Buke touch screen recommended model - MT4000 series
1. Product introduction
USING 32-BIT RISC CPU AND A STREAMLINED LINUX KERNEL, THE MT4000 SERIES OF HUMAN-MACHINE INTERFACE PRODUCTS CAN DISPLAY A VARIETY OF TRUE-COLOR GRAPHICS FORMATS, AND ITS OUTSTANDING PROCESSING SPEED AND RICH SOFTWARE FUNCTIONS CAN MEET THE NEEDS OF MOST USERS. Support with the vast majority of PLCs directly ...
|
|
Buke servo motor - the requirement of the servo feed system
1. Wide range of speed regulation
2. High positioning accuracy
3. There is sufficient transmission rigidity and high speed stability
4. Fast response, no overshoot
In order to ensure productivity and processing quality, in addition to high positioning accuracy, it is also required to have a good and fast response ...
|
|
Principle and classification of stepper motor drivers
A stepper motor driver is an actuator that converts electrical impulses into angular displacement. When the stepper driver receives a pulse signal, it drives the stepper motor to roll a fixed viewpoint (called the "step angle") in the set direction.
|
|
Buke touch screen - touch screen touch no response fault causes and treatment methods
Cause of the failure
1) The sound wave reflection stripes on the four periphery of the surface sound wave touch screen are seriously dusty or scale, resulting in the touch screen not working.
2) The touch screen is malfunctioning.
3) The touch screen control card is faulty.
4) The touch screen signal line is faulty ...
|
|
Buke servo motor - servo motor maintenance needs to pay attention to
1. Check the servo motor to ensure that there is no fatal damage outside;
2. Check the fixed parts of the servo motor to ensure that the connection is strong;
3. Check the output shaft of the servo motor to ensure the rotation and circulation;
4. Check the encoder connection line of the servo motor and the ...
|
|
Buke servo drive fault code 021.2
1. Fault code: E-01, E-02
Significance: The parameters are initialized incorrectly during power-on.
Cause: Incorrect parameter settings.
Solution: Power back on, if the fault is still reported, you need to force the parameter initialization, if it is repeated many times, it cannot be solved.
|
|
Buke human-machine interface - what principles should be considered in the design of human-machine interface?
1. The basic design principle of user-centered
In the design process of the system, the designer should grasp the characteristics of the user and discover the user's needs. In the whole development process of the system, it is necessary to continuously solicit the opinions of users and consult with users. The design decision of the system should be combined with the user's work.
|
|
How to solve the problem that the touch screen of Buke does not respond?
1. Check whether the joints of each connecting line are loose;
2. Check whether there is a conflict between the serial port and the abort number, and if there is a conflict, the resources should be adjusted to circumvent the conflict. Then check whether there are gaps in the surface layer of the human-machine interface, and if there are gaps, they should be replaced immediately. It also needs to be inspected ...
|
|
Common problems of Buke servo motor
Common problems of Buke servo motors
Why does the Kinco servo always display "Encoder counting" fault alarm?
The first thing to check is:
Whether the encoder cable is connected correctly.
Whether the encoder cable is threaded with the motor cable or other AC cables...
|
|
How to adjust the speed parameters of Buke servo motor - AC motor?
1. Change the rotational speed by changing the frequency of the mains supply
This is a common method of speed adjustment for AC motors. The power supply frequency can be adjusted to the desired speed by adjusting the inverter, transformer, and other equipment.
2. Change the rotational speed by changing the voltage
In some special cases ...
|
|
Buke servo motor - what are the components of AC servo motor?
1. a frame
The frame structure varies depending on the motor cooling method, protection type, installation method, and purpose. According to its material classification, there are several types of cast iron, cast aluminum and steel plate structures. Cast iron frame with ribs. The base is connected to the end cap and fastened with bolts. Cast aluminum machine base generally does not have ...
|
|
Buke servo motor - AC servo motor vibration fault analysis
Mechanical
1. Bearing
The bearing clearance on the lead screw housing is too large after wear, or the bearing roller elements and cages are severely worn due to the lack of grease in the bearing, resulting in excessive loads. After bearing wear, the clearance is too large, which will cause the coaxiality error between the center of the motor rotor and the center of the lead screw.
|
|
Analysis of the cause of the fault code 004.0 of the servo drive
1. Excessive load: Confirm whether the connected load exceeds the rated load capacity of the drive. The load is too large and needs to be reduced appropriately to ensure that the current is within the allowable range.
2. The driving system parameter setting is incorrect: check whether the driver parameter setting is correct.
3、 ...
|
|
Buke servo motor - the regular maintenance content of AC motor
1. Wipe the motor. Remove the dust and sludge on the outside of the motor base in time. If there is a lot of dust in the environment, it is best to clean it once a day.
2. Check and wipe the motor terminals. Check whether the junction box wiring screws are loose or burned.
3. Check the screws of each fixed part ...
|
|
Buke servo motor - the cause of common faults in motors
1. Sweeping: Sweeping is generally caused by friction of the stator and rotor due to bearing damage, shaft bending, or improper assembly during maintenance. In the process of overhaul and assembly of the motor, the parts of the motor should be kept clean, and the assembly of the end cover, bearing, etc. should be reasonable and not barbaric construction, otherwise ...
|
|
Common models of Buke inverters
Common models of Buke inverters
Buke CV100 series mini inverter
The output frequency is 0-300Hz
The carrier frequency is up to 15kHz, which effectively reduces the noise of the inverter
It is equipped with RS-485 communication port as standard and supports Modbus communication protocol
Sleep/wake function, inner ...
|
|
Buke servo drive - the wiring method of the stepper driver and PLC
1. First of all, the first step is to power the 24V power supply: brown positive blue negative yellow and green wire.
2. Then it is necessary to connect the two sets of wires of the motor to the A+ A-, B+ B- of the driver.
3. Then connect the 24v power supply-v to the GND of the driver.
4. And then ...
|
|
Buke servo motor - six common faults and treatment methods of servo motors
1. The motor temperature is too high or the smoke is faulty
Cause:
1. Excessive load
2. Two-phase operation
3. Air duct blockage
4. The ambient temperature increases
5. Stator windings are short-circuited between phases or turns
6. Stator winding grounding
7. The power supply voltage is too high ...
|
|
The solution of the alarm code 08 when the servo drive is accelerated
1. Please check the motor power line to confirm whether there is a short circuit in the phase wire of the motor
2. If there is no short circuit in the phase line of the motor, it is determined that the internal power tube problem of the driver is determined
|
|
Buke servo motor - what is the impact on the operation of the servo motor of the fiber laser cutting machine?
Fiber laser cutting machine has been widely accepted by the society and used in many industries, welcomed by customers, helping customers improve production efficiency and improve product competitiveness. But at the same time, we don't know much about the functions of the machine components, so today we will talk about fiber lasers.
|