After adding the I/O module, you need to set it in the CX-PROGRAMMER program.
Find the IO table and unit settings, double-click to find the mainframe [0000], dot + sign, then double-click 00 (if not set), 00 represents the module number closest to the CPU, find the basic I/O in the pop-up window (if it is not an I/O unit, select the corresponding category), dot + and then find the input and output module model you added, and select it. If there are more than one, add them as described above.
There is a simpler way, that is, after connecting with the PLC online, double-click the IO table and unit settings, find Options in the menu bar of the small window, and then select Transfer from PLC. As for programming, you can use it directly, and the IO addresses are arranged in order.
|
More on that
|
Omron Switches – What Aspects Are Needed for Switching Power Supply Design?
1. Wiring
The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...
|
|
How to connect Omron plc IP address?
1. The IP address of the computer is automatically obtained.
2. The computer is directly connected to the PLC network port.
3. Open the DirectEthernetUtility software. Software Setup Start - > All Programs - > OMRON - >Communications Middleware Utilities - > DirectE...
|
|
Wiring method of Omron PLC
The connection method is as follows: the brown wire is connected to the PLC input point, the PLC com point is connected to the positive pole of the power supply, and the negative pole of the power supply is connected to the blue wire.
NPN type: brown is connected to the positive power supply, blue is connected to the negative power supply, the black wire is connected to the PLC input point, and the PLC com point is connected to the positive power supply. NPN is a leak type, and the detected object ...
|
|
Omron PLC serial port communication protocol
There are two simpler ways to communicate:
1. Through serial port communication, CP1W-CIF01, that is, RS232 serial port option board is installed on the two CPUs respectively, and simple communication is achieved through PCLink protocol without programming;
2. Through network port communication, CP1H installs CP1W-CIF41 network port option board ...
|
|
Introduction to the classification of Omron relay switch contacts
1.A contacts
A contact is a contact in which the two contact terminals are separated (OFF) when the switch is not operated, and closed (ON) when the switch is operated. If you want to start the load by operating the switch, you can use the A contact. A circuit is a circuit that uses a contact without operating the switch (pressing ...
|
|
How are Omron switch relays wired?
One. Before connecting, determine the voltage required for the proximity switch, and in the case of a 3-wire system, determine whether it is PP type or P type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems.
Two. Wire proximity switches are connected in series when connected to relays. i.e. the relay is connected to the proximity switch to give it ...
|
|
Analysis of common failures of Omron PLC
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|
|
How to choose Omron micro switches?
1. Understand how the shape and scale of the switch affect other characteristics
The scale is important when choosing a micro switch. The switching scale is directly related to its characteristics, including current scale, stroke, and operating force. For example, the smallest microswitch on the market today measures 0.50" x 0. ...
|
|
Omron PLC troubleshooting
1. Power check:
The first thing to analyze is the reliability of the power supply and ground of the Omron PLC. Visually inspect power and ground cables for damaged, corroded, or other suspicious links.
Power supplies can also be electrically tested. If there is AC power in the PLC processor, test ...
|
|
Omron PLC formatting method
1. Click [Controller] - [Mode] - [Programming Mode].
2. Click [Yes] in the pop-up window, and at this time, the PLC is in programming mode.
3. Click [Controller] - [Clear All Memory].
4. Click [OK], and the PLC memory is successfully ...
|
|
Maintenance method of Omron PLC
1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found;
(2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...
|
|
Omron PLC's maintenance process and technical requirements
(1) When measuring voltage, it is necessary to use a digital voltmeter or a universal meter with an accuracy of 1%.
(2) The power supply rack and CPU motherboard can only be removed when the main power supply is cut off;
(3) Before the RAM module is removed from the CPU or plugged into the CPU, the power supply of the PC should be disconnected.
|
|
Omron Relays – What are the main functions of relays?
(1) Expand the control range: for example, when the control signal of the multi-contact relay reaches a certain value, it can be changed, interrupted and connected to multiple circuits at the same time according to the different forms of the contact group.
(2) Amplification: For example, sensitive relays, intermediate relays, etc., with a very small ...
|
|
Parameter settings for Omron inverters
1. First of all, set the parameters of Omron inverter according to the rated voltage, rated frequency, rated power and other parameters of the motor;
2. Secondly, according to the actual operation of the motor, adjust the parameters of the Omron inverter to achieve the best operation effect;
3. Finally, ...
|
|
Routine maintenance methods of Omron relays
1. In the operation of Omron relay, if there is an abnormal sound or other abnormal conditions, the operation should be terminated first, and the skilled and professional repair staff should be notified to repair, and the operation can be resumed after the common fault is cleared.
2. In the whole process of maintenance, check the spring ...
|
|
What is the main role of Omron micro switches in household appliances?
There are 3 types of micro switches, which perfectly match the precise control needs of household appliances
Micro switch refers to a contact mechanism with a small contact spacing and a snap-action mechanism, a contact mechanism that carries out the switch action with a specified stroke and a specified force, covered with a shell, and a drive rod on its outside, ...
|
|
Omron | A high level of safety for people, equipment and products
problem
At manufacturing sites where social distancing is required, we can increase productivity by reducing the number of workers
Due to the pandemic, social distancing was also required on manufacturing sites, and manufacturing with fewer workers had to be achieved quickly. Prior to this, the automatic ...
|
|
Omron applications in semiconductor wire bonding equipment
Process introduction
High-purity gold wire (Au), copper wire (Cu) or aluminum wire (Al) is used to connect the Pad and Lead by soldering.
■ PAD is the external contact point of the circuit on the chip
■ Lead is the connection point on the Lead Frame.
W/B is the encapsulation process ...
|
|
What are the functions of Omron relays?
1. Expand the scope of control. For example, when the control signal of a multi-contact relay reaches a certain value, it can be changed, interrupted, and connected to multiple circuits at the same time according to the different forms of contact groups.
2. Zoom in. For example, sensitive relays, intermediate relays, etc., with a very small control ...
|
|
There are four main characteristics of Omron PLC
1. High reliability
The PLC replaces a large number of intermediate relays and time relays in the relay control system with software, and the wiring can be reduced to less than one-tenth of the relay control system, which greatly reduces the possibility of poor contact contact. In addition, the PLC itself has a strong self-diagnosis ...
|
|