1. What should I do if the indicator light is on and when it is dark
Generally, the reason for this situation is that the line contact is poor or the screws of the terminal are not tightened, we should check the condition of the line, connect the power cord and tighten the screws, and press the wire.
2. What should I do if the indicator light is not on
The reason for this situation is usually that there is a problem with the wiring, or the signal light selected does not meet the requirements of the power supply voltage. At this time, we have to check whether the power switch is turned on, whether the line is unobstructed, and if it is a DC circuit, the resistance step-down indicator should be selected.
3. The indicator light is smoking
This condition is more serious, and generally leads to direct damage to the indicator light, which is generally caused by the additional operating voltage of the power supply voltage higher than the indicator light, or the line may be short-circuited. At this time, we need to check the power supply voltage, and we need to choose an indicator light that matches the voltage.
4. What should I do if the brightness of the indicator light is not good and it is very dark
This situation is generally that the power supply voltage is lower than the additional operating voltage of the indicator light, which is the same as the above, but the indicator light will not be damaged, and the indicator with the same additional operating voltage and power supply voltage can be selected.
|
More on that
|
The difference between an isolation switch and a circuit breaker
The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position.
Isolate ...
|
|
Delixi inverter load type
The correct choice of Delixi inverter is very critical to the normal operation of the control system. When selecting a frequency converter, it is necessary to fully understand the load characteristics driven by the frequency converter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan, water pump ...
|
|
Delixi participated in the 4th China Electrical Appliance Culture Festival
On January 27, the "4th China Electrical Appliance Culture Festival and World Electrical Products Expo" was grandly opened in Liushi, Wenzhou, the capital of China's electrical appliances. More than 500 companies from home and abroad showed their faces on more than 1,400 booths. The largest Delixi exhibition hall with a booth area of more than 1,800 square meters ...
|
|
Delixi circuit breaker mechanism spring design
The spring is a widely used component in the circuit breaker mechanism, and the critical spring has a great impact on the function of the circuit breaker. From the perspective of energy, combined with the installation space of the tension spring, the author uses the existing accounting formula of the tension spring to solve the unknown quantity from the known quantity to obtain the required tension spring parameters.
|
|
Delixi voltage regulator in the case of no load stable work?
Most modern LDOs and switching regulators operate reliably under no-load conditions, and some older power devices require a minimum load to ensure stability, because one of the electrodes that needs to be compensated is affected by the payload resistance. For example, the LM1117 requires a load current of at least 1.7 mA (most ...
|
|
The reason for the heat and heat of the switch socket in Delixi
1. The socket quality is low quality
First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...
|
|
Delixi spare parts replacement cycle
1. Cooling fan (2-3 years)
As long as the inverter is in use, the cooling fan has always been running, so the cooling fan is generally a short-service life accessory, generally after the use of the cooling fan for 2-3 years, the bearings, balls, motors, etc. of the fan are seriously worn, and they need to be replaced.
|
|
Delixi rangefinder analysis
Delixi Group focuses on low-voltage power distribution and industrial automation in the field of comprehensive solutions suppliers, founded in 1984, is a collection of industrial operations, brand operations, capital operations as one of the large enterprise groups, for 18 consecutive years ranked among the top 500 Chinese enterprises. Delixi rangefinder is designed for ...
|
|
Type of use of AC regulated power supply
(1) Ferromagnetic resonant communication regulator: a communication regulator composed of a full choke and a corresponding capacitor, with constant voltage voltammetry characteristics. The full type is a typical structure in the early stage of this type of regulator. It has simple structure, convenient production, wide allowable scale of input voltage, reliable operation, and overload energy.
|
|
Delixi uses three-phase regulators need precautions
1. If the fuse is burned out, please approve the load equipment as soon as possible, make repairs in time, and restore power;
2. If you use a fixed amount of fuse, please use a regular line, and do not match it at will, so as not to cause ...
|
|
The difference between linear regulator and switching regulator - Delixi
The switching voltage regulator is a different kind of regulated power supply from the linear voltage regulator, and its circuit types mainly include single-ended flyback, single-ended forward, half-bridge, push-pull and full-bridge.
The difference between it and the linear power supply is that the transformer in the circuit does not work at the power frequency, but at the power frequency.
|
|
The treatment method of leakage protector often tripping - Delixi
1. Trial delivery and commissioning method
The first thing to find is the fault of the remaining current action maintainer itself. The detailed operation method is: first block the power supply, and then remove all the zero-sequence transformer load side leads of the remaining current action maintainer (the second and third level remaining current action maintainers will directly remove the outgoing ...
|
|
Delixi parameter voltage regulator performance and advantages
1. Its overall inductive skills function is the best, its design does not use electronic equipment, and the environmental adaptability and stability and reliability function are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...
|
|
Low dropout linear regulator design power supply precautions - Delixi
1. Pay attention to the maximum value of output current: this is a very critical parameter, the current used exceeds the maximum output current of LDO, then the voltage is unstable, and the system will fail.
LDO limit parameters: The output current is considered according to the 2/3 criterion. The cost of the whole system ...
|
|
Damage and repair of internal electronic components of the inverter - Delixi
1. Repair the damage of the inverter rectifier block
The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter).
Middle...
|
|
Delixi inverter in the single girder crane electric hoist application case
Single-beam crane throughout the use of electric hoist as a lifting mechanism, with a simple structure, convenient use, widely used in some lifting tonnage small industrial and mining enterprises, domestic hoist crane throughout the use of conical rotor motor, cone motor structure than the general motor messy, ordinary method speed regulation is more difficult ...
|
|
Delixi linear and switching regulators introduced
01. What is a linear voltage regulator?
A linear regulator uses a transistor or FET operating in its linear region to subtract the excess voltage from the input voltage of the application to produce a conditioned output voltage.
The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...
|
|
Delixi's AC contactor selection
It is selected according to the type of load current in the circuit. AC loads should be selected AC contactors, DC loads should be DC contactors, assuming that the control system is mainly AC loads, DC motors or DC loads have a small capacity, AC contactors can also be used to control, but the contact of the ...
|
|
Delixi voltage regulator power selection
1. The output power of Delixi voltage regulator is the maximum power
Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also rational loads that start instantaneous currents.
|
|
Delixi Electric universal switching power supply
Delixi general switching power supply can provide stable DC output products, widely used in communications, LED displays, industrial control, radio and television, computer networks, medical equipment, intelligent monitoring and other fields.
Delixi universal switching power supply SA, DA, TA, QA Type 85 - 132 / ...
|
|