Rittal Cables – What are the causes of faults in wires and cables?

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

1. External force damage. Judging from the operation analysis in recent years, especially in Haipu East, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Civil construction on directly buried cables is also very easy to damage the cables in operation. Sometimes if the damage is not serious, it will take several months or even years to cause the damage site to completely break down and form a fault, and sometimes the damage is serious and a short circuit fault may occur, which directly affects the safety production of the electricity unit and the electricity unit.

2. The insulation is damp. This is also very common and usually occurs at cable joints that are buried directly or in a pipe run. For example, the unqualified production of cable joints and the making of joints under humid climatic conditions will cause water or water vapor into the joints, and water branches will be formed under the action of the electric field for a long time, which will gradually damage the insulation strength of the cable and cause failure.

3. Chemical corrosion. The cable is directly buried in the area with acid and alkali effect, which often causes the armor, lead skin or outer sheath of the cable to be corroded, and the protective layer is subjected to long-term chemical corrosion or electrolytic corrosion, resulting in the failure of the protective layer and the reduction of insulation, which will also lead to cable failure. Chemical: The corrosion of the cable of the unit is quite serious.

4. Long-term overload operation. Overload operation, due to the thermal effect of the current, the load current through the cable will inevitably lead to conductor heating, at the same time, the skin effect of the charge, the eddy current loss of the steel armor, the loss of the insulating medium will also produce additional heat, so that the temperature of the cable increases. In long-term overload operation, excessive temperature will accelerate the aging of the insulation and cause the insulation to break down. Especially in the hot summer, the temperature rise of the cable often leads to the weak part of the cable insulation being broken down first, so in the summer, the cable fault is particularly numerous.

5. Cable gland failure. Cable joints are the weakest link in cable routes, and cable gland failures caused by direct human negligence (poor construction) often occur. In the process of making cable joints, if the original mesh is not crimped tightly and the heating is not sufficient, it will lead to the reduction of the insulation of the cable head, which will cause accidents.

6. Environment and temperature. The external environment and heat source of the cable will also cause the cable temperature to be too high, insulation breakdown, and even explosion and fire.

7. Normal aging of the cable body or natural disasters and other reasons.
Rittal Cables – What are the causes of faults in wires and cables?

More on that
How to set the temperature of the Rittal air conditioner How to set the temperature of the Rittal air conditioner

1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters. 2. High temperature alarm: ...

Some precautions should be taken in the installation and setting of Rittal air conditioning Some precautions should be taken in the installation and setting of Rittal air conditioning

The arrangement of the electronics in the cabinet Note: Condensation is dangerous! When the electronics are arranged in a Rittal cabinet, the cold air from the air conditioner must not flow directly to the live device. Cold air must not be allowed to flow directly to a hot exhaust gas stream from a live device such as a frequency converter. Because this will lead to ...

What are the common cable management methods for Rittal cabinets – network cabinets? What are the common cable management methods for Rittal cabinets – network cabinets?

1. The network cabinet distribution frame is fixed in place, the panel paper is loaded into the distribution frame on the front, and the tray is installed on the back. 2. Positioning of the cable management board, the direction of the cable management board should be determined before threading when positioning the cable management board, so that the cable management board does not need to twist the direction in the process of line management, and it can enter the ...

Rittal Cables – precautions for the installation and wiring of control cables Rittal Cables – precautions for the installation and wiring of control cables

Precautions for the installation and wiring of control cables: 1. Under the eaves. Cables can only be used if they are not directly exposed to sunlight or ultra-high temperatures, and it is recommended to use pipes. Ultraviolet (UV) – Do not apply cables without UV protection to direct sunlight rings ...

Rittal cables – type descriptions for power cables Rittal cables – type descriptions for power cables

The model of the power cable 1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...

Rittal cabinets – what are the technical requirements for the cabinets? Rittal cabinets – what are the technical requirements for the cabinets?

1. It should have good technical performance. The structure of the cabinet should be designed according to the electrical and mechanical properties of the equipment and the requirements of the use environment, so as to ensure that the structure of the cabinet has good stiffness and strength, as well as good electromagnetic isolation, grounding, noise isolation, ...

Rittal RBT side-mounted cooling unit cabinet air conditioning Rittal RBT side-mounted cooling unit cabinet air conditioning

Rittal RBT cooling units – the most economical option for you! If a limited budget makes you extremely cost-conscious, then RBT is the choice for your ambition. After large-scale assembly line production, as well as the excellent functions of the cooling unit itself, the RBT has achieved a very high ...

Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk" Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk"

The Age of Discovery, which began at the end of the 15th century, linked the world and was one of the most important historical steps in the process of human civilization. In the 21st century, in the development trend of global interconnection and China's intelligent manufacturing, the shipbuilding industry has ushered in high-energy development prospects.   Smart ships, low...

Rittal innovates smart services to help build new infrastructure in the 5G era Rittal innovates smart services to help build new infrastructure in the 5G era

The construction of new infrastructure (new infrastructure) is a change in the upgrading and transformation of the industrial structure. As an important part of the new infrastructure, the data center provides a solid and extensive infrastructure guarantee for 5G, artificial intelligence, Internet of Things and other occupations. Rittal brings a new generation of infrastructure solutions ...

Rittal & Lithium Battery The industrial transformation of the trillion-dollar new energy vehicle market Rittal & Lithium Battery The industrial transformation of the trillion-dollar new energy vehicle market

The power of the 10 billion market   With the help of continuous favorable policies, China's new energy vehicles have maintained rapid growth this year. According to data from the China Association of Automobile Manufacturers, the production and sales of new energy vehicles reached a new high in October, with a year-on-year increase of 87.6% and 81.7% to 762,000 and 714,000 units, respectively.

Rittal Cables – what are the ways to lay wires and cables? Rittal Cables – what are the ways to lay wires and cables?

1. Buried laying The laying method of laying the cable immediately underground is called buried laying. The buried cable must be armored cable and anti-corrosion coating protection cable, and the bare cable cannot be buried. Generally, the depth of the cable trench shall not exceed 0.9m, and the buried laying shall be paved ...

Rittal fans – analysis of the reasons why cooling fans do not rotate Rittal fans – analysis of the reasons why cooling fans do not rotate

1. Power failure: The power supply of the fan fails, such as the power cord is disconnected, the power plug is loose, etc., which will cause the current to fail to transmit normally, resulting in the fan stopping and rotating. 2. The temperature is too low: Some heat dissipation windbreakers have a temperature protection function, when the temperature is too low, the fan will automatically ...

Rittal Temperature Control Portfolio – for new energy applications Rittal Temperature Control Portfolio – for new energy applications

With the continuous promotion of the dual carbon policy, the development of new clean energy such as wind power has been making great progress. China and United States are among the world's largest growing countries for wind energy equipment. Wind turbines typically need to operate reliably for more than 20 years to deliver electricity to people. To this end ...

Rittal cables – the performance difference of control cables Rittal cables – the performance difference of control cables

The control cable has the characteristics of moisture-proof, anti-corrosion and anti-damage, and can be laid in tunnels or cable trenches. Power cables are used to transmit and distribute high-power electric energy in the main line of the power system, and the control cable transmits the electric energy directly from the distribution point of the power system to the power supply of various electrical equipment and appliances.

Rittal Cables – an introduction to the performance of industrial control cables Rittal Cables – an introduction to the performance of industrial control cables

Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of cables for power transmission at working temperatures, current carrying capacity, short circuit and overload capabilities, the thermal deformation and thermal impulse resistance of the constituent materials.

Alarm code analysis for Rittal chillers Alarm code analysis for Rittal chillers

1. E1: Temperature sensor failure 2. E2: Humidity sensor malfunction 3. E3: Compressor overload protection 4. E4: Compressor phase loss protection 5. E5: Compressor short circuit protection 6. E6: Compressor switch failure 7. E7: Fan failure ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Which electrical equipment must be grounded or zeroed? Answer: (1) The base and shell of generators, transformers, motors, high and low voltage electrical appliances and lighting appliances; (2) the secondary coil of the transformer; (3) the framework of the switchboard and the control panel; (4) Transmission device of electric equipment ...

An introduction to the features of Rittal cabinet fans An introduction to the features of Rittal cabinet fans

Wide air volume range: 20-900m3/h Innovative diagonal flow fan and brushless DC EC motor technology for higher air flow and uniform distribution of cold air Comes with an interface module for controlling and monitoring fans The standard degree of protection is IP54, up to IP56 with a water spray cover ...

Here's a quick overview of what products Rittal makes Here's a quick overview of what products Rittal makes

Many customers don't know what products Rittal makes, so today I will simply classify Rittal products. Rittal products are mainly divided into 6 categories below 6 (1) Rittal control cabinet: small cabinet (here can also be subdivided polycarbonate cabinet PK, junction box KL, compact control box EB, ...

Presentation of the features of the Rittal cabinet TS8 seismic kit Presentation of the features of the Rittal cabinet TS8 seismic kit

Since ancient times, truss planning has been the way to create a stable and earthquake-tolerant mechanical structure. This plan consists of individual members connected at two ends, which form a triangle. The members are almost exclusively subjected to compressive or tensile forces, which makes the entire structure very strong.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top