1. In addition to the short-circuit protection function of the fuse, the air switch can also realize the overload protection of the circuit.
2. The fuse is a one-time protection device, which must be replaced once it is blown and is very troublesome, so its reusability rate cannot be compared with the air switch.
3. The air switch has an arc extinguishing design, which is not easy to form a short circuit of the power supply due to the generation of arc when cutting off a large load, and the fuse determines that its arc extinguishing capacity has a large gap with the air switch due to its installation method, which is easy to lead to short circuit accidents.
4. The action sensitivity of the fuse is worse than that of air.
5. The indication after the fuse is blown is not as clear as the air switch.
6. When the air switch is current, it can jump off, but if it dies, it can only burn out, so it is good to use the air switch. If your family's rice protection and so on add up to a total of 8A power, then you can choose a 10A air switch.
|
More on that
|
Tianyi switch - the selection of disconnector switches
Rated voltage:
The rated voltage of the disconnector (KV) = the nominal voltage of the circuit * 1.2/1.1 times.
Rated current:
The standard value of rated current should be greater than 150% of the maximum load current.
Rated Thermal Stability Current:
Select a rated ...
|
|
Tianyi switch - what does the 2P3P of the air switch mean
2P means two poles, which means that this air switch has two connection ports, one to connect to the neutral wire and one to the live wire, which is suitable for single-phase circuit connection, or can also be used to connect two-phase power supply in a three-phase circuit.
3P is the meaning of three poles, there are three connection ports, and all of them are ...
|
|
Tianyi switch - the use of dual power transfer switch
1. Install the dual power transfer switch with the power supply to ensure the correct access of the power supply.
2. Adjust the handle of the dual power transfer switch to the "automatic" position, so that the power supply will automatically detect the state of the other power supply, when one of the power supplies fails, the other power supply will ...
|
|
Tianyi switch - the environmental conditions of the high-voltage load switch
1. Altitude: 2000m and below;
2. Ambient temperature: -25°C-+40°C;
3. Relative humidity: the daily average value is not more than 95%, and the monthly average value is not more than 90%;
4. Places without conductive dust, corrosive gases and water vapors;
5. No fire ...
|
|
Tianyi switch - the principle and main purpose of transfer switch
1. Principle
The contact system of the transfer switch consists of several moving contacts embedded in the insulated housing with a static contact base and a movable support. The moving contact is a double-break butt contact bridge, which turns the circuit on or off with the rotating shaft of the rotating shaft attached to different positions. Positioning...
|
|
Tianyi button signal light - how to choose and use the button indicator light
How to use the indicator color correctly?
1. The indicator light (also known as the signal light) is mainly used to attract the attention of the operator or instruct the operator to carry out a certain operation in the way of bright indication, and as an indication that a certain state or instruction is being executed or has been executed.
2. General ...
|
|
Tianyi switch - routine detection of air switch
The socket, lamp head, kitchen, bathroom, refrigerator, air conditioner of each route should be put out separately, and each route should have a separate air switch, high-power rooms, such as kitchens and bathrooms, the line of more than 4 square millimeters should reach 20A, and the general lamp head line should only be 16A, and each line ...
|
|
Tianyi switch - dual power supply automatic transfer switch normal working conditions
1) Ambient air temperature: The upper limit of ambient air temperature is +40°C, the lower limit of ambient air temperature is -5°C, and the average value of ambient air temperature for 24h does not exceed +35°C
2) Altitude: The altitude of the installation site does not exceed 2000m.
3) Atmospheric conditions: Atmospheric relative humidity in the surrounding air ...
|
|
What are the common problems of Tianyi switch - disconnector?
1. What are the common faults?
Answer: The common faults of the disconnector are: (1) The contact part is overheated. (2) Porcelain insulation damage and flashover discharge. (3) Refuse to pull and close. (4) Wrong pulling and closing.
2. The overheating of the contact part of the disconnector during operation is caused by ...
|
|
Where can Tianyi switch - limit switch be used?
daily life
There are many aspects of the use of limit switches, and it is found in many electrical appliances. So what effect can such a simple switch have? It is first and foremost a chain maintenance effect. The most common example is its use in washing machines and tape recorders (video recorders). ...
|
|
Tianyi button indicator - button indicator induction circuit fault and solution
First, the reason for the fault of the induction circuit of the switch button indicator
1. Aging of circuit board: The circuit board of the switch button indicator induction circuit board may be aged if it has been used for too long, resulting in leakage in the circuit, and then the induction failure of the indicator light.
2. Sense ...
|
|
Tianyi switch - the characteristics of low-voltage isolation switch
1. When overhauling electrical equipment, provide an electrical interval and a visible disconnection point to ensure the personal safety of maintenance personnel.
2. The disconnector can not be operated with load: it cannot be operated with rated load or large load, and it cannot be divided or combined with load current and short circuit current.
|
|
Tianyi switch - precautions for the use of proximity switches
1. If it is installed on metal, a certain space must be ensured to avoid interference between the proximity switch and the metal other than the detection object, resulting in failure. The metal parallel to the sensing surface must be 3 times the sensing distance from the sensing surface. The metal around the shaft of the proximity switch must be outside the cylinder, close to ...
|
|
Tianyi switch - the role of the travel switch (limit switch) and its working principle
The scope of use of the travel switch (limit switch).
The range of use of travel switches (limit switches) is very wide, so what is the effect of travel switches (limit switches)? The position switch (limit switch) refers to the maintenance of the micro switch from external forces, oil, water, gas, ...
|
|
Tianyi switch - the difference between C type and D type of air switch
The meaning is different, the scope of application is different, and the role is different.
Air opening C represents the current, and the D model represents the power. The scope of use is different. If it is a household electricity, the air switch of the C model is generally chosen. The role is different. Type C it is used for home lighting use, Type D is suitable for ...
|
|
What are the specifications and models of Tianyi switch - air switch?
1. Common air switch models in the family
Common family models: DZ series, C16, C32. C40, C80, C100, C120 and other products, of which C represents the starting current, such as: C32 means that the starting current is 32A, which can drive a 6500 watt water heater, C40 ...
|
|
Tianyi Switch - Cam Switch and Load Disconnector Q&A (1-10)
Q1: What is the difference between P switch and T switch?
A: P switch is a load isolation switch, mainly used for the opening and isolation of the main circuit load, only 3P and 3+N, can add auxiliary contacts; The T-switch is a multi-function switch with a wide variety of contact sequences, modular contact units, which can ...
|
|
Q&A on Cam Switches and Load Disconnectors (11-21)
Q11: What is the maximum number of connecting rods for the rear mounting of P1 and P3?
A: Up to 4 sections can be added, each section is 25mm.
Q12: Does the P switch with SVB in the model come with PE grounding and N-wire terminals?
A: P switch models with SVB are equipped with PE grounding and ...
|
|
Tianyi switch - the structural characteristics of high-voltage load switch
The load switch and combination electrical appliances are mainly composed of frames, isolation switches (the current limiting fuse of the combination is on the isolation switch), vacuum switch tubes, grounding switches, spring operating mechanisms, etc.
The product has compact structure, small size, long life, strong closing and breaking ability, and simple operation and maintenance.
|
|
Tianyi switch - the switching mode of dual power transfer switch
Conversion conditions: The purpose of requiring dual power supplies is to complete the automatic and reliable conversion of dual power supplies under "specific" circumstances. This "specific condition" is the conversion premise of the dual power supply, or the conversion condition, which is the primary consideration for choosing the dual power supply.
A. In the event of a power failure ...
|
|