Those who know more about Delta's automation know that Delta's inverters have two main series: "M300" and "C2000".
"Compact Inverter M300 Series": This series has been introduced many times before, including MS300 (standard general-purpose type), MH300 (high function), ME300 (economical type), and its power range is 0.2-75KW. With the full withdrawal of the white shell machine represented by the M series in September this year, the M300 series has also become Delta's leading model in the field of industrial machinery.
As a "standard inverter, the C2000 series" covers a complete power range of small, medium and large, and the C2000 series is undoubtedly a more suitable choice when more power and greater torque are required.
C Dynasty inverter
Since its launch in 2010, the C2000 inverter has become a huge fan among its fellow customers. In 2019, Delta developed the "C2000+ inverter" on its basis, which integrates the advantages of the C clan: modular design, common DC bus, synchronous asynchronous motor dual-machine integrated control, multi-purpose monitoring software, and strong panel function, etc., which made the C clan a strong inverter at that time.
Overload can be greatly improved
The significant enhancement of overload capability is one of the key functional enhancements of the C2000+. This is also one of the indicators that are valued in the market use of normative inverters. Originally, the Delta C2000 could complete 120% load in 60 seconds and 150% load in 3 seconds under the standard form. In the heavy-duty mode, it can be loaded at 150% for 60 seconds, and at 180% for 3 seconds. This is now beyond the function of mainstream general-purpose inverters in Europe and the United States. However, in practice, there will still be some use cases that need to be expanded by one level.
Therefore, the C2000+ once again strengthens this function, and the standard form can complete the load of 150% for 60 seconds, and the load of 180% for 3 seconds; In the SHD form, it reaches 150% for 60 seconds and 200% for 3 seconds.
Even in occupations with high requirements for instantaneous loads, such as injection molding and punch presses, the C2000+ can easily cope with excellent overload capabilities and high starting torques without the need to expand the configuration by one gear.
The power range of the 460V model of C2000+ has been expanded from the original 0.75KW-450KW to 560KW high, with high power and high torque, and the characteristic functions of different occupations such as rubber and plastic, construction, metal processing, and transfer machinery are also able to meet the needs of most occupations.
Protection can be significantly strengthened
Another major change in the C2000+ is the improvement of overall protection.
First of all, the C2000+ will increase the original IP51 cooling fan of the C2000 to IP55 level, which not only further strengthens the heat dissipation function, but also improves the protection of dust, oil mist, salt spray, etc. by 3-30 times. The use of polished heat sinks with wider spacing further reduces the accumulation of dust lint. Combined with the classic device method of extending the heat dissipation backplate to the outside of the cabinet, the heat dissipation and protection effect are more and more excellent.
Together, the C2000+ adopts a reinforced PCB board coating that complies with the international standard IEC60721-3-3class 3C3. It can maintain electronic components from corrosive environmental gases, and in addition to improving the protection of C2000+, it also broadens its use in harsh environments and special scenarios such as sewage treatment.
CE/UL/cUL global safety certification proves the excellent quality function of C2000+.
Expansion of high-speed network communications
High-speed network communication is also a must for today's inverter equipment.
The C2000 originally supports CANopen, Modbus TCP, EtherNET/IP, DeviceNET, PROFIBUS and other communication protocols, while the C2000+ adds EtherCAT and PROFINET, making data transmission and control faster and more efficient, and more closely cooperating with the Internet of Things system.
The operation is fast and user-friendly
In terms of operation and use, the C2000+ inherits the speed and humanization of Delta's C clan.
The visual LCD operation panel and the collaborative boot wizard function allow the operator to easily complete the parameter setting. The C2000+ occupation parameter combination function can directly select different occupations to use and browse the parameters, which greatly simplifies the operation process. The parameter replication function makes batch debugging extremely easy. In addition, Delta's signature multi-Chinese function has also brought convenience to many multinational customers.
In the past year since its launch, the C2000+ inverter with strong functionality has proven itself to be efficient and reliable in collaboration with many customer companions. The strategy of improving quality without raising prices also makes C2000+ a Delta inverter worth starting.
|
More on that
|
Requires an inverter speed control application – Delta
Inverter is a kind of speed regulation equipment, where is there a place to use motor speed regulation, especially asynchronous motor speed regulation, will use inverter, now it is mainly used in industrial equipment on a large scale, because the motor is the heart of industry, and three-phase asynchronous motor occupies the vast majority of the share, ...
|
|
A brief description of the selection of Delta inverters
Delta's inverter series are as follows:
1:VFD-EL,VFD-S,VFD-L,VFD-C200
Voltage 220V, 380V, power scale 100W-7.5kw
The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fan pumps, food and medical ...
|
|
EMC Filter Installation Considerations – Delta
All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...
|
|
Tips and methods for using PLC - Delta PLC
First, the selection of output module
The output modules are divided into transistors, triacs, and contact types:
(1) The switching speed of the transistor type is fast (generally 0.2ms), but the load can be small, about 0.2-0.3A, 24VDC, suitable for fast switching, signal contact...
|
|
Servo motor speed improvement method - Delta
When many engineers debug servo motors, they often have such a problem: why is my servo motor so slow, how can I improve the speed, and how much can the maximum speed reach? The basis for the confirmation of the speed method of the servo motor: the speed of the servo motor.
...
|
|
The cause of the failure of the main power supply circuit of the inverter - Delta
We really talked a lot about the relevant knowledge of inverter repair, but we talked less about the main reasons for protecting the main power supply circuit. Then take a look at the introduction below:
When there is a fault in the main power supply circuit of the inverter, in addition to selecting each component to match the corresponding power, it should also ...
|
|
The frequency of the inverter is given in a given way - Delta
The main way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps are required to complete the output frequency controllability? One of the main points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
The inverter has a built-in PLC function - Delta
PLC progressive scanning standard work preparation.
Abundant programming language: instruction statements; ladder diagram; SFC。
Abundant instruction statements: 45 instruction varieties, including 28 root instructions and 17 usage instructions.
350 step law capacity.
uS-level root directives ...
|
|
Delta's Smart series of micro-modules help transform high-speed tunnel networks
Recently, Delta's Smart series of micro-modular data center processing solutions successfully assisted the smooth implementation of a provincial tunnel network transformation project in a province. The project has set up a series of safety operation networks such as video, lights, signals, networks, rescues, and alarms for the safe operation of key roads in the province.
|
|
Delta's M series inverter communication parameter address problem
In Delta's M series inverters, the parameter address 2000H corresponds to abort, start, JOG, and forward, rotation, and change direction. Why is "aborted" at the time of writing the program H01, "start" is H10, "forward" is H12, and "rotation" is H22.
...
|
|
Delta's PLC-Based motion controller AX3 series
With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...
|
|
Delta's M300 series inverters are used in primary and auxiliary frequency applications
I. Introduction
Some devices will have many transmission organizations, and it is impossible for the transmission organization to achieve 100% speed synchronization, so it is necessary to introduce ------ The final motor speed of the pendulum roller is *** := main speed + (+-auxiliary correction change)
Use the site ...
|
|
What are the problems of the inverter if it is not used for a long time - Delta
Most inverter brand products can rely on the heat of internal electrical components to remove moisture during normal use. If you don't use it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...
|
|
How the components of the inverter work – Delta
1. Inverter element - rectifier
Since it is difficult to change the frequency of the communication sine wave in the form of communication, the first operation of the inverter is to convert the waveform into direct current. To make it look like an AC, it is relatively easy to operate the DC. The most important component of all inverters is a ...
|
|
Routine maintenance of Delta UPS power supply equipment
The inspection personnel should record the operation status, voltage and current values of the UPS every day, and deal with the problems in a timely manner.
Check whether the traffic lights are working properly;
Keep the outside of the battery clean;
Check the operating status of the battery pack ...
|
|
Introduction of incoming reactor for inverter - Delta
Reactors are also called inductors, and when a conductor is energized, a magnetic field will be generated in a certain space scale occupied by it, so all electrical conductors that can carry current have inductance in a general sense. However, the inductance of the energized long straight conductor is small, and the magnetic field generated is not strong, so the actual reactor is conductive.
|
|
Precautions for inverter selection - Delta
The selection of the inverter is mainly determined by the load characteristics of the drive and the actual working current of the motor, in addition to the following precautions:
1. The environment is suitable for some high temperature (higher than 50 degrees) and high altitude (higher than 1000 meters).
|
|
The function in the process of using the inverter cabinet - Delta
Inverter cabinet is an industrial control equipment that can be widely used in fire fighting, daily constant pressure water supply and drainage, agricultural sprinkler irrigation pipe network pressurization, urban music fountain active water supply control, HVAC cold and hot water circulation control and other occasions. In addition, it also has a variety of maintenance functions such as: short circuit, overload, phase loss, etc.
|
|
Advantages of sensorless vector control - Delta inverter
Excellent open-loop speed control without slip compensation
There is high torque at low degree, so there is no need to supply too much torque to enhance c. Lower loss, higher power
Higher power echoes – especially for stepped loads
Big...
|
|
Delta's LOYTECIoT building management platform helps Yili Group reduce costs
Intelligent houses are selected with fully automatic automatic control systems to consider the diverse requirements of community owners, managers and users in housing management methods. In the new project of Yili Group's Food Science R&D Trend Management Center, under the framework of opening to the outside world, Damei has made use of Loytec ...
|
|