1. Look at the packaging, the wires of the national standard are often better, neat, and have a sense of quality when you hold them.
2. To open the package and take a look at the wires inside, the wire of the national standard is 1.5——-6 square wires The wire requirements are skin thickness (insulation thickness) is 0.7mm, too thick is non-standard, the corresponding inner core is definitely not enough, the wire skin you can pull hard, it is not easy to tear is generally the national standard
3. Burn it with fire and extinguish it within 5s after leaving, and it has a certain flame retardant function for the national standard line.
4. Look at the inner core, the higher the brightness of the inner core (copper), the better the copper, and the luminosity is uniform, shiny, and there is no sense of hierarchy. The national standard requires that the inner core must be made of oxygen-free copper. Non-standard such as black rod copper, there may be potential accidents.
5. The thickness of the inner core has certain requirements in the country, but it is not very strict. But there are not many mistakes, just a small point, and the error is generally not visible with the eye.
6. Length, the state does not force the rice, but there are many manufacturers who also beat the rice, and the rice is not necessarily the national standard, but the general national standard generally does not beat the rice. Non-standard rice is just a means.
7. The state stipulates that there must be a certain logo on the wire, and the maximum will not exceed 500mm, and the next same logo will be played, and there are generally product trademarks, manufacturer names, implementation standards, etc.
|
More on that
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the main technical parameters of the fuse?
Answer: A. Rated voltage, B. Rated current, C. Breaking capacity, D. Melting characteristics, E. Overvoltage.
What are the main products of low-voltage power distribution equipment?
Answer: Low-voltage distribution panels, switch cabinets, switch boards, lighting boxes, power boxes and electrical ...
|
|
Rittal Cables – an introduction to the advantages of industrial control cables
Fulfillment of the requirements of many electrical appliances: In the manufacture of industrial control cables, the relevant standards for the transmission of various information are fully considered. This ensures that the industrial control cables can meet the performance requirements of many electrical appliances in their daily work.
Abrasion Resistance: Industrial Control ...
|
|
Rittal cabinets – what electrical components are included in the electrical cabinet?
1 Circuit breaker
Low-voltage circuit breakers, also known as automatic air switches, can be switched on and off manually, and can be used to distribute electrical energy, start asynchronous motors infrequently, and protect power lines and motors. In the event of a severe overload, short circuit, or undervoltage fault, the circuit can be automatically shut down.
2 Contactors
...
|
|
Rittal Cables - Causes and countermeasures of line faults of power cables
External damage: In the process of storage, transportation, laying and operation of cables, they may suffer external damage, especially the directly buried cables that have been run, and are prone to damage in the ground construction of other projects. Such accidents often account for 50% of cable accidents. In order to avoid such accidents, in addition to strengthening the cable ...
|
|
What are the main classifications of Rittal cables – power cables?
Classified by voltage level
According to the voltage level, it can be divided into medium and low voltage power cables (35 thousand volts and below), high-voltage cables (above 110 thousand volts), ultra-high voltage cables (275-800 thousand volts) and ultra-high voltage cables (1000 thousand volts and above). In addition, it can also be divided into AC ...
|
|
Cable management components for Rittal's IT cabinets
An IT cabinet generally needs to arrange a lot of cables, including strong current cables for power supply equipment, optical fibers used for communication, and weak current cables for signal transmission. So many cables in a cabinet if not well packed up form a clutter of cables in the cabinet, and then ...
|
|
Rittal Cables – What do you need to pay attention to when wiring industrial control cables?
1. The weight of the cable in the industrial control cable drag chain should be evenly distributed, so as to avoid accidents caused by uneven weight during operation, and the principle of distributing the cable is that the heavier one is located on both sides and the lighter one is located in the middle. All industrial control cables must be securely fastened to one end of the energy chain, so that ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the main differences between electronic control equipment and power distribution equipment products?
Answer: The function of electronic control equipment is mainly control, and the function of power distribution equipment is mainly transmission.
How much is the external design of domestic electronic control equipment products?
Answer: Control panel, control cabinet, control box and console ...
|
|
Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant
A new A320 Airbus aircraft must pass rigorous testing before it can be put into service, so to ensure a smooth flight, not only the aircraft itself needs to be protected from overheating, but also the test hardware needs to be properly protected. Airbus uses Rittal Blue e+ cooling units to make it ...
|
|
Five hidden details you didn't know about Rittal cabinets and common Q&A
Five details that are easy to overlook:
One of the hidden details: steel
The most basic thing of a cabinet is to look at the steel, the Rittal standard cabinet is made of section steel, there are many masters who understand the cabinet to understand, the steel plate must be thick, just knock it with your fingers. General ...
|
|
Rittal wall-mounted air conditioner with high energy efficiency Blue e+ 1.6-5.8 kW with an average energy saving of 75%
Rittal wall-mounted air conditioner Blue e+ 1.6-5.8 kW
Product model 3185.830
The energy-efficient Blue e+ wall-mounted cooling unit with capacities ranging from 1600 W to 5800 W. Energy savings of 75% on average due to the use of speed control components and heat pipe technology. There are carbon steel and ...
|
|
Description of the models of Rittal cabinet air conditioners
Here are some of the models of Rittal cabinet air conditioners:
SK3368220 air conditioner RBT3368220 300 W, 220V
SK3368320 air conditioner RBT3368320 500 W, 220V
SK3368520 air conditioner RBT3368520 1000W, 220V
SK3368620 air conditioning RBT3368620 ...
|
|
Analysis of the fault codes of the Rittal cabinet air conditioner
1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect;
2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small;
3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...
|
|
With the Rittal VX SE freestanding cabinet, the possibilities are endless
How to make it simpler?
How can safety be paramount?
Still worried about not being able to reduce the cost of the system?
The most suitable cabinet system is just a dream?
You've got you covered – faster, safer, simpler, compatible, and versatile...
|
|
Rittal cables – what are the types of industrial wires and cables commonly used?
Industrial wires and cables include single-core wires and cables, rubber cables, shielded control cables, flame-retardant cables, fire-resistant cables, etc.
Single-core wire and cable
It means that there is only one conductor in the insulation layer, the common BV wire, and B represents the wiring; V stands for insulating polyvinyl chloride. Suitable for AC ...
|
|
Rittal cabinets – solutions for cooling network cabinets
1. Deliver the cold air to the network cabinet: Because the equipment in the cabinet needs the air conditioning the most.
2. Deliver the cold air to the front of the network cabinet: because the cold air can only enter the module server chassis from the front of the server to play a role in heat exchange.
3. Precisely adjust the ...
|
|
Rittal cables – type descriptions for power cables
The model of the power cable
1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...
|
|
Rittal cabinets – the cause of moisture in electrical cabinets
(1) The cause of moisture in the cabinet
1) Environment shutdown. The ring main unit or the opening and closing station itself is a closed environment, because of the poor ventilation conditions, it is easy to gather moisture and generate condensation, and there are many large buildings today in order to reduce the occupied area, the opening and closing station, the power distribution room is built in the basement. Cause...
|
|
Rittal toroidal transformers Primary connection 115 V/400 V
Rittal toroidal transformer primary connection 115 V/400 V
Product Model: 3201.970
Power supply for wall-mounted air/water heat exchangers in 230 V sizes. A 115 V or 400 V main connector is available.
Product Description: Wall for 230 V Specification
|
|
Rittal cables – the meaning of the first letter in the number of the control cable
First of all, the number of the control cable often starts with the letter "C", which indicates that the control cable is specially designed to connect different sensors and control devices as a medium for signal transmission. This kind of cable can transmit data signals, and has a certain resistance to wear and chemical corrosion, so it is widely ...
|
|