PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

The PLC control cabinet is the final level of equipment in the power distribution system. It mainly protects, supervises and controls the entire circuit, which is convenient for unified management. The power distribution cabinet is a kind of equipment that can reasonably distribute electrical energy and make the circuit easy to open and close. But because it is a circuit device, the requirements for the level of safety protection are very high. Heat dissipation is one of the most important methods. This article concisely introduces how to meet the requirements of heat dissipation in the design and application of PLC control cabinet.

                               PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi

When using PLC control cabinet, equipment with shutters on both sides should be selected as much as possible. The center should not be completely separated. This structure promotes air circulation and increases heat dissipation. Assuming that the user uses it in summer, it should try to prevent long-term operation, because the temperature itself is very high in summer, the equipment itself will also heat up, and the temperature of the PLC control cabinet for long-term operation will be extremely high, which may lead to shortcomings.

The cabinet body of the PLC control cabinet is generally made of stainless steel. This material protects against corrosion and heat reflection. Assuming that the user sprays the insulating paint punctually when using the PLC control cabinet, the heat radiation can be reduced as much as possible, and the role of the PLC control cabinet will be better.

When using a PLC control cabinet, the user also needs to insist on ventilation as much as possible. They should also use methods to prevent the midday sun as much as possible. Assuming that the sandstone was right or wrong, they would have chosen a better location because the temperature above ground is actually higher in the summer, and it always radiates heat to the ground rather than the heat on the sandstone ground. Relatively small, it can cut the generation of heat.

Many people can really understand the general planning of PLC control cabinets. But the widespread use of low-voltage distribution cabinets is surprising. We all know that the use of PLC control cabinet is suitable for factories, mines, enterprises, shopping malls, hotels, schools, airports, ports, hospitals, high-rise buildings, day areas and other occasions, communication 50Hz, rated operating voltage for communication 380V low-voltage power grid system. M, as power, lighting power distribution and motor control, suitable for rooms. Equipment for power distribution equipment on interior walls and exterior floors.

The use of PLC control cabinets is also suitable for communication 50Hz. Fire pump control, submersible pump control, fire fan control, fan control, lighting PLC control cabinet control are all selected power systems with voltage below 500V. The control methods include direct start control, star delta step-down start control, auto-coupling step-down start control and frequency converter. Control methods such as initiation control and soft initiation control can also be used as blocking switches and fuse switches.

In hot climates, people's electricity consumption increases dramatically. Because of overheating, the insulation of the wires will be burned out, announcing the stench of burnt skin and plastic incineration. This condition can be caused by overheating of the wires. The switch should be turned off as soon as it is discovered, and the cause of the overheating of the wire should also be identified. In everyday life, it is assumed that the line is found to be aging and damaged, and it is necessary to replace it in time to prevent damage in the future.

In order to prevent problems in the PLC control cabinet in the high temperature climate in summer, it is necessary to check the electrical wiring of the home or unit on time to eliminate hidden dangers in time. During equipment and construction, it is necessary to prevent scratches, abrasions, and bruises of conductor insulators. Pay attention to the robustness of the wire splices and the robustness of the insulating bandage. In places with special humidity, high temperatures or corrosive substances, it is forbidden to lay insulated wires in the open air. Casing wiring is selected. In dusty localities, wiring and insulation boards should be arranged on time to prevent oil pollution. Stop the indiscriminate pulling of wires. When the equipment wire, the wire of the corresponding section should be reasonably selected according to the load of the electrical equipment. Check the line fuse on time, choose the right one, and don't adjust the fuse at will, let alone replace the fuse with aluminum and copper wires. Punctually check whether the connection points on the line are robust and reliable, and no flammable materials should be placed near the line integrator. In order to better provide us with the above facilities, the PLC control cabinet is of great help to us.

More on that
Introduction of Mitsubishi servo motor Introduction of Mitsubishi servo motor

Servo motor refers to the engine that controls the operation of mechanical components in the servo system, and is a kind of auxiliary motor indirect transmission device. The servo motor can make the control speed, azimuth accuracy is very precise, and can convert the voltage signal into torque and speed to drive the control target. Servo motor rotor speed ...

Installation and maintenance of Mitsubishi inverters Installation and maintenance of Mitsubishi inverters

1. Mitsubishi inverter is more and more widely used because of a series of advantages such as wide speed regulation range, high speed regulation accuracy, fast dynamic response, high work efficiency, convenient operation and easy interface with other equipment. Because of the high common sense content of Mitsubishi inverter and the messy technology, how to use Mitsubishi inverter well...

Confirmation and clearing of Mitsubishi inverter alarm history Confirmation and clearing of Mitsubishi inverter alarm history

When the FR-CS80 inverter detects an abnormality, it will display an error message or alarm in the operation panel according to the abnormal content, or maintain the function action and block the output of the inverter. When maintaining a function operation, please deal with the cause of its operation before resetting the inverter, and then start working. ...

Mitsubishi servo system common alarms and solutions Mitsubishi servo system common alarms and solutions

The use of Mitsubishi AC servo system is mainly composed of three series: MR-ES, MR-J2S, MR-J3. In general, the cause of the fault can be preliminarily determined based on the code displayed on the servo drive, and then troubleshooting: 1、AL. E6 - Indicates ...

Mitsubishi FX series PLC master control command Mitsubishi FX series PLC master control command

The FX2N has a total of 27 fundamental logic instructions, including 20 fundamental logic instructions of some sub-series PLCs. Master Control Command (MC/MCR) (1) MC (Master Control Command) for common tandem contacts ...

Mitsubishi Electric will introduce the T-series 2.0kV IGBT module for industrial use Mitsubishi Electric will introduce the T-series 2.0kV IGBT module for industrial use

Tokyo, June 9, 2021 – Mitsubishi announced the upcoming launch of its industrial T-series 2.0kV insulated gate bipolar transistor (IGBT) module, the world's first IGBT1 with a 2.0kV withstand voltage, June 30. This module is ideally suited to increase the power of renewable energy power converters ...

Mitsubishi Electric CNC numerical control system grounding specification Mitsubishi Electric CNC numerical control system grounding specification

What is the effect of machine tool grounding? 1. Insist that the machine shell and the ground insist on the same voltage. 2. In the event of abnormal external voltage or leakage, the maintenance personnel and the machine tool will not be damaged electrically. 3. Avoid damage to CNC equipment caused by external voltages such as surges. 4. ...

Mitsubishi Electric Solutions serves the entire process of lithium battery production Mitsubishi Electric Solutions serves the entire process of lithium battery production

Mitsubishi Electric's MES system MELNAVI has a standard database, which can meet the needs of the 11 major functions required by MES, and also supports flexible secondary development, which can easily connect the upper ERP and lower automation products in a short time, and can also be connected to other APS scheduling software and analysis systems. ...

Mitsubishi PLC Explanation Notes on the Final Statement Mitsubishi PLC Explanation Notes on the Final Statement

If the language is a programming language without any explanation, it will be very difficult for the engineer to understand the program again, and some clarification can bring twice the result to the work. There are three types of explanations: notes, statements, and notes. Note: Explain a certain ...

Advantages and disadvantages of different output types of PLC – Mitsubishi Advantages and disadvantages of different output types of PLC – Mitsubishi

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The big advantage is that it is accustomed to high-frequency action, and the echo time is short, generally about 0.2ms, but ...

Mitsubishi A800 series inverter realizes motor self-learning Mitsubishi A800 series inverter realizes motor self-learning

Set it up as follows: Press PU/EXT to switch to PU format Pr.9 = additional current of the motor Pr.71=3 (ordinary motor) or 13 (constant torque motor) Pr.80 = motor power Pr.81 = number of poles of the motor ( ...

Introduction to the selection conditions of Mitsubishi A840 series inverters Introduction to the selection conditions of Mitsubishi A840 series inverters

Q: When will I choose the A840 series inverter? A: A800 series inverters are generally used in heavy-duty occupations, such as lifting occupations, mixer occupations will use A800 series. At the same time, it is a vector inverter, so customers need to do closed-loop speed control, torque control may ...

Mitsubishi servo motor is now commonly used Mitsubishi servo motor is now commonly used

1. Torque control: Torque control is based on external simulation simulation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load on the motor shaft is less than 2.5Nm, ...

Introduction of Mitsubishi PLC series Introduction of Mitsubishi PLC series

1. Main substrate There are a variety of models such as Q32SB, Q33SB, Q35SB, Q33B, Q35B, Q38B, Q312B and other main substrates for Q series PLC, and the meaning of the model is as follows: In the meantime, the "S" stands for ultra-thin main substrate, and only Q61SP power modules can be used, and they cannot be ...

Mitsubishi MELSEC iQ-F makes IoT a simple one Mitsubishi MELSEC iQ-F makes IoT a simple one

The MELSEC iQ-F series of small PLCs completes the high-speed system bus, supports a variety of networks, enriches the built-in functions, and makes it more convenient to use. From stand-alone use to network-based system proposals, we strongly support the needs of customers for "cutting-edge products in the manufacturing industry". Using the MELSEC iQ-F...

Advantages and applications of servo motors - Mitsubishi Advantages and applications of servo motors - Mitsubishi

First of all, what are the advantages of servo motors compared with other motors (such as stepper motors): 1. Accuracy: Closed-loop control of azimuth, speed and torque is realized; Overcome the problem of stepper motor out-of-step; 2. Speed: high speed ...

Mitsubishi FX series PLC error command and solution Mitsubishi FX series PLC error command and solution

1. Error message: NO ERROR--No abnormal error occurs Abnormal content and cause: No abnormal occurrence Solution: Check whether the cable connection between the host and the I/O expansion base/module is normal 2. Error message: ...

Advantages of Mitsubishi inverter installation reactor Advantages of Mitsubishi inverter installation reactor

Features of the output reactor: 1. It is suitable for reactive power compensation and harmonic management 2. The primary effect of the output reactor is to compensate for the influence of long-line distributed capacitance, and output harmonic current according to the press; 3. Effectively maintain Mitsubishi inverters and improve the power factor, which can thwart the ...

Debugging method of servo motor - Mitsubishi Debugging method of servo motor - Mitsubishi

1. Initialize parameters Before wiring, initialize the parameters. On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by default; Save this state to ensure that this is the status when the control card is powered on again. ...

Mitsubishi servo motor for precise positioning Mitsubishi servo motor for precise positioning

The servo?mechanism is a process control system that enables the output of the direction, direction, and condition of the block to change at will according to the input overall goal (or given value). How to finish the Mitsubishi servo motor ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top