and Lisi PLC - the difference between PLC and inverter

Create Date: 2024-8-30 12:03:23|Source: HollySys/HollySys

1. The role is different

A PLC (Programmable Logic Controller) is an electronic system designed for digital operations in an industrial environment.

Inverter is a power control equipment that applies frequency conversion technology and microelectronics technology to control AC motors by changing the frequency of the working power supply of the motor.

2. The composition is different

The inverter is mainly composed of rectifier (AC to DC), filtering, inverter (DC to AC), braking unit, drive unit, detection unit, microprocessor unit, etc.

PLC (Programmable Logic Controller) is a digital computing controller with a microprocessor for automatic control, which can load control instructions into memory at any time for storage and execution. The programmable controller is composed of CPU, instruction and data memory, input/output interface, power supply, digital and analog conversion and other functional units.

3. The working principle is different

The inverter adjusts the voltage and frequency of the output power supply by the interruption of the internal IGBT, and provides the required power supply voltage according to the actual needs of the motor, so as to achieve the purpose of energy saving and speed regulation.

The inverter uses a programmable memory to store instructions for performing operations such as logic operations, sequence control, timing, counting, and arithmetic operations, and controls various types of mechanical equipment or production processes through digital or analog inputs and outputs.
and Lisi PLC - the difference between PLC and inverter

More on that
Hollysys DCS - the debugging scheme of DCS system Hollysys DCS - the debugging scheme of DCS system

1. Check before power-on If the cable insulation resistance meets the requirements (greater than 5M ohms), check the cable insulation resistance test record, and spot check the actual measurement if necessary. Check that all power cables, signal cables, and communication buses should be connected. Control stations, operator stations, engineer stations, etc.

Hollysys PLC – How to calculate the analog quantity in PLC Hollysys PLC – How to calculate the analog quantity in PLC

1、-10—10V。 When the voltage of -10V-10V is converted to F448-0BB8Hex (-3000-3000) at 6000 resolution; At 12000 resolution, it is converted to E890—1770Hex (-6000—6000). 2、0—10V。 At a voltage of 0-10V, at a resolution of 12000 ...

HollySys PLC - the usage and principle of PLC programming interrupts HollySys PLC - the usage and principle of PLC programming interrupts

When the PLC understands the interrupt function, it needs to understand the PLC's operating cycle or scan cycle. It is necessary to talk about the process of PLC sequential control loop execution, which is a prerequisite for understanding interruptions and must be mastered. It is divided into three parts, input processing, program processing, and output processing. 1、 ...

Hollysys PLC - maintenance steps of PLC control cabinet Hollysys PLC - maintenance steps of PLC control cabinet

1. Data backup When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...

Hollysys DCS - the connection method between thermocouple and DCS Hollysys DCS - the connection method between thermocouple and DCS

1. The thermocouple uses a compensation wire, and there can be a node in the middle, but the corresponding compensation cable must be used to directly connect to the DCS thermocouple module, such as the LLMUX card in HONEYWELLTPS. Minimize nodes to reduce interference. In addition, in the DCS configuration, it is necessary to select the corresponding thermocouple model, and supplement the ...

Hollyps PLC - the control method of PLC and frequency converter connection Hollyps PLC - the control method of PLC and frequency converter connection

1. Use the analog output module of the PLC to control the analog output module of the inverter The analog output module of the PLC outputs a 0-5V voltage signal or a 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but it needs to be selected and changed.

Hollysys - Contribute to China's green development "Yizhuang Power" Hollysys - Contribute to China's green development "Yizhuang Power"

Facing China's "double carbon" strategic goals, the Beijing Economic and Technological Development Zone is guiding a large number of enterprises to explore the implementation plan of "carbon peak" and "carbon neutrality", and strive to build a number of green factories, green products and green supply chains. Recently, enterprises in the zone and Lisi Group signed a contract for the first time in China to use CO (dioxide...

Hollysys PLC - What are the three large quantities in PLC? Hollysys PLC - What are the three large quantities in PLC?

1. The switching quantity is also called the logical quantity, which means that there are only two values, 0 or 1, ON or OFF. It is the most commonly used control, and controlling it is the advantage of PLC, and it is also the most basic application of PLC. The purpose of switching control is to follow the current input combination with the historical input according to the switching quantity.

HollySys PLC - What places should be avoided when installing PLC? HollySys PLC - What places should be avoided when installing PLC?

(1) The ambient temperature exceeds the range of 0-50 °C; (2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors); (3) direct sunlight; (4) There are corrosive and flammable gases, such as hydrogen chloride, ...

Hollysys PLC - the debugging steps of PLC Hollysys PLC - the debugging steps of PLC

1. Check the circuit according to the drawing (without power transmission) The drawings of the general PLC system include two parts: the drawings in the cabinet and the drawings outside the cabinet; The drawing in the cabinet refers to the wiring diagram inside the cabinet; The out-of-cabinet drawings are the wiring diagrams of all electrical cabinets that are connected out. This part needs to be checked for; 1. Drawings ...

Hollysys PLC - the control function of PLC Hollysys PLC - the control function of PLC

(1) Computing function The computing functions of a simple PLC include logic operation, timing and counting functions; The operation functions of ordinary PLC also include data shift, comparison and other calculation functions; More complex arithmetic functions include algebraic operations, data transmission, etc.; There are also analog PIDs in large PLCs.

Hollysys DCS control system configuration process Hollysys DCS control system configuration process

1. Preliminary preparations Engineering configuration is operated at the engineer station, and before engineering configuration, it is necessary to have the necessary tools and information, specifically: Tools: refers to the hardware environment and software environment used in engineering configuration, usually refers to the ...

Hollysys DCS - What is DCS distributed control system? Hollysys DCS - What is DCS distributed control system?

DCS is the English abbreviation of distributed control system (Distributed Control System), distributed control system is referred to as DCS, which can also be literally translated as "distributed control system" or "distributed computer control system". The decentralized control system is based on the microprocessor, and the control function is decentralized.

Hollysys DCS output module - K-AO02 advantages introduced Hollysys DCS output module - K-AO02 advantages introduced

1. The output accuracy is as high as 0.05%, which greatly improves the operation efficiency of the system. 2. The full-scale output of the channel signal is 0-22.7mA, and the output range is wide; 3. It can be adapted to the enhanced base to achieve channel resistance to 220VAC; 4. It has a perfect channel signal diagnosis function, which can be realized.

Hollysys PLC - nine precautions for the use of PLC Hollysys PLC - nine precautions for the use of PLC

1. PLCZ self-fault judgment In general, PLCs are extremely reliable devices with a very low failure rate. The probability of hardware damage such as the CPU of the PLC or software running errors is almost zero; If the PLC input point is not caused by strong current intrusion, it will hardly be damaged; PLC output relay ...

The difference between Lysys plc - RS232 interface and RS485 interface The difference between Lysys plc - RS232 interface and RS485 interface

1. The physical structure of the interface 1. RS232 interface: One of the computer communication interfaces, usually RS-232 interface in 9 pin (DB-9) or 25 pin (DB-25) form, generally there will be two sets of RS-232 interfaces on personal computers, respectively called COM ...

Troubleshooting steps of Hollysys DCS system Troubleshooting steps of Hollysys DCS system

The steps of DCS system troubleshooting include: (1) Check the fault caused by improper use. Common types of operational faults include operator errors, terminal wiring faults, module installation faults, and power supply failures. (2) Troubleshoot the improper operation of the DCS system ...

Hollysys automation solutions Hollysys automation solutions

Hollysys Automation provides automation solutions for many fields.   Intelligent TCM solutions In order to make the drug achieve the harmony and unity of the doctor's peace of mind, the pharmacist's formula, and the patient's peace of mind, higher requirements are put forward for the pharmacy environment and hospital management. But...

Hollysys safety barriers won excellent products Hollysys safety barriers won excellent products

On December 18, 2020, the "8th Member Congress and 2020 Zhejiang Enterprise Leaders Summit" hosted by Zhejiang Enterprise Confederation, Entrepreneur Association and Industrial Economics Federation (hereinafter referred to as the "Three Associations" of Zhejiang Province) was held in Hangzhou. At the conference, the top 100 in Zhejiang Province in 2020 were commended.

Hollysys' first fully autonomous CBTC application project Hollysys' first fully autonomous CBTC application project

Kunming Changshui International Airport is one of the eight regional hub airports in China and one of the five national large-scale gateway hub airports. With the rapid economic development of Yunnan Province, the aviation business volume of Kunming Airport has grown rapidly.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top