The "Eastern Data and Western Computing" project aims to promote the rational layout of data centers, optimize supply and demand, green intensification and interconnection, so that the computing resources in the west can more fully support the computing of data in the east and better empower the country's digital development.
As an important part of the data center, IT infrastructure provides a solid foundation for industries such as artificial intelligence, big data, and cloud computing. The IT infrastructure solutions that meet the requirements of the new infrastructure will inject surging momentum into the green, intelligent and high-quality development of data centers of the "Eastern Data and Western Computing" project.
On March 9, 2023, the FR IT new product launch event organized by Rittal was held in Beijing. As a leader in the industrial and information industry, Rittal brings the latest technologies and solutions of innovative FR IT infrastructure to the audience in the field of data centers, comprehensively presents the practical results of empowering intelligent manufacturing in the era of big data to the industry, focuses on the opportunities and challenges brought by the digital era, and comprehensively interprets the technological evolution direction of future data centers in the context of the "Eastern Data and Western Computing" policy.
Straight to the scene
General Manager Wang Jiangbing appeared at the press conference and accepted an exclusive interview
Mr. Wang Jiangbing, General Manager of Rittal, delivered a speech at the new product launch conference and shared with the media and the audience the new products and IT industry system solutions to help build the 5G era, especially in the context of "Eastern Data and Western Computing", and Rittal's strategic support for the localization of new infrastructure and intelligent manufacturing.
"We will cooperate with industrial development, combine Rittal's years of industry experience and advanced practices in data center projects in international and developed regions in eastern China, bring green, energy-saving and consumption-reducing IT solutions to customers in western China, and help the high-quality development of computing power facilities and data centers in western China." Wang Jiangbing, general manager of Rittal said in an exclusive interview at the scene.
Big coffee gathers to take the lead in "carbon".
At the meeting, the President of Rittal, Vice President of Sales, Channel Director and Manager of ITCC Competence Center jointly released new products, respectively on the interpretation of Rittal's concept of data center in the context of "dual carbon" and "Eastern Data and Western Computing", a comprehensive and thorough introduction of IT system products, and an IT channel policy to build a win-win ecological chain.
The atmosphere of the Rittal on-site event was enthusiastic
The new product launch conference attracted many professional media and customers to stop and stay, and the staff answered in a timely manner, and showed customers the innovative design features and unique charm of Rittal's two products, Rittal's new FR IT and edge data center in 2023, which won many praises.
FR IT is the first of its kind in China to launch a new generation of high-quality cabinets, with an innovative modular frame design that can be used to install and place 19" rack-mounted hardware devices in accordance with industry standards (EIA-30-E), including servers, voice, data, network equipment, UPS and batteries, etc., which can be widely used in indoor environments such as data centers or small and medium-sized computer rooms. At the same time, the through-hole ratio design of up to 75% makes the heat dissipation of the data center room faster and the maintenance more efficient, which can meet the country's needs for energy saving, high efficiency and lightweight in the construction of the data center of the "Eastern Data and Western Computing" project.
ecology
As we all know, Rittal is actively exploring and practicing the development concept of intelligent manufacturing and Industry 4.0, continuously innovating, exploring green, intelligent and sustainable cutting-edge industrial information technology, integrating it into industry, contributing full value chain services to help enterprises achieve digital transformation, and playing an active role in it through its own practice.
From international to China, from large-scale data center projects such as Qinhuai, to municipal and university projects, to cooperation with customers in the automobile manufacturing industry, whether it is a micro-module suitable for large enterprises or an edge data center solution suitable for small and medium-sized data centers, Rittal is actively promoting the collaborative development and innovation of industrial information technology in all walks of life, and working with customers to create ecological cooperation in the industrial chain.
Emerging technologies and fields will further empower the efficient operation of the data center field, which requires more stable and high-quality support teams and products. Rittal will take FR IT localization products as a new starting point, based on mature IT solutions, to contribute to the development and upgrading of data centers in the western region and even the whole country, help China's industrial digitalization "footsteps" go faster and more stable, and share opportunities with the industry.
|
More on that
|
Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets
1. Normal power transmission operation process of low-voltage distribution cabinet:
1. All load switches are disconnected, confirm that the switches have at least one breakpoint;
2. Confirm that the power switch is in the disconnected position;
3. Send the power supply to the operation circuit, and the status indication is normal;
4. The incoming switch is - isolated ...
|
|
Rittal Cables – the scope of application for wires and cables
Power system
The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables, which are basically replaced by plastic power cables), rubber sheathed cables, overhead insulated cables, branch cables (replacing part of the busbars), ...
|
|
Introduction to the features of Rittal cabinet air conditioners
1. Extremely high;
2. The appearance is RAL7035 color (gray and white), which is consistent with the cabinet;
3. Ultra-thin design, the installation method can be plug-in and embedded;
4. The power supply range, single-phase and three-phase power supply models can be selected;
5. Control ...
|
|
Rittal RBT side-mounted cooling unit cabinet air conditioning
Rittal RBT cooling units – the most economical option for you! If a limited budget makes you extremely cost-conscious, then RBT is the choice for your ambition. After large-scale assembly line production, as well as the excellent functions of the cooling unit itself, the RBT has achieved a very high ...
|
|
Rittal cabinets – heat dissipation and dust protection for electrical cabinets
1. Built-in air conditioner for heat dissipation
The cabinet is equipped with a refrigeration system, the evaporator and power devices are installed inside the cabinet in a closed manner, and the condenser and compressor are placed in the external circulation air duct or outside the cabinet. Since the power unit is sealed in the cabinet, as long as the appropriate sealant is used ...
|
|
Rittal enclosures – what are the functions of the enclosure?
The function of the cabinet is security
Packing mission-critical IT equipment into lockable cabinets makes it easier for network administrators to limit the number of people who can flip out the cabinets.
The function of the cabinet is heat dissipation
Estimate how much heat your device is ...
|
|
Alarm code analysis for Rittal chillers
1. E1: Temperature sensor failure
2. E2: Humidity sensor malfunction
3. E3: Compressor overload protection
4. E4: Compressor phase loss protection
5. E5: Compressor short circuit protection
6. E6: Compressor switch failure
7. E7: Fan failure
...
|
|
Rittal cables – common faults in industrial control cables
1. Flashover fault: The industrial control cable is in a good insulation state at low voltage and will not have a fault. However, as long as the voltage value rises to a certain range, or a certain voltage continues to rise after a period of time, then it will instantly break through the insulator and cause flashover fault.
2. Long-term ...
|
|
Rittal cables – what are the types of industrial wires and cables commonly used?
Industrial wires and cables include single-core wires and cables, rubber cables, shielded control cables, flame-retardant cables, fire-resistant cables, etc.
Single-core wire and cable
It means that there is only one conductor in the insulation layer, the common BV wire, and B represents the wiring; V stands for insulating polyvinyl chloride. Suitable for AC ...
|
|
Running seamlessly, Rittal develops with reliable quality "pulsating" energy storage
Reliable supply wherever you are
Tesvolt's large-scale industrial battery storage systems are based on standard products made by Rittal and guarantee a continuous power supply on the top of a mountain, by the sea or in the desert.
The mountain peaks rise high above the crystal clear ...
|
|
Rittal cables – the difference between power cables and control cables
The power cable is used to transmit and distribute large-scale electrical energy in the main line of the power system, and the control cable directly transmits the electric energy from the distribution point of the power system to the power connection line of various electrical equipment and appliances. The rated voltage of power cables is generally 0.6/1KV and above, and the control cables are mainly 4 ...
|
|
What are the advantages of Rittal enclosure processing – sheet metal cabinets?
The development of sheet metal cabinet and chassis processing industry is getting bigger and bigger, which is due to the rapid development of society, the popularity of high-tech products, server cabinets, computer main chassis, equipment shells, etc. What are the advantages of sheet metal cabinet enclosures?
1. Cabinet and chassis products provide space for ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is a control device?
Answer: It is mainly used to control the switching appliances of the powered equipment and the combination of control, detection, protection and regulation equipment associated with these switching appliances.
What is Overcurrent?
A: Any electricity that exceeds the rated current.
...
|
|
Rittal enclosures – a classification of low-voltage distribution cabinets
(1) Classified according to the requirements of the power supply system
1) The first-level power distribution equipment is collectively referred to as the power distribution center. They are centrally installed in the substations of the enterprise, and the electrical energy is distributed to the subordinate distribution equipment in different locations. This level of equipment is close to the step-down transformer, so the electrical parameters are high.
|
|
Rittal cabinets - judgment and handling of common faults in high-voltage switchgear
1. Judgment and treatment of sudden tripping fault of high-voltage switchgear during operation
1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature.
2) Judgment method: judging the cause of the fault can be based on the relay off, remote ...
|
|
Analysis of the interior of the Rittal cabinet TS8 series
RITTAL TS8 cabinet front door door rear sealing plate, a galvanized mounting plate 16-fold profile
ISV-TS 8 cabinets with a maximum current of 1600 A single door
Can be installed in all TS 8 cabinets of the same height and depth
- Can be pre-installed in configurations
- Available in the spirit ...
|
|
Rittal cables – the common code for cables
Usage code - not marked as power cable, K- (control cable), P- (signal cable);
Conductor material code - not marked as copper (can also be marked as CU), L- (aluminum);
Inner Sheath Code – Q-(Lead Packed), L- (Aluminum Cladding), H- (Rubber Jacket), V-(Polyvinyl Chloride ...
|
|
Introduction and classification of Rittal switchgears
An introduction to Rittal switchgear
The switch cabinet is a kind of electrical equipment, the outer line of the switch cabinet first enters the main control switch in the cabinet, and then enters the sub-control switch, and each branch is set according to its needs. Such as instrumentation, automatic control, motor magnetic switch, all kinds of AC contactors, etc., ...
|
|
Rittal cabinet - distribution cabinet installation method, installation process and precautions
First, the construction process
Equipment unpacking inspection→ equipment handling, → cabinet (plate), basic installation, → above the cabinet (plate), bus preparation, → cabinet (plate), secondary circuit wiring, → cabinet (plate) test adjustment, → power transmission operation acceptance
Second, the construction process
1. Equipment unpacking inspection, installation ...
|
|
Rittal innovates smart services to help build new infrastructure in the 5G era
The construction of new infrastructure (new infrastructure) is a change in the upgrading and transformation of the industrial structure. As an important part of the new infrastructure, the data center provides a solid and extensive infrastructure guarantee for 5G, artificial intelligence, Internet of Things and other occupations. Rittal brings a new generation of infrastructure solutions ...
|
|