Mitsubishi PLC network structure

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. CC-Link fieldbus connection is selected, the number of wiring is greatly reduced, and the maintainability of the system is improved. In addition, not only ON/OFF and other switching data, but also can be connected to ID system, barcode reader, inverter, human-machine interface and other intelligent equipment, from the completion of various data communication, to the terminal production information can be completed, plus the collection of machine action status, so that the efficiency of maintenance is also greatly improved. When used in Q series PLCs, CC-Link is more functional and easier to use.

                              Mitsubishi PLC network structure

2. The control layer/MELSECNET/10 (H) is the middle layer of the entire network system, which is a control network for convenient and high-speed processing data transfer between PLC, CNC and other control equipment. MELSECNET/10, as a MELSEC control network, has won high market reviews for its good real-time, simple network settings, program-free network data sharing concept, and redundant loops, and the number of devices selected has reached the highest level in Japan and is rare in the world. MELSECNET/H not only inherits the excellent features of MELSECNET/10, but also makes the network more real-time and has a larger data capacity, which is further accustomed to the needs of shopping malls.

3. The information layer/Ethernet (Ethernet) information layer is the middle and highest level of the network system, which is mainly used to transmit production management information, quality management information and equipment operation data between PLC, equipment controller and production management PC, and the information layer uses the most common Ethernet. It can not only connect to Windows PC, UNIX system operation station, etc., but also to various FA equipment. The Ethernet module of the Q series PLC series has the function of sending and receiving e-mails on the Internet, which allows users to easily send and receive production information e-mails anywhere in the world, and build a long-distance supervision and management system. Together, the FTP server function of the Internet and the MELSEC protocol can easily complete the upload/download of programs and the transfer of information.

In addition, in addition to the above-mentioned networks, Q series PLC can also support the networks of other manufacturers such as Profibus, Modbus, Devicenet, ASi, etc., and can also carry out serial communication such as RS-232/RS-422/RS-485, and carry out data transmission and other communication methods through data dedicated lines and telephone lines.

When communicating in Mitsubishi's PLC network, there is no difference or discontinuity in the type of network, and it is possible to carry out long-distance monitoring, correction, and debugging of data communication and programs across networks, regardless of the level and type of network. MELSECNET/H and CC-Link use a cyclic communication method to send and receive messages automatically and periodically, without the need for a special data communication program, only a simple parameter setting. MELSECNET/H and CC-Link use the broadcast method to send and receive circular communication, so that the data on the network can be shared together. For Ethernet, MELSECNET/H, CC-Link networks used in Q Series PLCs, it is easy to set network parameters and various functions on the GXDeveloper software screen.

More on that
Mitsubishi causes electromagnetic interference Mitsubishi causes electromagnetic interference

1. Harmonic disturbance The rectifier circuit will generate a harmonic current, which will cause a voltage drop on the impedance of the power supply system, resulting in a distortion of the voltage wavepattern, and this distorted voltage will cause disturbance to many electronic devices (because most electronic devices can only operate in the sine wave).

The essential difference between single-chip microcomputer and PLC - Mitsubishi PLC The essential difference between single-chip microcomputer and PLC - Mitsubishi PLC

The difference between PLC and single-chip microcomputer: 1. PLC is a relatively sophisticated control system composed of single-chip microcomputer, and it is a product of the sophisticated and stable single-chip microcomputer application system that has been debugged. There is strong versatility. 2. The single-chip microcomputer can constitute a variety of application systems, and the scale of application ...

Mitsubishi tells you what IGBT is Mitsubishi tells you what IGBT is

Mitsubishi Electric IGBT is the English word Insulated Gate Bipolar Transistor, which means insulated gate bipolar transistor in Chinese. Functionally, IGBT is a circuit switch, and the advantage is that it uses electricity.

The weight conversion method of the Mitsubishi weigh module The weight conversion method of the Mitsubishi weigh module

Component conversion is a process in which an analog signal (load converter output voltage) input from outside the programmable controller is converted into a digital output value and a total component output value, and then stored in buffer memory. After the conversion process, the conversion completion (XE) will change to ON, and the transformation completion mark (Un\G1 ...

Internal data structure of the Mitsubishi PLC FX series Internal data structure of the Mitsubishi PLC FX series

A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following ways in terms of structure or number system. (1) Decimal number Decimal numbers are also known as word data in PLC. It is first and foremost ...

Mitsubishi PLC adjusts the built-in time Mitsubishi PLC adjusts the built-in time

1. TWR (Time Write) command Write the time preset value to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps. The work of the directive ...

One-button adjustment function for Mitsubishi servo motors One-button adjustment function for Mitsubishi servo motors

After the first installation of different servo motors on the machine, they may be poorly matched to the machine during operation, resulting in vibration, noise and other phenomena. The cause of the problem is a mismatch between parameters such as the rigidity of the servo motor and the load-inertia ratio and the machinery. Due to the large number of parameters that affect ...

Find PLC fault method – Mitsubishi PLC Find PLC fault method – Mitsubishi PLC

PLC is an industrial small computer, it has a problem, the first thing to clean up is the PLC ontology problem is still a peripheral problem, if there is a problem with the PLC ontology, often the ERR light is on, maybe the red light is flashing, the normal situation is generally RUN running green light, if it is the ontology to produce this kind of problem, ...

Mitsubishi inverter control mode Mitsubishi inverter control mode

According to the classification of the main circuit operation mode, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter; According to the classification of operating principles, it can be divided into V/f control frequency conversion ...

Software or hardware reasons for Mitsubishi PLC crash Software or hardware reasons for Mitsubishi PLC crash

1. Hardware (1) I/O channeling, the PLC automatically detects the I/O fault and enters the STOP mode. (2) The I/O is damaged, and the program runs to the response signal that needs the I/O, and cannot execute the instruction downward. (3) Expansion module (functional, such as A/D) ...

Mitsubishi inverter overload fault judgment method Mitsubishi inverter overload fault judgment method

1. Check whether the three-phase electricity of the motor is balanced (1) If the three-phase voltage of the motor is unbalanced, then check whether the three-phase voltage at the output end of the Mitsubishi inverter is balanced. (2) If the three-phase voltage of the Mitsubishi inverter is also unbalanced, the problem is inside the Mitsubishi inverter, and it should be investigated.

Mitsubishi PLC FX series programmers and other peripherals Mitsubishi PLC FX series programmers and other peripherals

1. FX series programmer The programmer is an important peripheral device of the PLC, which is used to write the user program to the PLC user program memory. On the one hand, it can be programmed by the PLC, and on the other hand, it can monitor the working status of the PLC. With the development of PLC skills, the multi-...

MITSUBISHI COLLABORATIVE ROBOT MELFA ASSISTA MITSUBISHI COLLABORATIVE ROBOT MELFA ASSISTA

With the popularization of industrial robots in the production site, more and more Mitsubishi collaborative robots, Mitsubishi robots, MELFA ASSISTA, RV-5AS-D on-site issues need to be solved urgently, such as the need for more robot programming engineers, adding labor costs; The teaching is cluttered, and a large number of non-...

Debugging method of servo motor - Mitsubishi Debugging method of servo motor - Mitsubishi

1. Initialize parameters Before wiring, initialize the parameters. On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by default; Save this state to ensure that this is the status when the control card is powered on again. ...

Mitsubishi PLC commonly used model features Mitsubishi PLC commonly used model features

FX Series PLC: The FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in standard mode. In the meantime, the FX series 5U is suitable for any industry, and is widely used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...

Programming element for Mitsubishi FX2N series PLCs Programming element for Mitsubishi FX2N series PLCs

Each element of the Mitsubishi FX2N series PLC is indicated by a characteristic letter, such as X indicates the input relay, Y indicates the output relay, M indicates the auxiliary relay, T indicates the timer, C indicates the condition element, etc., and these elements have a specified number. ...

Mitsubishi inverter installation reactor advantages Mitsubishi inverter installation reactor advantages

1. Characteristics of the output reactor: 1. It is suitable for reactive power compensation and harmonic control 2. The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and output harmonic current according to the press; 3. Effectively protect the Mitsubishi inverter and improve the power factor, which can block the ...

Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution Mitsubishi participated in the 4th CIIE to introduce the E-JIT green induction solution

On November 5, 2021, the 4th China International Import Expo was grandly held at the National Convention and Exhibition Center in Shanghai. At the 4th CIIE, Mitsubishi Electric's booth was located in Hall 4.1 of the Technical Equipment Zone of the Convention and Exhibition Center, with an exhibition space of 400 square meters. At Mitsubishi Electric's booth, the high-profile event was ...

Mitsubishi PLC control servo motor method Mitsubishi PLC control servo motor method

1. The transistor output type of the FX series generally sends pulses to the servo through the output point of Y0, Y1 or the positioning module, and the speed and direction of the servo depend on the frequency and direction of the pulse in your program. Mitsubishi FX3U series ...

Mitsubishi PLC Explanation Notes on the Final Statement Mitsubishi PLC Explanation Notes on the Final Statement

If the language is a programming language without any explanation, it will be very difficult for the engineer to understand the program again, and some clarification can bring twice the result to the work. There are three types of explanations: notes, statements, and notes. Note: Explain a certain ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top