics and uses of Delixi inverter. ...

Characteristics and parameters of industrial molded case circuit breaker - Delixi Characteristics and parameters of industrial molded case circuit breaker - Delixi

1. Extra limit short-circuit breaking can be used for Icu There are two types of breaking capacity targets for circuit breakers: additional limit short-circuit breaking capacity of 4U and additional operating short-circuit breaking capacity Ics. As a characteristic parameter, ICS is not only a brief consideration of the breaking ability of the circuit breaker, but also a breaking purpose.

Delixi frequency converter E series precautions Delixi frequency converter E series precautions

1. Before the inverter device is in place and debugged, please tighten the components, especially the connecting bolts of the wire part, if not tightened, the connection will be heated and cause fire. 2. The on-site planning of the installation should be reasonable, and the excellent ventilation environment should be maintained. 3. The incoming and outgoing power lines of the inverter are not ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top