Classification and working methods of photoelectric sensors – we are blessed

Create Date: 2024-8-30 12:03:23|Source: P+F/Double Blessing

1. Slotted photoelectric sensor

A light transmitter and a receiver are mounted face to face on either side of a slot is a fork photoelectric. The luminaire announces infrared or visible light, and the light receiver receives the light unobstructed. However, when the detected object passes through the trough, the light is blocked, and the photoelectric switch is activated. Output a switch control signal to block or turn on the load current, and then complete a control action. The detection interval of the slot switch is generally only a few centimeters because it is limited by the overall structure.

                               Classification and working methods of photoelectric sensors – we are blessed

2. Thru-beam photoelectric sensor

By separating the luminaire from the receiver, the detection interval can be increased. The photoelectric switch composed of a light emitter and a light receiver is called a through-beam split photoelectric switch, referred to as a through-beam photoelectric switch. Its detection interval can be several meters or even tens of meters. When using, the luminaire and the receiver are installed separately on both sides of the path of the detector, and the detector blocks the optical path during the passage, and the receiver outputs a switch control signal on the action.

3. Reflector type photoelectric switch

The reflector and the receiver are installed in the same device, a reflector is installed in front of it, and the photoelectric control function is completed by using the reflection principle, which is called the reflector reflection (or mirror reflection type) photoelectric switch. Under normal conditions, the light announced by the luminaire is reflected back by the reflector and received by the receiver; Once the optical path is blocked by the detector and the receiver cannot receive light, the photoelectric switch will act and output a switch control signal.

4. Diffusion reflection photoelectric switch

It also has a light emitter and a light collector in the detection head, but there is no reflector on the front. Under normal conditions, the luminaire announces that the light receiver cannot be found. When the detected object blocks the light and partially reflects the light back, the receiver receives the light signal and outputs a switching signal.

More on that
Installation and maintenance of the FDH-1 bus facility Installation and maintenance of the FDH-1 bus facility

A smooth production process is the policy that every production manager strives to achieve. In order to accomplish this policy, a high-performance automation system is required. With the new FDH-1 handheld bus diagnostic device, you will be on your way to maximizing the availability of your equipment.

Wiring of weighing strain gauge tension and compression sensors – we are in control Wiring of weighing strain gauge tension and compression sensors – we are in control

Wiring method of weighing strain tension and compression sensor: Strain gauge tension and compression load cells can be wired in two different input and output wiring methods: The first is the four-wire connection method. The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very convenient to use.

We participate in discussions on Industry 4.0 in Germany We participate in discussions on Industry 4.0 in Germany

As one of the early participants and drafters of Industry 4.0z in Germany, we were involved in the discussion of the RAMI reference architecture model. Focusing on connectivity and data presentation, through exhibitions and market applications, we have achieved relevant results, collected effective feedback, and guided our digital and physical products.

Troubleshooting for coding problems Troubleshooting for coding problems

P+F encoders are devices that compile signals (e.g. bit streams) or data and convert them into signals that can be communicated, transmitted, and stored. The P+F encoder converts angular or linear displacements, the former known as the code disc and the latter into an electrical signal. Therefore, the phenomenon: 1, ...

Introduction to the sensor model Introduction to the sensor model

Proximity Switches: NBB2-12GM50-E2 NBB2-12GM50-E0 NBN4-12GM50-E2 NBN4-12GM50-E0 NBB5-18GM50-E2 NBB5-18GM50-E0 NBN8-18GM50-E2 NBN8-18GM50-E0 NBN15-30GM50-E0 NBN15-3 ...

We made a wonderful appearance at SIAF 2022 We made a wonderful appearance at SIAF 2022

The 2022 Guangzhou World Industrial Automation Skills and Equipment Exhibition (SIAF) landed at the China Import and Export Fair Complex on March 3, kicking off the prelude to this year's industrial automation career exhibition. As the driver and innovator of Industry 4.0, we continue to provide customers with the future of the future.

Anti-corrosion method of pressure sensors Anti-corrosion method of pressure sensors

Pressure sensors are used in all walks of life, especially in the industry, many pressure sensors, but the industry generally requires pressure sensors to be able to prevent corrosion, pressure sensor joints and cavities are imported stainless steel for all processing, as the pressure transmitter projectile body of stainless steel material resistance...

Eltra Incremental Rotary Encoder Types Eltra Incremental Rotary Encoder Types

Eltra incremental encoders fall into three categories: Optical solid shaft incremental encoder Eltra. The couplings in these types are made of solid shafts. · EL-ER 30 E/H; · EH 38 A/B/D; · EL-E ...

Single receiver and multiple receiver for photoelectric sensors Single receiver and multiple receiver for photoelectric sensors

Photoelectric sensors are generally composed of three parts: transmitter, receiver and detection circuit, and its operating principle is to first convert the measured change into the change of the optical signal, and then convert the change of the optical signal into the change of the electrical signal (this part is called the "photoelectric effect"). According to the detection method, it is not ...

A little bit about photoelectric sensors – a blessing A little bit about photoelectric sensors – a blessing

Under normal circumstances, a photoelectric sensor consists of two parts: a processing path and a processing element. Its basic principle is to use the photoelectric effect to convert the measured change into a change in the optical signal, and then use the optoelectronic components to further convert the non-electrical signal into an electrical signal. The "photoelectric effect" refers to the use of light ...

Accelerometer sensitivity deviation – a blessing Accelerometer sensitivity deviation – a blessing

An accelerometer is an electronic device that measures the force of acceleration and converts it into a signal. It is possible to calculate the skew angle of the device relative to the horizontal plane, and analyze the equipment movement method through the analysis of dynamic acceleration. The requirements for sensitivity are very high, in fact, no matter what type ...

Precautions for the installation of linear displacement sensors – we are blessed Precautions for the installation of linear displacement sensors – we are blessed

1. The linear displacement sensor should be used to prevent over-travel in the application, and a certain margin should be left in the selection to facilitate the use of the device. 2. The linear displacement sensor device is fixed by a bracket, and then the follow-up shaft is connected to the moving object to be measured. When the sensor is fixed in the device, it can be ...

Vibratory load cell performance – we are blessed Vibratory load cell performance – we are blessed

Vibrating load cell: When an elastic element is subjected to a force, its natural vibration frequency is proportional to the square root of the force. By measuring the change in the natural frequency, the force of the analyte acting on the elastic element can be calculated, and then its mass can be found. There are two types of vibrating sensors: vibrating wire type and tuning fork type. ...

A brief introduction to our sensors A brief introduction to our sensors

Proximity sensors are a general term for sensors that replace contact detection methods such as limit switches and do not require contact detection of the detected object. It is capable of converting information about the motion and presence of objects into electrical signals. The detection method of replacing the electrical signal includes: using an electromagnetic induction bow to ...

Wiring of weighing strain gauge tension and compression sensors – we are in control Wiring of weighing strain gauge tension and compression sensors – we are in control

Strain gauge tension and compression load cells are available in two different input and output wiring methods: The first is the four-wire connection method. The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very convenient to use, but when the cable is long, it is easy to be shaken by the operating temperature.

Introduction to the application of the tracking system Introduction to the application of the tracking system

The Finder and the Finder are in use in the automotive industry for the first time, and a variety of ways to use them are proposed: RFID is commonly used in the automotive industry for tracking and traceability. There is a growing demand for customized treatment solutions.

Test Methods for Torque Transducers – Beggarbless Test Methods for Torque Transducers – Beggarbless

In recent years, the use of torque sensors has gradually increased, it can convert physical changes into accurate electrical signals, so what methods can torque sensors go through? The proven test method of torque sensors is ...

Recognition of the number of pulse positions of the encoder Recognition of the number of pulse positions of the encoder

The pulse encoder is a rotary encoder that uses the rotation pulse for signal output, and the main characteristics are the standard shape and diversified shape structure; The internal coding is stable, the signal output qiang, and the pulse value and positioning value are clear. Therefore, when choosing this type of punching encoder, ...

Precautions for P+F safety barriers Precautions for P+F safety barriers

First, it is necessary to pay attention to the capacitive and inductive resistance of cables and field equipment, explosion-proof is the explosion-proof system, in addition to the need for P+F safety barriers to reach the required explosion-proof level, the energy storage of cables and field equipment is also a key issue. Especially after parametric certification replaces system certification, engineering companies are especially ...

Points to note for encoder installation Points to note for encoder installation

1. Each electrical interface has its own characteristics, but also has different baud rate and transmission interval, which can be selected according to the specific application environment of the site, and the actual transmission interval is very related to the transmission rate, encoder and communication cable installation disturbance environment, grounding, cable material selection, etc. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top