Omron Switches – What Aspects Are Needed for Switching Power Supply Design?

Create Date: 2024-8-30 12:03:23|Source: Omron/Omron

1. Wiring

The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. Therefore, I suggest that you pay attention to the actual situation of the wiring when buying a switching power supply to prevent irreparable damage.

2. Meta layout

Element design is also very important, in the design must follow the physical design principles, do not rely on your own ideas to change the position of the element, in case of short circuit accidents. In addition, designers should also check the quality of the product themselves when purchasing the element.

3. Parameters

In the design of switching power supply, we must understand every structural detail in it, especially remember the parameters, so as to give specific instructions for future use. The detailed parameters are also convenient for the later testing of the switching power supply, which will also save some time.

4. Inspection

After the design of each switching power supply, it must be strictly inspected before it can be produced, and only through the inspection can the availability and applicability of the switching power supply be determined, so as to price the switching power supply. When inspecting, first of all, start from the circuit, detect the real working environment of the switching power supply, what kind of environment is the most suitable to work and operate, to avoid circuit accidents in some environments, safety is the first thing we should care about, so we need to carefully check the switching power supply.

5. Choose the right power

In order to make the life of the switching power supply longer, I recommend that you choose a model with a rated output power of 30%. If the system requires a 100W power supply, it is recommended to choose a model with an output power rating greater than 140W, and so on to effectively improve the life of the power supply.
Omron Switches – What Aspects Are Needed for Switching Power Supply Design?

More on that
Omron Heater Status Monitor K7TM was officially released Omron Heater Status Monitor K7TM was officially released

In June 2022, Omron Automation (China) Co., Ltd.'s new product [Heater Status Monitor K7TM] was officially released. Without going to the site, through real-time monitoring of heater status, the aging trend of heater equipment that cannot be captured manually is clearly displayed, and predictive maintenance is realized!   In high temperatures ...

How to detect the type of Omron relay How to detect the type of Omron relay

1. Measuring contact resistor Use the resistor file of the universal meter to measure the normally closed contact and the moving point resistor, and its resistance should be 0; The resistance of the normally open contact and the moving point is infinite. This makes it possible to distinguish which is a normally closed contact and which is normally open. 2. Test the coil resistance ...

Introduction to Omron electronic thermometer and how to use it Introduction to Omron electronic thermometer and how to use it

Using an Omron electronic thermometer, which is displayed digitally and compared with a conventional thermometer, there is a small chance of error, generally no more than 0.1 degrees, so there is little need to worry about inaccuracies. Every time you use it, it's also very simple, just press the power switch ...

Omron inverter maintenance failure alarm code detailed description Omron inverter maintenance failure alarm code detailed description

Omron inverter maintenance fault alarm is mainly divided into abnormal alarm and warning alarm, here we only explain the code displayed Warning display Over Torque Detection (OL2) FUNCTION code error (CE01) Registers NO. Error (CE02) Data...

【Omron Industry Case】Application case of robot in cell stack welding 【Omron Industry Case】Application case of robot in cell stack welding

Equipment Overview The stack welding machine is mainly used for the overlap welding of monocrystalline and polycrystalline cells in fully automatic crystalline silicon solar cell modules, and is suitable for series welding of small-size crystalline silicon solar cells.

Omron alarm code analysis Omron alarm code analysis

Warning display Over Torque Detection (OL2) FUNCTION code error (CE01) Registers NO. Error (CE02) Data Error (CE03) Slave Execution Error (CE04) Slave Execution (CE06) Communication Timeout (CE10) Display...

The working principle and purpose of Omron relays The working principle and purpose of Omron relays

How it works Add a certain voltage at both ends of the coil, a certain current will flow through the coil, thus producing an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction and attract to the core, thereby driving the dynamic contact and static contact (normally open contact) of the armature ...

How to modify the program online of Omron PLC? How to modify the program online of Omron PLC?

1. After determining the object in Omron PLC, click Write Mode in the edit window. 2. Next, directly select the relevant software components and double-click. 3. At this time, you need to change the number through the ladder diagram input and select OK. 4. Such a ...

Maintenance method of Omron PLC Maintenance method of Omron PLC

1. Maintenance procedures, regular testing and adjustment of equipment (1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found; (2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...

Possible malfunction of Omron switch contacts Possible malfunction of Omron switch contacts

1. The internal components of Omron switch are not in good contact. 2. Omron switch malfunction. 3. The Omron switch is fused. 4. The insulation performance of Omron switch becomes weaker. ...

What are the common faults of Omron PLC? What are the common faults of Omron PLC?

1. CPU abnormality: When the CPU abnormality alarms, check the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly. 2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...

The interrupt function of Omron CP1 series PLC and the establishment of interrupt program The interrupt function of Omron CP1 series PLC and the establishment of interrupt program

Since the main program of the PLC is the working mode of cyclic scanning, some more urgent special tasks (interrupt subroutines) that occur randomly must be executed immediately without being affected by the scanning cycle, and the CPU temporarily aborts the main program and executes the interrupt subroutine, so the working mode is the interrupt function ...

Omron brought diversified solutions to the digital tour (Jinan Station)! Omron brought diversified solutions to the digital tour (Jinan Station)!

Recently, the 6th National Digital Upgrade Tour Seminar was held in Jinan. Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") attended the event as a leading automation company, and focused on the pain points in the digital transformation of local enterprises with more than 100 enterprise representatives from various industries.

Troubleshooting of Omron PLC Troubleshooting of Omron PLC

1. Check the switches in the battery or sensor area as well as in the problem area. Such as tool changers, tool changers and pallet changers. Look for potential alternatives or tools that may be defective through electronic prints. 2. Test the Omron PLC or internal control diagnosis of each output LED. Manual...

Key Features of Omron PLC: Key Features of Omron PLC:

(1) Flexible structure Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility. (2) High transmission quality, fast speed and stable bandwidth Can be very ...

Routine maintenance of Omron PLC Routine maintenance of Omron PLC

1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented. 2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.

What's the deal with Omron PLC without output voltage? What's the deal with Omron PLC without output voltage?

1. The indicator light at the output of the PLC is on, indicating that the DO point of the PLC has been closed; 、 2. The DO point of PLC is equivalent to a dry contact switch, imagine that an on/off switch on a line is closed, if you measure the voltage on both sides of this switch, there will be no voltage, thinking that the switch itself ...

Omron set off a digital low-carbon boom at the expo Omron set off a digital low-carbon boom at the expo

From November 5th to 10th, the 5th China International Import Expo was held in Shanghai, where multinational companies from all over the world gathered to participate in the annual international economic and trade event. As a global expert in digital transformation in the field of automation, Omron has entered the ...

How can Omron micro switches meet the market demand for smart locks? How can Omron micro switches meet the market demand for smart locks?

Nowadays, the smart lock market has a wide variety of names, and it can't help but give people a sense of "random flowers gradually charming eyes". So, how to choose a cost-effective smart lock? In fact, in smart locks, micro switches can be said to occupy an important position. Microswitches ...

There are four main characteristics of Omron PLC There are four main characteristics of Omron PLC

1. High reliability The PLC replaces a large number of intermediate relays and time relays in the relay control system with software, and the wiring can be reduced to less than one-tenth of the relay control system, which greatly reduces the possibility of poor contact contact. In addition, the PLC itself has a strong self-diagnosis ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top