Wide air volume range: 20-900m3/h
Innovative diagonal flow fan and brushless DC EC motor technology for higher air flow and uniform distribution of cold air
Comes with an interface module for controlling and monitoring fans
The standard degree of protection is IP54, up to IP56 with a water spray cover
Models with EMC are available
The fan can be installed in front and back, which is convenient for flexible switching between suction and exhaust
|
More on that
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is Phase Order?
Answer: It is the order of the phases, which is the sequence in which the instantaneous value of alternating current changes from negative to positive through zero
What is the safety distance of the human body grounding point when a grounding fault occurs in high-voltage equipment?
A: Indoor should be larger than 4 m, outdoor should be larger than 8 ...
|
|
How to set the temperature of the Rittal air conditioner
1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters.
2. High temperature alarm: ...
|
|
Rittal cabinet - distribution cabinet installation method, installation process and precautions
First, the construction process
Equipment unpacking inspection→ equipment handling, → cabinet (plate), basic installation, → above the cabinet (plate), bus preparation, → cabinet (plate), secondary circuit wiring, → cabinet (plate) test adjustment, → power transmission operation acceptance
Second, the construction process
1. Equipment unpacking inspection, installation ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is a control device?
Answer: It is mainly used to control the switching appliances of the powered equipment and the combination of control, detection, protection and regulation equipment associated with these switching appliances.
What is Overcurrent?
A: Any electricity that exceeds the rated current.
...
|
|
Rittal presents a number of green and innovative sanitary cabinets at CBST
On April 7, 2023, the 11th CBST China International Beverage Industry Technology Exhibition was grandly held at the Shanghai New International Expo Center.
As a practitioner of the concept of "intelligent manufacturing" in Germany, Rittal brings many green and innovative sanitary cabinet systems and temperature control solutions.
|
|
Rittal cabinets – judgment and handling of high-voltage switchgear closing faults
Closing faults can be divided into electrical faults and mechanical faults. There are two types of closing methods: manual and electric. Failure to close manually is generally a mechanical failure. Manual can be closed, electric can not close is an electrical fault.
1. Protection action: The protection action has been analyzed in front to trip the switch. ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the principles for drawing and reading the schematic diagram of electrical control circuits?
Answer: A. The schematic diagram is generally divided into power supply circuit, main circuit, control circuit, signal circuit and lighting circuit.
B. In the schematic diagram, the position of the contacts of each electrical appliance is according to the ...
|
|
Rittal cables – the meaning of the first letter in the number of the control cable
First of all, the number of the control cable often starts with the letter "C", which indicates that the control cable is specially designed to connect different sensors and control devices as a medium for signal transmission. This kind of cable can transmit data signals, and has a certain resistance to wear and chemical corrosion, so it is widely ...
|
|
Rittal cables – common faults in power cables
Short-circuit fault: There are two-phase short circuits and three-phase short circuits, which are mostly caused by hidden dangers left in the manufacturing process.
Grounding fault: one or more cores of the cable break down to the ground, and the insulation resistance is lower than 10kΩ is called low-resistance grounding, and higher than 10kΩ is called high-resistance grounding. Mainly due to cable corrosion, lead ...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (1-10)
1. What is TT, IN, IT system?
A: The TT method refers to a protection system that directly grounds the metal shell of electrical equipment, which is called a protective grounding system, also known as a TT system. The TN method is a protection system that connects the metal shell of the electrical equipment with the working neutral line, called ...
|
|
Introducing the Rittal Product Configuration System (RiCS).
The Rittal Configurator (RiCS) is a new system configurator for the Rittal system product. It will allow you to quickly select a custom-configured cabinet that meets your application needs. During the configuration process, you can view the configuration in real time through the visual 3D model. After the configuration is complete ...
|
|
Rittal Cables – an introduction to the structure of industrial control cables
1. Conductor
It is the main component of the product to play its use function, and it is to transmit electricity or information, that is, to transmit electric current or electromagnetic waves on the conductor. The conductor is the basic and indispensable main component of the product for the transmission of electric current or electromagnetic wave information.
2. Insulation ...
|
|
Rittal cabinets – what are the technical requirements for the cabinets?
1. It should have good technical performance. The structure of the cabinet should be designed according to the electrical and mechanical properties of the equipment and the requirements of the use environment, so as to ensure that the structure of the cabinet has good stiffness and strength, as well as good electromagnetic isolation, grounding, noise isolation, ...
|
|
Rittal Cables - Causes and countermeasures of line faults of power cables
External damage: In the process of storage, transportation, laying and operation of cables, they may suffer external damage, especially the directly buried cables that have been run, and are prone to damage in the ground construction of other projects. Such accidents often account for 50% of cable accidents. In order to avoid such accidents, in addition to strengthening the cable ...
|
|
Rittal cabinets – the specifications of server cabinets
Server cabinets have requirements in terms of depth, height, and load-bearing capacity. There are three heights of 2.0 meters, 1.8 meters and 1.6 meters; The width is 800mm, 700mm or 600mm; There are three depths: 700mm, 800mm and 900mm.
Can be configured: special fixed pallet, special ...
|
|
How to use Rittal cabinets
1. Tie the cable tie at the beginning of the root of the cable with a cable tie, if there are too many cables, the number of the network cable is divided into two or many parts from the center, but the demand ensures that each part of the network cable is connected, because the next step is simple.
2. According to ...
|
|
A basic introduction to a very popular explosion-proof box in Rittal
As a commonly used box in Rittal, many users do not understand the material and structure of this series of boxes.
Now I would like to introduce the Rittal explosion-proof enclosure
Apply:
– Zones 1 and 2 or Zones 21 and 22 according to 94/9/EG
– Ambient temperature range: -30°C.
|
|
Rittal fans – analysis of the reasons why cooling fans do not rotate
1. Power failure: The power supply of the fan fails, such as the power cord is disconnected, the power plug is loose, etc., which will cause the current to fail to transmit normally, resulting in the fan stopping and rotating.
2. The temperature is too low: Some heat dissipation windbreakers have a temperature protection function, when the temperature is too low, the fan will automatically ...
|
|
What are Rittal cabinets used for?
1. The cabinet is generally made of cold-rolled steel plate or alloy to store the computer and related control equipment, which can provide protection for the storage equipment, shield electromagnetic interference, arrange the equipment in an orderly and neat manner, and facilitate the maintenance of the equipment in the future. Cabinets are generally divided into server cabinets, network machines, etc.
|
|
What are the advantages of Rittal enclosure processing – sheet metal cabinets?
The development of sheet metal cabinet and chassis processing industry is getting bigger and bigger, which is due to the rapid development of society, the popularity of high-tech products, server cabinets, computer main chassis, equipment shells, etc. What are the advantages of sheet metal cabinet enclosures?
1. Cabinet and chassis products provide space for ...
|
|