Description of the models of Rittal cabinet air conditioners

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

Here are some of the models of Rittal cabinet air conditioners:

SK3368220 air conditioner RBT3368220 300 W, 220V

SK3368320 air conditioner RBT3368320 500 W, 220V

SK3368520 air conditioner RBT3368520 1000W, 220V

SK3368620 air conditioner RBT3368620 1500 W, 220V

SK3368621 air conditioner RBT3368621 1500W, 220V

SK3368720 air conditioner RBT3368720 2000W, 220V

SK3368820 air conditioner RBT3368820 3000W, 400V

SK3370220 Smart Series Compact Air Conditioner 355W/390W230V50/60Hz

SK3370320Smart Series Compact Air Conditioner, 500W/540W230V50/60Hz

SK3370420Smart Series Compact Air Conditioner 1200W/1250W230V50/60Hz

SK3370424 Smart Series Compact Air Conditioner, 1200W/1250W, 380V

SK3370429 Smart Series Compact Air Conditioner, customized 1200W, 220V, 50/60Hz

SK3370520 Smart Series Compact Air Conditioner, 1600W/1650W, 230V

SK3370521 Compact Air Conditioner, Alarm Output, 1600W, 230V, 50/60Hz

SK3370524Smart Series Compact Air Conditioner, 1600W/1650W, 380V

SK3370620 Smart Series Compact Air Conditioner, 2000W/2080W, 230V

SK3370724 Smart Series Compact Air Conditioner, 3500W, 380V, 50Hz
Description of the models of Rittal cabinet air conditioners




More on that
Rittal cabinets – maintenance rules for network cabinets Rittal cabinets – maintenance rules for network cabinets

1. Once a month (8 hours at the end of the month), and make a maintenance record. 2. Clean the gears of the whole machine to ensure the cleanliness and normal clearance of the gears. 3. Check the gap between the two gears at the punching device of the processing department and adjust the clearance. 4. Adjust the gap between each ink roller to ensure that ...

Rittal air conditioner alarm code parsing Rittal air conditioner alarm code parsing

1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect; 2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small; 3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...

Rittal Cables – the operation of power cable routes Rittal Cables – the operation of power cable routes

The operating voltage of the cable Generally speaking, there is a certain relationship between the operating voltage of the cable and the rated voltage. If some cable lines are not in use, they must be connected to the power grid to ensure that the cable lines are not exposed to moisture. When the neutral point is not grounded ...

Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk" Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk"

The Age of Discovery, which began at the end of the 15th century, linked the world and was one of the most important historical steps in the process of human civilization. In the 21st century, in the development trend of global interconnection and China's intelligent manufacturing, the shipbuilding industry has ushered in high-energy development prospects.   Smart ships, low...

How to use the Rittal basic controller for cabinet air conditioning How to use the Rittal basic controller for cabinet air conditioning

Carefully push the decorative panel back onto the monitor until you hear it snap into place. · Reinsert the monitor into the panel or blind. · Reinstall the louver pane or panel onto the cabinet air conditioner. Reset the base controller The air conditioner in the cabinet emits a high ...

How does Rittal do it to help thyssenkrupp build competitiveness by "digital"? How does Rittal do it to help thyssenkrupp build competitiveness by "digital"?

Big data is also a strategic industry related to the future development of the steel industry. In order to remain competitive in the long term, thyssenkrupp Steel in Germany is stepping up modernization and standardization in its production-related IT areas. The Rittal Container Data Centre is essential for the successful implementation of this upgrade.

Rittal innovates the Ri4Power top-of-the-line distribution cabinet system Rittal innovates the Ri4Power top-of-the-line distribution cabinet system

Ri4Power satisfies four specifications of the system Rittal Ri4Power has developed this concept as a complete system solution for the safe and fast installation of low-voltage switchgear for machines, systems and buildings. Rittal Ri4Power It is a device that covers high-current power distribution ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

How much is the external design of domestic power distribution equipment products? Answer: Front panel type, cabinet type and box type, but also indoor type, fixed type and component fixed assembly, some products use drawer cabinets. Transmission circuits? Answer: Erected in the power plant step-up substation and ground ...

Rittal cables – measures to prevent or mitigate electrical interference Rittal cables – measures to prevent or mitigate electrical interference

1. One spare core of the control cable is grounded It has been proved in practice that when a spare core in the control cable is grounded, the amplitude of the interference voltage can be reduced to 25%-50%, and the implementation is simple, and the cost of the cable is increased very little. 2. Serious consequences will occur when electrical interference is generated.

What are Rittal cabinets used for? What are Rittal cabinets used for?

1. The cabinet is generally made of cold-rolled steel plate or alloy to store the computer and related control equipment, which can provide protection for the storage equipment, shield electromagnetic interference, arrange the equipment in an orderly and neat manner, and facilitate the maintenance of the equipment in the future. Cabinets are generally divided into server cabinets, network machines, etc.

What is the daily maintenance method of the air conditioner? - Rittal air conditioning What is the daily maintenance method of the air conditioner? - Rittal air conditioning

1. Filter maintenance of the indoor unit: The filter screen of the indoor unit generally needs to be replaced once every two months. It is not recommended to continue to use it after rinsing, because the rinsed filter is easy to stick, so that ventilation and ventilation are not smooth, and air circulation is affected. So if it's a one-off, direct replacement, not ...

Five hidden details you didn't know about Rittal cabinets and common Q&A Five hidden details you didn't know about Rittal cabinets and common Q&A

Five details that are easy to overlook: One of the hidden details: steel The most basic thing of a cabinet is to look at the steel, the Rittal standard cabinet is made of section steel, there are many masters who understand the cabinet to understand, the steel plate must be thick, just knock it with your fingers. General ...

Rittal cabinets – solutions for cooling network cabinets Rittal cabinets – solutions for cooling network cabinets

1. Deliver the cold air to the network cabinet: Because the equipment in the cabinet needs the air conditioning the most. 2. Deliver the cold air to the front of the network cabinet: because the cold air can only enter the module server chassis from the front of the server to play a role in heat exchange. 3. Precisely adjust the ...

A detailed introduction to the classification and division of Rittal cabinet products A detailed introduction to the classification and division of Rittal cabinet products

Rittal products are divided into: Rittal control cabinets: small enclosures (polycarbonate enclosures PK, junction enclosures KL, compact control enclosures EB, bus enclosures BG), compact control enclosures, plastic control enclosures KS, enclosure systems (subdivided into TS 8/SE 8 family), and...

A basic introduction to a very popular explosion-proof box in Rittal A basic introduction to a very popular explosion-proof box in Rittal

As a commonly used box in Rittal, many users do not understand the material and structure of this series of boxes. Now I would like to introduce the Rittal explosion-proof enclosure Apply: – Zones 1 and 2 or Zones 21 and 22 according to 94/9/EG – Ambient temperature range: -30°C.

Rittal Cables – an introduction to the process characteristics of cables Rittal Cables – an introduction to the process characteristics of cables

1. The impact of large-length continuous superposition combined production mode on the production of wires and cables is global and controllable, which involves and affects: (1) Production process and equipment layout All kinds of equipment in the production workshop must be reasonably discharged according to the process flow required by the product, ...

Rittal presents a number of green and innovative sanitary cabinets at CBST Rittal presents a number of green and innovative sanitary cabinets at CBST

On April 7, 2023, the 11th CBST China International Beverage Industry Technology Exhibition was grandly held at the Shanghai New International Expo Center.   As a practitioner of the concept of "intelligent manufacturing" in Germany, Rittal brings many green and innovative sanitary cabinet systems and temperature control solutions.

Rittal at the Hannover Messe 2022 in Germany Rittal at the Hannover Messe 2022 in Germany

"In 2022, with all the challenges, especially for small and medium-sized manufacturing companies – we need to think differently: if we want to support our customers and add value in our digital transformation, it's not just a single product innovation that will change. It will combine automation, digital ...

Rittal cabinets - knowledge quiz on high and low voltage distribution cabinets (31-40) Rittal cabinets - knowledge quiz on high and low voltage distribution cabinets (31-40)

31. How many modes are there for the three-phase neutral point operation of China's power system? Answer: 1. Three-phase system with no grounding (insulation) at the neutral point; 2. Three-phase system in which the neutral point is grounded through the arc suppression coil; 3. Three-phase system with direct grounding at the neutral point. 32. Use current transformers ...

What are the moisture-proof measures for Rittal cabinets – electrical cabinets? What are the moisture-proof measures for Rittal cabinets – electrical cabinets?

1. Improve the environment inside and outside the cabinet 1. We not only need to keep the electrical cabinet dry and clean, but also need to do a good job of cleaning and sanitation in the distribution room where the distribution cabinet is placed to prevent water and dust from entering the cabinet 2. The lighting environment of the distribution cabinet should be good, and it should be equipped with professional cabinet lighting ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top