An IT cabinet generally needs to arrange a lot of cables, including strong current cables for power supply equipment, optical fibers used for communication, and weak current cables for signal transmission. If so many cables are not well packed in a cabinet, the cables in the cabinet will be disorganized, which will affect the aesthetics and heat dissipation of the cabinet, and it will be difficult for the operation and maintenance personnel to protect the equipment.
Rittal supplies a wide range of cable management components for all areas of the IT cabinet, which can assist in the packing of cables in the cabinet, making cable packing more efficient and beautiful.
Horizontal cable management slot
In the 19" area, Rittal offers a wide range of horizontal trunkings, including cable loop and sheet metal trunking. The height of the sheet metal cable management duct can reach 2U, and the size of the cable loop management groove is also available in a variety of specifications.
Finger-shaped cable management frame
For cables on both sides of the 19" area of the 600 mm wide cabinet, Rittal supplies finger management frames for cable management. The distance between the two adjacent fingers of the finger management frame is equal to the height of the angle gauge U, which can be used for U-related cable wiring, and can complete the object-free device to the cabinet angle gauge.
Vertical cable management slots
The 800mm wide cabinet can be equipped with vertical cable management ducts outside the 19" area, and each trunking can accommodate 150-200 cables with a size of 1x2.5mm2. The front of the cable management duct is equipped with a hinged, detachable cover, which is quickly fixed by the surface and east assembly, and then completes the simple device.
Vertical cable management board
The network and server cabinets at the back of the strong current cable or fiber optic cable tie can be fixed to the cable management board. The height adjustable cable management board is suitable for cabinets of different heights, and together they can complete the content-free device.
Top cable management bracket
The top of the Rittal TSIT cabinet is fitted with brush cable entries along the depth of the cabinet for cable access from the side. The top of the cabinet can be used in conjunction with the Rittal top cable management bracket, on which various top cable ducts can be erected to complete the routing and packing of the cables on the top of the cabinet.
|
More on that
|
Rittal cables – what are the common cable faults?
Wire surface marking - according to the national standard, the wire surface should have the manufacturer name, product model and rated voltage continuous marking. This is conducive to finding the manufacturer in time when problems occur during the use of wires, and consumers must pay attention to this when purchasing wires. At the same time consume ...
|
|
Rittal Cables – the application of cables
Power system
The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (basically replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables (replacing part of the busbars) ...
|
|
The solution to the A17 fault reported by the Rittal cabinet air conditioner
1. The Rittal air conditioner does not start when it is turned on, and the A17 is faulty.
Check that the power supply voltage is 220V, normal; Detect that the battery voltage of the remote control is 3V, which is normal; Measure the fuse resistance value of the air conditioner compressor with a multimeter as infinity, which is normal.
2. The Rittal air conditioner does not start when it is turned on, and the display is not started.
|
|
What are the advantages of Rittal enclosure processing – sheet metal cabinets?
1. The cabinet and chassis products provide space for power supplies, motherboards, various expansion boards, floppy disk drives, optical disk drives, hard disk drives and other storage devices, and these spare parts are firmly fixed through the internal supports, brackets, various chassis screws or clips and other connectors inside the cabinet and chassis.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is the material of the busbar?
A: Copper busbar, aluminum busbar and steel busbar.
What is the significance of busbar coloring?
Answer: It can increase the radiation capacity, which is conducive to heat dissipation, and the allowable load current can be increased by 12-15% after coloring.
...
|
|
What is the daily maintenance method of the air conditioner? - Rittal air conditioning
1. Filter maintenance of the indoor unit: The filter screen of the indoor unit generally needs to be replaced once every two months. It is not recommended to continue to use it after rinsing, because the rinsed filter is easy to stick, so that ventilation and ventilation are not smooth, and air circulation is affected. So if it's a one-off, direct replacement, not ...
|
|
Rittal cabinets – what are the common cabinet cable management processes?
First, the waterfall shape
This is one of the older wiring patterns that can sometimes be seen. It adopts the artistic image of "Huaguo Mountain Water Curtain Cave", and directly hangs the twisted pair from the module of the patch panel, and there is a very beautiful sense of hierarchy when it is neatly distributed (24-48 per layer).
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the conditions that must be met for high-voltage appliances?
A: A. The insulation is safe and reliable;
B. Long-term operation under rated current and certain short-term overload capacity;
C. Able to carry the thermal and electrodynamic effects of short-circuit currents without damage;
D. Switching electrical appliances can be safe...
|
|
What are the main classifications of Rittal cables – power cables?
Classified by voltage level
According to the voltage level, it can be divided into medium and low voltage power cables (35 thousand volts and below), high-voltage cables (above 110 thousand volts), ultra-high voltage cables (275-800 thousand volts) and ultra-high voltage cables (1000 thousand volts and above). In addition, it can also be divided into AC ...
|
|
Rittal supports the "smart" and "low-carbon" development of new infrastructure
In recent years, with the accelerated development of China's informatization process and the continuous expansion of its scale, the demand for digital centers, as the carrier of the digital economy, is also increasing day by day. The operation of the digital center needs the support of a stable and energy-saving power system.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is a protective relay?
Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the device that trips the switch or sends out a signal.
What are the commonly used relays?
A: Current Relay, Voltage Relay, Signal ...
|
|
Rittal cables – common faults in power cables
Short-circuit fault: There are two-phase short circuits and three-phase short circuits, which are mostly caused by hidden dangers left in the manufacturing process.
Grounding fault: one or more cores of the cable break down to the ground, and the insulation resistance is lower than 10kΩ is called low-resistance grounding, and higher than 10kΩ is called high-resistance grounding. Mainly due to cable corrosion, lead ...
|
|
With the Rittal VX SE freestanding cabinet, the possibilities are endless
How to make it simpler?
How can safety be paramount?
Still worried about not being able to reduce the cost of the system?
The most suitable cabinet system is just a dream?
You've got you covered – faster, safer, simpler, compatible, and versatile...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
How much is the external design of domestic power distribution equipment products?
Answer: Front panel type, cabinet type and box type, but also indoor type, fixed type and component fixed assembly, some products use drawer cabinets.
Transmission circuits?
Answer: Erected in the power plant step-up substation and ground ...
|
|
Rittal Cables – the operation of power cable routes
The operating voltage of the cable
Generally speaking, there is a certain relationship between the operating voltage of the cable and the rated voltage. If some cable lines are not in use, they must be connected to the power grid to ensure that the cable lines are not exposed to moisture. When the neutral point is not grounded ...
|
|
Rittal enclosures – how do you maintain your robot control cabinet?
1. Maintenance content
(1) Check the heat dissipation of the controller
It is strictly forbidden to cover the controller with plastic or other materials; Leave enough space behind and on the sides of the controller (> 120mm); It is strictly forbidden to position the controller close to the heat source; It is strictly forbidden to put sundries on the top of the controller; Avoid over-the-top ...
|
|
The principle and use of Rittal cabinets
The Rittal cabinet principle
Rittal is a Germany company that specializes in the manufacture of all kinds of cabinets. It is famous for its reasonable design and guaranteed quality. Now there are many imitations in China, and imitation Rittal is also popular.
The working principle of the Rittal cabinet is to cut off the inrush current of the wire itself.
|
|
What are Rittal cabinets used for?
1. The cabinet is generally made of cold-rolled steel plate or alloy to store the computer and related control equipment, which can provide protection for the storage equipment, shield electromagnetic interference, arrange the equipment in an orderly and neat manner, and facilitate the maintenance of the equipment in the future. Cabinets are generally divided into server cabinets, network machines, etc.
|
|
Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets
▲ GGD AC low-voltage distribution cabinet:
(1) Use
GGD type AC low-voltage distribution cabinet is suitable for substations, power plants, factories and mining enterprises and other power users AC 50Hz, rated working voltage 380V, rated working current 1000-3150A distribution system, as a power ...
|
|
Rittal innovates smart services to help build new infrastructure in the 5G era
The construction of new infrastructure (new infrastructure) is a change in the upgrading and transformation of the industrial structure. As an important part of the new infrastructure, the data center provides a solid and extensive infrastructure guarantee for 5G, artificial intelligence, Internet of Things and other occupations. Rittal brings a new generation of infrastructure solutions ...
|
|