1. Main substrate
There are a variety of models such as Q32SB, Q33SB, Q35SB, Q33B, Q35B, Q38B, Q312B and other main substrates for Q series PLC, and the meaning of the model is as follows:
In the meantime, the "S" stands for the ultra-thin main board, and only the Q61SP power module can be used, and the expansion module cannot be connected. The number of modules that can be installed on the substrate refers to the number of I/O modules that can be installed on the substrate, excluding the device positions of the CPU module and the power module.
2. Expansion substrate
The expansion board is used to install the expansion module of the PLC to add the number of I/O points of the system. The expansion substrate of Q series PLC can be divided into:
1), demand power module: Q52B, Q55B
2) No need for power module: Q63B, Q65B, Q68B, Q612B
High-performance CPUs can also be procured with expansion boards for the A1S series.
3. Set the number of extended progressions
When the PLC needs to be expanded, the expansion address (number of stages) should be set on the substrate, and the expansion address should be set next to the expansion cable connector where the switch is located on the substrate.
Mitsubishi Q series substrates, Mitsubishi Q series expansion boards
|
More on that
|
Mitsubishi inverter FR-A800 operating environment
Comfortable operating environment for Mitsubishi inverter FR-A800
|
|
PLC circuit debugging precautions - Mitsubishi
1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the state; The positive logic criterion is usually used, that is, when the input and output are live, it is in the "ON" state and the data value is "1"; Conversely, when the input and output are powered off, it is in the "OFF" state and the data value is "0". Such...
|
|
Pay attention to the wiring of the Mitsubishi PLCI/O terminal
1. Enter the wiring
(1) The input wiring should generally not exceed 30 meters. However, if the environmental disturbance is small and the voltage drop is not large, the input wiring can be appropriately longer.
(2) The input/output lines cannot be separated by the same cable, and the input/output lines should be separated.
(3) As far as possible, choose normally open ...
|
|
PLC troubleshooting method - Mitsubishi
1. If the PLC stops in the middle of some outputs where the output is excited, then look for the signal that caused the next operation (input, timer, line, drum manipulator, etc.). The programmer will show the ON/OFF status of that signal.
...
|
|
Advantages and disadvantages of different output types of PLC – Mitsubishi
The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types?
(1) Transistor output:
The big advantage is that it is accustomed to high-frequency action, and the echo time is short, generally about 0.2ms, but ...
|
|
There are three major classifications of inverters - Mitsubishi inverters
There are several ways to classify frequency converters:
According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
In accordance with the ...
|
|
Characteristics of servos and advantages of Mitsubishi servos
The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system.
|
|
Differences in the output form of Mitsubishi PLC
Generally, there are three types of Mitsubishi PLC output circuit methods, namely: relay output type, transistor output type and thyristor output type. So what are the characteristics of each of them?
First, the relay output circuit
Use of relays ...
|
|
Analysis of the conversion principle of Mitsubishi PLC
1. The digital-to-analog converter is a system that converts digital signals into imitation signals, which can generally be completed by low-pass filtering. The digital signal is decoded in the first line, that is, the digital code is converted into the corresponding level to form a stepped signal, and then the low-pass filter is carried out.
According to the signal and system ...
|
|
Precautions for the use of Mitsubishi servo motor with brake
1. Occasions with brake servo motors:
The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...
|
|
Seven-step method for PLC project debugging - Mitsubishi PLC
Many novices in the electrical industry are not sure how to start debugging after completing the planning links such as electrical control cabinets and PLC programs. Perhaps some people due to inappropriate debugging methods have led to PLC burning and other problems, so how should the planned electrical system be debugged? Follow these seven steps. ...
|
|
Mitsubishi inverter basic questions and answers
1. Question: What is the type of RS485 to RS232C converter used by Mitsubishi inverter for communication?
Solution: FA-T-RS40* Mitsubishi inverter is available.
2. Question: Mitsubishi inverter frequency external potentiometer is given, and the external potential recommended to be used ...
|
|
Mitsubishi inverter setting parameter adjustment method
Mitsubishi inverter has many setting parameters, each parameter has a certain selection scale, and the inverter can not work normally due to improper setting of a single parameter in the application. Let's take a look at the Mitsubishi inverter parameter setting operation.
...
|
|
Introduction to the Mitsubishi PLC encryption process method
The encryption process is as follows:
** Open the serial port for the first time
[00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here)
[00000000] IOCTL_SERIAL_SET_LINE_CONTROL StopBits: 1, Parity: Ev ...
|
|
The weight conversion method of the Mitsubishi weigh module
Component conversion is a process in which an analog signal (load converter output voltage) input from outside the programmable controller is converted into a digital output value and a total component output value, and then stored in buffer memory. After the conversion process, the conversion completion (XE) will change to ON, and the transformation completion mark (Un\G1 ...
|
|
PLC Programming Recommendations – Mitsubishi PLC
1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many hours on the screen that require "manual", "active" and other control forms (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1 MOV will be changed to a ...
|
|
A brief description of Mitsubishi MELIPC industrial control products
MELIPC's intelligent industrial control product system includes MI50000 analysis categories, MI2000 monitoring strain, and MI1000 gateway category, forming a full range of data collection, processing, and transmission solutions between the FA production site and the IT system, and using edge accounting to complete the self-discipline and sloppy IoT layout.
|
|
The matching relationship between the inverter and the motor - Mitsubishi
It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors are also smaller in some functions according to the segmentation. Such as Sanyo ...
|
|
Mitsubishi tension controller principle
1. Tension Manipulator Principle - Introduction
The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the human ability to ...
|
|