If a humidity sensor is used at different temperatures, the effect of temperature drift should also be taken into account in the indication value. As we all know, relative humidity is a function of temperature, and temperature has a significant impact on the relative humidity in a given space.
Precautions for the selection of humidity sensors
(1) Select and measure the scale
As with weight and temperature, the first step in selecting a humidity sensor is to confirm the measurement scale. In addition to climate and scientific research departments, temperature and humidity measurement and control generally do not require full humidity (0-100%RH) measurement.
(2) Select and measure accuracy
Measurement accuracy is the most important goal of humidity sensors, and every one percentage point of progress is a step up or even a grade for humidity sensors. Due to the different levels of accuracy to be achieved, the manufacturing cost varies greatly and the selling price varies greatly. Therefore, the user must be tailor-made, and should not blindly pursue high, refined and sharp.
If a humidity sensor is used at different temperatures, the effect of temperature drift should also be taken into account in the indication value. As we all know, relative humidity is a function of temperature, and temperature has a significant impact on the relative humidity in a given space. Every 0.1°C change in temperature. A humidity change of 0.5%RH (error) will occur. If it is difficult to achieve a constant temperature in the application case, it is not appropriate to propose too high humidity measurement accuracy.
In most cases, if there is no accurate temperature control method, perhaps the measured space is unsealed, and the accuracy of 5%RH is sufficient. For some spaces that require accurate control of constant temperature and humidity, it may be necessary to keep an eye on the humidity changes at any time, and then choose a humidity sensor with an accuracy of more than 3%RH.
The requirement for an accuracy higher than 2%RH is difficult to achieve even with a standard humidity generator for calibrating the sensor, let alone the sensor itself. Even at 20-25°C, it is difficult to achieve an accuracy of 2%RH. Usually the characteristics given in the product literature are measured at room temperature (20°C, 10°C) and in a clean gas.
|
More on that
|
Pre-selection of sensors
In the early application and selection of sensors, how to choose is a very important point, and the selection is smooth, and the following will briefly talk about how the sensor is selected in the early stage.
The use of the sensor in practical operation is relatively common and may be practical ...
|
|
We offer a wide range of barriers for different needs
We offer a wide range of barriers for different requirements. Barrier and Zener barriers are available to ensure the safe transmission of signals in hazardous areas.
Barrier barriers
In addition to the explosion-proof function, the barrier ...
|
|
How to distinguish between good and bad angle sensors
The use of angle sensors in practical manipulation is relatively common, and may be useful for the needs of different occupations and different fields. No matter how good the instrument is, there is a quality of the instrument itself, and in order to reduce the presentation of errors in the measurement process, users need to choose a good quality ...
|
|
The F99 series inclination sensor helps "China speed"
During the epidemic, Huoshenshan Hospital, which rose from the ground within 10 days, made foreign netizens exclaim miracles. This is a life-and-death contest against the epidemic, and it is also a speed that Chinese are proud of. Behind the "China speed", advanced construction equipment is indispensable, in which the project ...
|
|
Single receiver and multiple receiver for photoelectric sensors
Photoelectric sensors are generally composed of three parts: transmitter, receiver and detection circuit, and its operating principle is to first convert the measured change into the change of the optical signal, and then convert the change of the optical signal into the change of the electrical signal (this part is called the "photoelectric effect"). According to the detection method, it is not ...
|
|
We participate in discussions on Industry 4.0 in Germany
As one of the early participants and drafters of Industry 4.0z in Germany, we were involved in the discussion of the RAMI reference architecture model. Focusing on connectivity and data presentation, through exhibitions and market applications, we have achieved relevant results, collected effective feedback, and guided our digital and physical products.
|
|
Introducing the Sofis Valve Position Indicator
Sofis, an expert in the operation of valves in the process industry, relies on sensors for its latest treatment solution, the "Valve Orientation Indicator" (VPI). VPI provides an overview of the orientation of manual valves in the plant network. Combined with integrated sensors and automatic detection...
|
|
Commonly used sensor type – Doublebless
1. Semiconductor type Semiconductor gas sensor is a gas sensor that uses semiconductor gas sensing elements as sensitive elements, which is the most common gas sensor, widely used in combustible gas leakage detection equipment in homes and factories, and is suitable for the detection of methane, natural gas, liquefied gas, hydrogen, etc.
|
|
Sensor calibration method – Blessing Blessing
Sensor calibration refers to the process of transmitting the standard value expressed by the norm to the indexing of the sensor's operating range, and the indexing is determined.
The calibration of the sensor is based on the standard value generated by a standard device (e.g. a known standard force, pressure, torque, displacement, etc.).
|
|
The FDH-1 simplifies bus installation
1. Mastery: Take control of your bus
The handheld bus diagnostic device FDH-1 can be regarded as an increasingly intelligent multimeter. It only needs to press a button to quickly view any network segment. And it can work independently, which is a good addition to the engineer's stuff box.
...
|
|
Q&A on ultrasonic sensor technology
Q1: How does the ultrasonic sensor work?
Ultrasonic sensors are used to measure the detection function of emitting high-frequency sound pulses that are inaudible to the human ear, which are dispersed in the air into a conical shape and reflected back as soon as they hit an object. Ultrasonic ...
|
|
Selection criteria for proximity switches
Points to note in the selection of proximity switches
1. The working voltage of the proximity switch output is selected, generally DC type DC24V or AC AC250V optional;
2. Proximity switch output method selection, generally NPN-normally open, NPN-...
|
|
Classification and working methods of photoelectric sensors – we are blessed
1. Slotted photoelectric sensor
A light transmitter and a receiver are mounted face to face on either side of a slot is a fork photoelectric. The luminaire announces infrared or visible light, and the light receiver receives the light unobstructed. But when the object to be detected passes through the trough, the light is blocked ...
|
|
Pressure sensors are prone to malfunction – we are blessed
The first is pressure, and the transmitter can't afford to lose it. In this case, see if the pressure connector is leaking or clogged, if you admit that it is not, look at the wiring method and see if the power supply is normal, simple pressure to confirm if the output has changed, or if there is an output at the zero point of the sensor ...
|
|
Features and functions of photoelectric switches of the sensor
Photoelectric switches are what we generally call sensors. The national standard GB7665-87 defines the definition of the sensor: a device or device that can sense the measured part of the rule and convert it into a usable signal according to the certain rules, which is generally composed of a sensitive element and a conversion element.
...
|
|
Selection of proximity sensor sensors
1. Select the type of proximity switch according to the detected object. If the detection object is a metal *** inductive proximity switch, if the detected object is a non-metal such as wood, plastic, paper, water, etc. or a smaller and thinner metal, a capacitive proximity switch should be selected.
...
|
|
P+F WIS wireless sensing system for wireless transmission
In the field of industrial automation, there is always the challenge of connecting the individual sensor components on movable machine components. Regardless of their mechanical structure, the use of e-chains® or slip rings tends to wear or crack slightly. As a result, their durability is limited, and together they cause ...
|
|
Wiring of weighing strain gauge tension and compression sensors – we are in control
Wiring method of weighing strain tension and compression sensor:
Strain gauge tension and compression load cells can be wired in two different input and output wiring methods:
The first is the four-wire connection method.
The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very convenient to use.
|
|
Wireless HART technology for industrial processes
WirelessHART uses the 2.4 GHz band (which is no-nonsense and globally) as a transmission medium for a variety of radio skills, including WLAN, Bluetooth, and ZigBee. However, WirelessHART is more than just a variant of WLAN.
...
|
|
A common type of sensor – a sensor
Resistive
A resistive sensor is a device that converts physical quantities such as displacement, deformation, force, acceleration, humidity, temperature, etc. into resistance values. There are mainly resistive strain gauge, piezoresistive, thermal resistance, thermal, gas-sensitive, moisture-sensitive and other resistive sensor materials.
|
|