1. In the operation of Omron relay, if there is an abnormal sound or other abnormal conditions, the operation should be terminated first, and the skilled and professional repair staff should be notified to repair, and the operation can be resumed after the common fault is cleared.
2. In the whole process of maintenance, check whether the spring has abnormal conditions such as deformation, aging, cracking, etc., and take effective countermeasures if found.
3. If you want to replace the Omron relay, you should pay special attention to whether the performance parameters of the replaced Omron relay are consistent with the natural environment and use standards of the on-site use, so as to ensure that the Omron relay used in the installation can be used for a long time. View. Whether the pins of the Omron relay are bent, discolored, or otherwise mechanically damaged.
4. Check the Omron relay housing for scratches, cracks, damage and other mechanical damage.
5. Check whether the tightening screws and bolts of the Omron relay are loose, rusty and other abnormal conditions, and if there is any abnormal situation, please deal with it immediately.
6. Check whether the Omron relay positioning pin is damaged or falling, check whether the positioning pin and the base are the same, whether the two cooperate with each other loosely, and whether they are inseparable from each other.
7. Keep the surrounding environment of Omron relay clean, remove dust, water, moisture and other factors that are not conducive to the normal operation of the relay, so as to make Omron relay more safe and reliable operation.
|
More on that
|
How to classify Omron signal relays?
1. Classified according to the principle of action
The electromagnetic relay drives the armature and the movable part to act through the suction generated by the current in the relay coil in the electromagnet and changes the working state of the contact system. Such as DC stepless relays, DC polarized relays, AC relays, binary differential relays...
|
|
Common problems and solutions in the maintenance process of Omron PLC
1. CPU abnormality:
When the CPU is abnormally alarmed, check all the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may have problems in turn, find out the problem units, and deal with them accordingly
2. Memory abnormality:
Memory anomaly ...
|
|
Analysis of common faults and causes of Omron relays
First, the condition that the relay is not turned on
1. If the load current exceeds the rated conversion current of the relay, the relay will have a short circuit fault, and the relay with a large rated voltage should be replaced
2. At the working temperature where the relay is located, the amount of current borne by the relay is ...
|
|
How to modify the program online of Omron PLC?
1. After determining the object in Omron PLC, click Write Mode in the edit window.
2. Next, directly select the relevant software components and double-click.
3. At this time, you need to change the number through the ladder diagram input and select OK.
4. Such a ...
|
|
Omron's non-contact temperature sensors bring convenience to work and life
In recent years, Omron has launched MEMS non-contact temperature sensors, and the technology incorporated into them has gradually presented the future of smart life in front of our eyes. Next, let's learn more about Omron's MEMS contactless sensor, and deeply feel the future of work and life.
|
|
Application of Omron automatic gluing robot
Process introduction
Since the implementation of the [plastic restriction order] in 2007, plastic packaging has been greatly restricted. Subsequently, all kinds of metal cans represented by beer cans, tea cans, and oil cans are increasing, and metal packaging has begun to usher in a period of rapid development.
Metal cans are divided into ...
|
|
Omron attended the 2022 P&G Electrical Automation Symposium
Recently, the 2022 P&G Electrical Automation Seminar held by Procter & Gamble (China) Co., Ltd. (hereinafter referred to as "P&G") was held in Guangzhou. Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") was invited to attend the meeting and worked with the engineering, manufacturing, R&D and other departments of P&G factories on behalf of the ...
|
|
How to connect Omron plc IP address?
1. The IP address of the computer is automatically obtained.
2. The computer is directly connected to the PLC network port.
3. Open the DirectEthernetUtility software. Software Setup Start - > All Programs - > OMRON - >Communications Middleware Utilities - > DirectE...
|
|
Omron set off a digital low-carbon boom at the expo
From November 5th to 10th, the 5th China International Import Expo was held in Shanghai, where multinational companies from all over the world gathered to participate in the annual international economic and trade event.
As a global expert in digital transformation in the field of automation, Omron has entered the ...
|
|
【Omron industry case】The application of robots in the assembly line of automobile high-pressure oil pump
Equipment Overview
The high-pressure oil pump (abbreviation: HDP) is the main power source to drive the fuel pressure of the automobile engine.
The "high-pressure oil pump robot automatic assembly line" mainly realizes the intelligent supply of each component on the high-pressure oil pump and the automatic assembly of each component by the robot.
Work...
|
|
Omron PLC--CPM1A-V1 series product model
1. CPM1A-10CDR-A-V1 10-point CPU unit AC100-220V, 6 points in, 4 points relay output
(1A is the model code; 10 means that the total number of input and output points is 10 points, specifically 6 points of input and 4 points of output; C means CPU unit; D stands for mixed type, that is, there is a loss ...
|
|
Omron brought a variety of new blood pressure monitors to the Expo
Hypertension is the main risk factor for cardiovascular and cerebrovascular diseases, and is known as the "invisible killer of human health". The Lancet study shows that the number of hypertensive adults aged 30-79 has increased from 650 million to 1.28 billion in the past 30 years. In China, hypertension is also a cardiovascular disease.
|
|
Omron's digital × low-carbon solutions were unveiled in the industrial automation exhibition area
The 5th China International Import Expo opened in Shanghai. Based on the ever-evolving manufacturing concept "i-Automation!" The digital and low-carbon solutions created were presented to the audience on the heavyweight platform of the Expo.
At present, the curtain of global carbon neutrality has opened, and the ...
|
|
How does Omron PLC keep the relay directive used?
1. In the Omron PLC programming software, select the program segment to use the hold relay command.
2. Insert the holding relay command in the program section and assign the appropriate opcode to it.
3. Modify the status of the hold relay command, for example, the hold relay needs to be kept ...
|
|
What are the main items of Omron PLC overhaul?
1. Overhaul the power supply. It is possible to detect whether the voltage variation range is within the permissible ± 10% at the power terminal.
2. Working environment. Focus on checking whether the temperature, humidity, vibration, dust, interference, etc. meet the standard working environment.
3. Power supply for input and output. Available in the corresponding ...
|
|
Features of Omron 3G3JZ series inverter
1. Standard configuration with RS485 interface, Modbus bus communication function;
2. At 3Hz, it can provide more than 150% torque output and start quickly;
3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive;
4. Equipped with simple energy-saving function;
5. Controlled ...
|
|
What are the selection factors of Omron relays - intermediate relays?
1. Factors of geographical location and climate
It mainly refers to factors such as altitude, ambient temperature, humidity, and electromagnetic interference. Considering the universal applicability of the control system, it must be taken into account for many years
Due to the particularity of reliable operation for many years, the key parts of the device must be selected with high insulation, strong resistance...
|
|
Introduction to the classification of Omron relay switch contacts
1.A contacts
A contact is a contact in which the two contact terminals are separated (OFF) when the switch is not operated, and closed (ON) when the switch is operated. If you want to start the load by operating the switch, you can use the A contact. A circuit is a circuit that uses a contact without operating the switch (pressing ...
|
|
Introduction to the functions of Omron's dual-channel intelligent fiber amplifier E3X-MZV
Dual-channel intelligent fiber amplifier
E3X-MZV
Optical fiber sensors are widely used to detect the presence and absence of vibration plates, rechargeable battery pole piece winders, digital product assembly and other equipment.
Omron's new fiber optic amplifier selects the functions and performance required for detection and performance.
|
|
Fault repair of Omron blood pressure monitor
1. Mercury leakage
1. The cause of mercury leakage failure
Under normal circumstances, the sphygmomanometer will often leak mercury, which may eventually cause a certain error in the measurement value of the sphygmomanometer device. Then the cause of this malfunction is generally manifested as the blood ...
|
|