Megmeet Inverter - Precautions for the Use of Inverter (11-21)
11. For the occasion when the inverter drives the ordinary motor for constant torque operation, long-term low-speed operation should be avoided as much as possible, otherwise the heat dissipation effect of the motor will become worse and the heating will be serious. If long-term operation at low speed constant torque is required, a variable frequency motor must be selected.
12. For the promotion of negative ...
|
|
Common faults and solutions of Megmeet inverter
Fault one
Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation
Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...
|
|
Solutions to common faults of Megmeet inverter (2)
Fault three
Fault phenomenon: There is a rebound phenomenon when the rotation starts
Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5)
2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11 ...
|
|
Megmeet drives – a common fault in low-voltage drives
External electromagnetic interference can easily cause malfunctions
If there are interference sources around the inverter, they will invade the inside of the inverter through radiation or power lines, causing the control loop to malfunction, causing abnormal operation or shutdown, and even damage to the inverter in severe cases. Noise suppression on the outside ...
|
|
Megmeet PLC - What are the steps to complete PLC commissioning?
1. Check the circuit according to the drawing (without power transmission)
The drawings of the general PLC system include two parts: the drawings in the cabinet and the drawings outside the cabinet; The drawing in the cabinet refers to the wiring diagram inside the cabinet; The out-of-cabinet drawings are the wiring diagrams of all electrical cabinets.
This part needs to be checked for;
...
|
|
Common faults of Megmeet drives and how to deal with them
1. When the oscilloscope looks at the current monitoring output of the driver, it finds that it is all noisy and cannot be read
Cause: The current monitoring output is not blocked from the AC power supply (transformer).
Solution: You can use a DC voltmeter to detect and investigate.
2. Servo motor high speed ...
|
|
Megmeet inverter maintenance and testing method
Megmeet inverter maintenance and testing method
1. The Megmeet rectifier module is damaged
It is usually caused by grid voltage or internal short circuit. In the case of sweeping internal short circuits, the rectifier bridge is replaced. When dealing with shortcomings on site, the user power grid should be checked.
Such as electricity ...
|
|
Megmeet inverter - the daily maintenance and overhaul of the inverter
1. Regularly dust the inverter, focusing on the rectifier cabinet, inverter cabinet and control cabinet, if necessary, the rectifier module, inverter module and the circuit board in the control cabinet can be removed for dust removal. Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. The inverter is due to the ...
|
|
Various welding methods for Megmeet welding machines
1) Hand arc welding (STICK)
Shielded Arc Welding (abbreviated SMAW) in English,
The principle is: the arc occurs between the coating electrode and the base metal, and the welding method of arc thermal ablation electrode and base metal is used. The outer layer of the electrode is covered with solder, which is dissipated in case of heat.
|
|
Megmeet PLC - Introduction to the basic structure of PLC controller
1. Power supply
The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...
|
|
Megmeet PLC - the core components of PLC introduction
(1) Central Processing Unit (CPU)
The central processing unit (CPU) is the control center of the PLC. It accepts and stores user programs and data typed from the programmer, checks the status of the power supply, memory, I/O and alert timer in accordance with the functions assigned by the PLC system program, ...
|
|
Megmeet welding machine - resistance welding or laser soldering who is more suitable for electronics industry applications
Today's electronics industry revolves around high-speed communication and supercomputing on the Internet, and the requirements for electronic products are getting higher and higher. A large number of micro-precision electronic products are constantly testing the response speed and level of major enterprises in the market. Electronics manufacturers perform real-time, accurate ...
|
|
Megmeet servo drive - common faults and treatment methods of servo drives
1. The motor runs differently in both directions
Cause of failure: The phase of the brushless motor is wrong; The deviation potentiometer is in the wrong position.
Solution: Detect or detect the correct phase; Reposition the potentiometer.
2. The motor speed is abnormal
Cause of failure ...
|
|
Megmeet inverter mv600 alarm code ENOC2
1. If there is a sharp acceleration or deceleration, please extend the acceleration and deceleration time.
2. Avoid rapid increase in load.
3. Check whether there is a short circuit in the UVW of the motor terminal.
4. The module is damaged, and the drive circuit is damaged, resulting in an overcurrent alarm.
...
|
|
Megmeet drives – what are the basic requirements for regular replacement of drive components?
1. It is necessary to figure out the basic parameters and shape of the device that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage ...
|
|
What are the characteristics of Megmeet PLC - PLC working process?
(1) The PLC adopts the working mode of centralized sampling and centralized output, which reduces the influence of external interference.
(2) The working process of PLC is the process of cyclic scanning, and the length of cyclic scanning time depends on the speed of instruction execution, the length of the user program and other factors.
(3) Output ...
|
|
Megmeet PLC – three connection methods for PLC and frequency converter
1. Use the analog output module of the PLC to control the inverterThe analog output module of the PLC outputs a 0-5V voltage signal or a 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but requires the option to ...
|
|
Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (11-20)
11。 If the interface board does not communicate with the monitor and does not establish communication with the interface board, the interface board will reset the monitor every 5 seconds, and if the communication is not established within 3 minutes and 30 seconds, it will be judged as a serious fault. Whether the communication line is normal, check whether the terminal is correct; Whether the I/O board is working properly. Especially the work ...
|
|
Megmeet inverter - what are the control methods of the inverter?
Sinusoidal Pulse Width Modulation (SPWM) control mode
It is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of industry. However, this type of control is at low frequencies, ...
|
|
Megmeet PLC - the installation method and functional requirements of the PLC
Installation:
The installation mode of PLC system is divided into centralized, remote I/O and distributed with multiple PLC networking.
Centralized does not need to set up the drive remote I/O hardware, the system response is fast, and the cost is low; Remote I/O is suitable for large systems with a range of ...
|