Rittal Cables – an introduction to the performance of industrial control cables

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of power transmission cables, current carrying capacity, short circuit and overload ability, the thermal deformation and thermal shock resistance of the constituent materials, the thermal expansion of the materials, and the dripping function of impregnating or coated materials.

Mechanical function: The production process of industrial control cables includes many technological processes, among which the conductor needs to be stretched and formed through a mold. The mechanical function of industrial control cable refers to its tensile strength, elongation, bending, elasticity, flexibility, sensational resistance, wear resistance and mechanical impact resistance.

Electrical function: The function of most industrial control cables is the transmission of current, so conduction is a necessary function, but in order to avoid wrong conduction, an insulating material is also required.

Aging function: We humans are afraid of getting old, and industrial control cables will also age and oxidize. The aging function of industrial control cable refers to the ability of industrial control cable and its composition to adhere to its original function under the effect of mechanical stress, electrical stress, thermal stress and other external factors, or under the effect of external climatic conditions.

Corrosion resistance and weather resistance: Industrial control cables need to have a certain resistance to the surrounding environment due to the different areas and environments in which they are used. Corrosion resistance and weather resistance refer to resistance to electrochemical corrosion, biological and bacterial corrosion, chemical (oil, acid, alkali, chemical solvents, etc.), salt spray resistance, light resistance, cold resistance, mildew resistance, and moisture resistance.
Rittal Cables – an introduction to the performance of industrial control cables

More on that
Air conditioner shows H1 fault code solution – Rittal Air conditioner shows H1 fault code solution – Rittal

1. The air conditioner displays the H1 fault code - the reason When the outdoor temperature is low and the humidity is high, the heat exchanger of the outdoor unit will be frosted after the air conditioner runs for a period of time, then the automatic defrost function will be activated, and the heating operation will be temporarily stopped for 5-10 minutes. Air conditioner heating defrost shows H1 which is normal ...

What are the application areas of Rittal cabinets – cabinet air conditioners? What are the application areas of Rittal cabinets – cabinet air conditioners?

Indoor unit: suitable for all kinds of control boxes, distribution boxes and electrical cabinets in machinery, electric power, chemical industry, textile machinery, automation equipment, instrumentation and other industries with high requirements for temperature and humidity. It can also be used to regulate temperature and humidity in small spaces. Outdoor unit: suitable for outdoor general base station, outdoor ...

Rittal cabinets – the characteristics of GDD and GCK low-voltage distribution cabinets Rittal cabinets – the characteristics of GDD and GCK low-voltage distribution cabinets

1. GGD AC low-voltage distribution cabinet has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, seriality, strong practicability, novel structure and high protection level. It can be used as a replacement product for low-voltage switchgear. Structural features ...

Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets

What is a substation? A: It is a power supply hub that receives electrical energy from the power system, transforms (boosts or downgrades), and then distributes the power. What is the main role of transformers in the power system? Answer: The main function is to convert the voltage to facilitate ...

Rittal cabinets – how network cabinets are organized and maintained Rittal cabinets – how network cabinets are organized and maintained

1. Preparation First of all, the user should be notified to organize the cabinet without affecting the normal operation of the user. Then, according to the topology of the network, the existing equipment, the number of users, the user group and other factors, the wiring diagram and equipment inside the cabinet are outlined.

Rittal's enclosure – seven common faults in the distribution cabinet and their failure analysis Rittal's enclosure – seven common faults in the distribution cabinet and their failure analysis

1. The circuit breaker cannot be closed Causes: 1. The undervoltage coil does not work (the voltage is normal). Solution: Replace the undervoltage coil. 2. Press the closing button, and the closing coil will not work when it is powered up. Solution: Replace the undervoltage coil. 3. Cooperation...

Rittal cables – the basic structure of power cables Rittal cables – the basic structure of power cables

1. Core: The core is the conductive part of the power cable, which is used to transmit electric energy and is the main part of the power cable. 2. Insulation layer: The insulation layer is to electrically isolate the core from the ground and the cores of different phases to ensure the transmission of electric energy.

Rittal Cables – the operation of power cable routes Rittal Cables – the operation of power cable routes

The operating voltage of the cable Generally speaking, there is a certain relationship between the operating voltage of the cable and the rated voltage. If some cable lines are not in use, they must be connected to the power grid to ensure that the cable lines are not exposed to moisture. When the neutral point is not grounded ...

Rittal cabinets – an introduction to the installation steps and features of the control cabinet Rittal cabinets – an introduction to the installation steps and features of the control cabinet

The control cabinet is according to the requirements of electrical wiring to assemble switchgear, measuring appearance, maintenance appliances and auxiliary equipment in a closed or semi-closed metal cabinet or screen panel, and its arrangement should meet the requirements of the normal operation of the power system, easy to overhaul, and not to endanger the safety of people and surrounding equipment. Normal operation ...

Rittal enclosures – the details that need to be taken into account for the daily care and maintenance of your enclosures Rittal enclosures – the details that need to be taken into account for the daily care and maintenance of your enclosures

1. Avoid light The server is required to operate in a constant temperature environment, and direct sunlight will increase the temperature in the computer room, which will damage the display and shorten its service life. When operating in IDC and ISP data centers, it is impossible to see a ray of sunshine. So, in ...

Rittal cables – the difference between power cables and control cables Rittal cables – the difference between power cables and control cables

The power cable is used to transmit and distribute large-scale electrical energy in the main line of the power system, and the control cable directly transmits the electric energy from the distribution point of the power system to the power connection line of various electrical equipment and appliances. The rated voltage of power cables is generally 0.6/1KV and above, and the control cables are mainly 4 ...

Causes and solutions of low-voltage distribution cabinet alarms Causes and solutions of low-voltage distribution cabinet alarms

1. It is not displayed at that time. Solution: Check whether the sample signal cable is not connected. 2. Whether the fuse core of the controller in the cabinet is burned out. Solution: Remove the burned out fuse core and replace it with a new one. 3. The voltage of the distribution cabinet is too high, and the overvoltage alarm. Workaround: Re...

Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring

1. Site selection. The location of the low-voltage distribution room should be close to the load center, set up in a place with less dust, less corrosive medium, dry and slight vibration, and should appropriately leave room for development; Second, the layout of power distribution equipment. The layout of the distribution equipment in the low-voltage distribution room must follow the principle of safety, safety, and safety.

Rittal cabinets – precautions for high and low voltage distribution cabinets Rittal cabinets – precautions for high and low voltage distribution cabinets

1. The elevation or verticality of the distribution box (panel) exceeds the allowable deviation: it is caused by inaccurate measurement and positioning or uneven ground, and should be corrected in time. 2. The iron frame of the distribution box is not square: the iron frame is not straightened and aligned before the installation of the iron frame, or the position of the fixed point is deviated during installation.

Rittal presents its modular data centre solutions Rittal presents its modular data centre solutions

Now AI has been widely used in many fields, and while we enjoy the convenience brought by AI skills, we should also know that behind these AI skills are a huge amount of data processing and communication by weak servers, and then find the most efficient solutions.

Rittal cables – type descriptions for power cables Rittal cables – type descriptions for power cables

The model of the power cable 1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...

How to deal with the A02 fault reported by Rittal air conditioner How to deal with the A02 fault reported by Rittal air conditioner

1. Check whether the filter screen of the Rittal air conditioner is blocked, if it is blocked, clean the lower filter in time. 2. Check whether there is any remaining freon in Rittal air conditioner, and if not, inform the professional maintenance personnel of the air conditioner to add fluoride in time. 3. Check the function of Rittal air conditioner.

Rittal continues to develop a new family of intelligent power distribution systems Rittal continues to develop a new family of intelligent power distribution systems

Rittal Riline Compact is a proven solution for compact power distribution systems for enclosures and small control cabinets, which is used in plant control systems in industries such as automotive, rubber, packaging machinery and renewable energies. All along, RiLin...

Rittal cabinets - judgment and handling of common faults in high-voltage switchgear Rittal cabinets - judgment and handling of common faults in high-voltage switchgear

1. Judgment and treatment of sudden tripping fault of high-voltage switchgear during operation 1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature. 2) Judgment method: judging the cause of the fault can be based on the relay off, remote ...

Rittal cables – the common code for cables Rittal cables – the common code for cables

Usage code - not marked as power cable, K- (control cable), P- (signal cable); Conductor material code - not marked as copper (can also be marked as CU), L- (aluminum); Inner Sheath Code – Q-(Lead Packed), L- (Aluminum Cladding), H- (Rubber Jacket), V-(Polyvinyl Chloride ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top