Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

Which electrical equipment must be grounded or zeroed?

Answer: (1) The base and shell of generators, transformers, motors, high and low voltage electrical appliances and lighting appliances; (2) the secondary coil of the transformer; (3) the framework of the switchboard and the control panel; (4) Transmission device of electric equipment; (5) Metal structure, concrete frame and metal fence of power distribution devices inside and outside the house; (6) Cable head and cable box shell, cable sheath and threading steel pipe; (7) The tower of the power line and the switchgear and capacitors installed on the pole of the distribution line.

  What data is on the nameplate of the asynchronous motor? What does each mean?

Answer: The following data is mainly marked on the nameplate of AC asynchronous motor, and its significance is explained as follows:

(1) Rated power (P): It is the output power on the shaft of the motor.

(2) Rated voltage: refers to the voltage of the line added on the winding.

(3) Rated current: stator winding line current.

(4) Rated speed (r/min): the number of revolutions under the rated load.

(5) Temperature rise: refers to the insulation level that exceeds the ambient temperature.

(6) Working quota: that is, the allowable working operation mode of the motor.

(7) Winding connection: Δ or Y connection, corresponding to the rated voltage.
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

More on that
Rittal cabinets - judgment and handling of common faults in high-voltage switchgear Rittal cabinets - judgment and handling of common faults in high-voltage switchgear

1. Judgment and treatment of sudden tripping fault of high-voltage switchgear during operation 1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature. 2) Judgment method: judging the cause of the fault can be based on the relay off, remote ...

Rittal Rittal economy air conditioning, RBT cooling unit Rittal Rittal economy air conditioning, RBT cooling unit

Rittal has an economical air conditioner on the market, and the Rittal RBT cooling unit – is your most economical choice! If a limited budget makes you more interested in the cost Extremely sensitive, then RBT is the ideal choice for you Choose. Produced through large-scale assembly lines, as well as cold But the unit itself is excellent ...

Common faults and solutions for Rittal cabinet air conditioners Common faults and solutions for Rittal cabinet air conditioners

If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start; Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high. The voltage of the air conditioner is unstable, and the compressor cannot be started normally.

Rittal cables – the basic structure of industrial control cables Rittal cables – the basic structure of industrial control cables

1. Conductor It is the main component of the product to play its use function, and it is to transmit electricity or information, that is, to transmit electric current or electromagnetic waves on the conductor. The conductor is the basic and indispensable main component of the product for the transmission of electric current or electromagnetic wave information. 2. Insulation ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the types of electric shocks? Answer: Direct electric shock, indirect contact electric shock, induced voltage electric shock, lightning electric shock, electrostatic electric shock. What are the organizational measures to ensure safety when working on electrical equipment? Answer: work ticket system, operation ticket system, inventory site and comprehensive ...

Rittal cabinets – maintenance methods for low-voltage distribution cabinets Rittal cabinets – maintenance methods for low-voltage distribution cabinets

1. The purpose is to ensure the normal and safe operation of the low-voltage distribution cabinet and the control cabinet of each equipment. Second, the scope is suitable for the low-voltage distribution room distribution cabinet, and the control cabinet of each equipment shall be implemented with reference to the relevant provisions according to the specific situation. Third, the responsibility of the mechanical and electrical installation and maintenance engineering department maintenance team every six months ...

Rittal Cables – precautions for the installation and wiring of control cables Rittal Cables – precautions for the installation and wiring of control cables

Precautions for the installation and wiring of control cables: 1. Under the eaves. Cables can only be used if they are not directly exposed to sunlight or ultra-high temperatures, and it is recommended to use pipes. Ultraviolet (UV) – Do not apply cables without UV protection to direct sunlight rings ...

Rittal and the Fraunhofer Institute in Germany explain the implementation of the digital twin Rittal and the Fraunhofer Institute in Germany explain the implementation of the digital twin

How to promote the further development of smart factories and smart production? The Rittal Hager plant in Germany illustrates how the smart factory can be accelerated with a digital twin in manufacturing!   As one of the world's modern cabinet production bases, the Hager plant has a production capacity of 24,000 square meters.

Some advantages of the Rittal compact AE enclosure Some advantages of the Rittal compact AE enclosure

The Rittal compact AE cabinet with its new internal expansion rails –Supplementary internal expansion for machining – Can be done in a time-saving manner in the side, bottom and top cover areas Installation – Two rows of adjustable TS 8 system holes for installation capacity Outer space...

Rittal X Kongsberg | Smart ship "Wei" can be expected Rittal X Kongsberg | Smart ship "Wei" can be expected

Smart ships are a key area clearly supported by national policies. Driven by policy guidance and innovation, China has achieved phased results in the research and construction of smart ships. As the world's leading provider of enclosure systems, Rittal has a wide range of applications in the marine and port sectors.

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the main technical parameters of the fuse? Answer: A. Rated voltage, B. Rated current, C. Breaking capacity, D. Melting characteristics, E. Overvoltage. What are the main products of low-voltage power distribution equipment? Answer: Low-voltage distribution panels, switch cabinets, switch boards, lighting boxes, power boxes and electrical ...

Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets

What is a substation? A: It is a power supply hub that receives electrical energy from the power system, transforms (boosts or downgrades), and then distributes the power. What is the main role of transformers in the power system? Answer: The main function is to convert the voltage to facilitate ...

Here's a quick overview of what products Rittal makes Here's a quick overview of what products Rittal makes

Many customers don't know what products Rittal makes, so today I will simply classify Rittal products. Rittal products are mainly divided into 6 categories below 6 (1) Rittal control cabinet: small cabinet (here can also be subdivided polycarbonate cabinet PK, junction box KL, compact control box EB, ...

Analysis of the interior of the Rittal cabinet TS8 series Analysis of the interior of the Rittal cabinet TS8 series

RITTAL TS8 cabinet front door door rear sealing plate, a galvanized mounting plate 16-fold profile ISV-TS 8 cabinets with a maximum current of 1600 A single door Can be installed in all TS 8 cabinets of the same height and depth - Can be pre-installed in configurations - Available in the spirit ...

What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure? What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure?

1. Safety: As the carrier of electrical equipment, the outdoor cabinet must have excellent structural design, solid materials, and firm bottom fixation to meet the requirements of strong typhoons, strong rainstorms, and even strong earthquakes. At the same time, the cabinet should have anti-leakage, anti-short circuit, anti-cut and other requirements. 2. Rainproof and dustproof ...

Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring

1. Site selection. The location of the low-voltage distribution room should be close to the load center, set up in a place with less dust, less corrosive medium, dry and slight vibration, and should appropriately leave room for development; Second, the layout of power distribution equipment. The layout of the distribution equipment in the low-voltage distribution room must follow the principle of safety, safety, and safety.

Rittal cabinets – installation steps and rules for cabinet placement Rittal cabinets – installation steps and rules for cabinet placement

Cabinet installation steps: 1. Before installing the cabinet, check whether the exhaust device of the cabinet is stable, whether the number of equipment support plates is complete, and whether the pulleys and support columns are stable. 2. The model, specification and device orientation of the cabinet should meet the planning requirements. 3. Cabinet ...

Rittal Cables – What do you need to pay attention to when wiring industrial control cables? Rittal Cables – What do you need to pay attention to when wiring industrial control cables?

1. The weight of the cable in the industrial control cable drag chain should be evenly distributed, so as to avoid accidents caused by uneven weight during operation, and the principle of distributing the cable is that the heavier one is located on both sides and the lighter one is located in the middle. All industrial control cables must be securely fastened to one end of the energy chain, so that ...

Rittal Cables – the scope of application for wires and cables Rittal Cables – the scope of application for wires and cables

Power system The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables, which are basically replaced by plastic power cables), rubber sheathed cables, overhead insulated cables, branch cables (replacing part of the busbars), ...

Common fault codes and handling methods for Rittal cabinet air conditioners Common fault codes and handling methods for Rittal cabinet air conditioners

1. E0: Indoor temperature sensor is faulty. When this fault code appears, you need to check whether the indoor temperature sensor is working properly. 2. E1: Outdoor temperature sensor failure. When this fault code appears, you need to check whether the outdoor temperature sensor is working properly. 3. E2 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top