As the "guardian" of the cabinet, the lock system is also an important accessory choice in the cabinet system. Locking systems include fasteners, locks, keys, handles, and cylinders, among others. The lock cylinder refers to the module that is replaced for different locks and keys.
01. Personalized configuration: customers only need to simply replace the lock cylinder of the small box to achieve non-standard personalized configuration.
02. Short delivery time: For the supply of large quantities of lock cylinders, Rittal provides a seamless supply chain combination to achieve short delivery time and high efficiency.
03. High security: The lock cylinder of the small box can help customers improve the overall safety of the box.
Today, let's take a closer look at the various advantages and performance of small box cylinders.
Introduction of the box lock cylinder
01. A-type lock cylinder
Type A cylinders are suitable for EB, BG, AE as well as web wall mounted enclosures AE
Material: Zinc die casting
Length: 27mm
Available Styles: 7mm Rectangle/8mm Rectangle/7mm Triangle/8mm Triangle/Screwdriver/Daimler Car/3mm Double Tooth/Blade Type/6.5mm Triangle (CNOMO)
02. F-type lock cylinder
The F-cylinder is suitable for EL three-section housings
Material: Zinc die casting
Available Styles: 7mm Rectangle/8mm Rectangle/7mm Triangle/8mm Triangle/Screwdriver/Daimler Car/3mm Double Tooth/Blade Type/6.5mm Triangle (CNOMO)
03. F-type lock cylinder is suitable for EL three-section cabinet
Type B cylinder for EB, BG, AE (cam locks), not for AE (with three-point locks)
* With lock number 3524E, with 2 keys
Form: B
Material: Zinc die casting
04. Comfortable handle
Can be used in EL three-section cabinets
1. Used for lock cylinder and padlock. The lock cylinder can be selected as F-type lock cylinder or safety lock cylinder and button lock cylinder
2. For semi-cylindrical cylinders, you can choose between safety cylinders and pushbutton cylinders or cylinders in accordance with DIN 18252
Semi-cylindrical cylinders according to DIN 18252 (three keys per cylinder)
04. Micro comfort handle (AE cabinet height from 380mm, AE cabinet width from 300mm)
Available for AE (with cam lock) cabinets and EL three-section cabinets
● For the lock cylinder, you can choose F-type lock cylinder or safety lock cylinder and button lock cylinder
● For semi-cylindrical cylinders, you can choose between safety cylinders and pushbutton cylinders or cylinders in accordance with DIN 18252
05. Ergoform-S handle
Available for AE (with 3-point lock) and KS (with 3-point lock) cabinet
● The standard type can be selected with semi-cylindrical lock cylinder - safety lock cylinder and button lock cylinder, DIN 18252 or lock cylinder - type A lock cylinder
● The standard of the plastic control cabinet KS can be semi-cylindrical lock cylinder - safety lock cylinder and button lock cylinder, DIN18252 or lock cylinder - type A lock cylinder
To provide customers with a variety of diversified choices, escort for the safety of the box, Rittal is a professional box solution provider, customer satisfaction, is the driving force for our continuous progress!
Article source: Rittal service account
|
More on that
|
What is the difference between a control cabinet and a distribution box?
One. The nature is different
Distribution box: There is a large amount of parameter data in the distribution box. It generally constitutes a low-voltage distribution box.
Control cabinet: The control cabinet is to assemble the switch cabinet, measuring instruments, protection devices and auxiliary equipment in a closed or semi-enclosed metal cabinet or screen according to the requirements of electrical wiring.
|
|
Analysis of the reasons why the Rittal Rittal cabinet air conditioner shows OL
The probable cause is the phenomenon of the compressor protection device tripping.
Compressor overload protection will trip, indicating that the system is too high-pressure, the pressure is too high, or the overheating current is too high.
Causes and elimination of high pressure and overheating:
1. Too much refrigerant. Reduce the refrigeration dose appropriately.
2, ...
|
|
Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets
What is Arc?
Arc is a physical phenomenon generated during the operation of electrical equipment, which is characterized by very strong light and high temperature.
Classification of electrical loads?
Primary load: those whose power supply interruption will cause personal injury or death; or those that will cause significant losses politically or economically.
...
|
|
Rittal innovates the Ri4Power top-of-the-line distribution cabinet system
Ri4Power satisfies four specifications of the system
Rittal Ri4Power has developed this concept as a complete system solution for the safe and fast installation of low-voltage switchgear for machines, systems and buildings. Rittal Ri4Power It is a device that covers high-current power distribution ...
|
|
Introduction to the process characteristics of Rittal cabinets
1. The cabinet door is off the ground 25. 5mm
2、2. The 5mm thick mounting plate has 23mm wide U-shaped curved edges on both sides, which makes the mounting plate stronger and easier to handle
3. The three cable introduction cover plates at the bottom of the box can be replaced by each other, which is easy to move, easy to import cables, and easy to open holes into the line
...
|
|
Rittal Cables – an introduction to the advantages of industrial control cables
Fulfillment of the requirements of many electrical appliances: In the manufacture of industrial control cables, the relevant standards for the transmission of various information are fully considered. This ensures that the industrial control cables can meet the performance requirements of many electrical appliances in their daily work.
Abrasion Resistance: Industrial Control ...
|
|
Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?
1. In principle, the power cord and network cable of the cabinet should be sorted out separately;
2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other;
3. If there are too many devices in the cabinet, the equipment should be numbered;
4. For each line ...
|
|
Rittal rittal stage coating method and function
Rittal coating method and function degreasing, nano-ceramic pretreatment, washing, used for anti-rust maintenance, used to improve the adhesion characteristics of lacquer. The conversion coating anodic dip primer of the nano-ceramic is evenly applied to the individual surfaces, edges and cavities. This constitutes a high corrosion protection ...
|
|
What are the moisture-proof measures for Rittal cabinets – electrical cabinets?
1. Improve the environment inside and outside the cabinet
1. We not only need to keep the electrical cabinet dry and clean, but also need to do a good job of cleaning and sanitation in the distribution room where the distribution cabinet is placed to prevent water and dust from entering the cabinet
2. The lighting environment of the distribution cabinet should be good, and it should be equipped with professional cabinet lighting ...
|
|
When winter arrives, Rittal heaters bring warmth to the cabinets
We know that electronic and electrical equipment is installed in the electrical cabinet, in fact, there are working temperature requirements, the general storage temperature can not be lower than minus 25 degrees, the working temperature can not be lower than minus 20 degrees, but now the outdoor temperature in the north is very simple to reach the lower limit of this working temperature, this time heating ...
|
|
Rittal cabinets – the composition and function of low-voltage distribution cabinets
The power distribution panel is mainly composed of incoming cabinets, outgoing cabinets, capacitor cabinets, metering cabinets, etc.
Incoming cabinet: also known as the receiving cabinet, is a device used to receive electrical energy from the power grid (from the incoming line to the busbar), generally installed with circuit breakers, CT, PT, isolation knives and other components.
Outlet cabinet: ...
|
|
The Rittal enclosure model 6380.510 is designed to be ultra-slim and matched to the embedded devices
Product Introduction
Brand: Rittal cabinets
Product model 6380.510
Aluminum box, strong thermal conductivity, excellent passive heat dissipation. For relatively small panels and control schemes. The ultra-slim design matches the embedded device and takes up almost no space.
Type: Support ...
|
|
Rittal's entire value chain system supports Automotive Industry 4.0
In China, intelligent production is not only a national strategy to guide industrial innovation, but also has evolved into a tangible reality in the process of development: the "future" cars and new infrastructure produced by digital and information-based production have come to people from the illusory scenes in movies or novels. Appearance...
|
|
Rittal cabinets – installation steps and rules for cabinet placement
Cabinet installation steps:
1. Before installing the cabinet, check whether the exhaust device of the cabinet is stable, whether the number of equipment support plates is complete, and whether the pulleys and support columns are stable.
2. The model, specification and device orientation of the cabinet should meet the planning requirements.
3. Cabinet ...
|
|
Analysis of the fault codes of the Rittal cabinet air conditioner
1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect;
2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small;
3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...
|
|
Rittal enclosures – the details that need to be taken into account for the daily care and maintenance of your enclosures
1. Avoid light
The server is required to operate in a constant temperature environment, and direct sunlight will increase the temperature in the computer room, which will damage the display and shorten its service life. When operating in IDC and ISP data centers, it is impossible to see a ray of sunshine.
So, in ...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50)
41. Can power lines be divided into according to the erection method?
A: Overhead power lines and cable lines.
42 What is a protective relay?
Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the switch to trip or send out a signal ...
|
|
Rittal cabinet - distribution cabinet installation method, installation process and precautions
First, the construction process
Equipment unpacking inspection→ equipment handling, → cabinet (plate), basic installation, → above the cabinet (plate), bus preparation, → cabinet (plate), secondary circuit wiring, → cabinet (plate) test adjustment, → power transmission operation acceptance
Second, the construction process
1. Equipment unpacking inspection, installation ...
|
|
The Rittal RiEDC series has been named the IT Solution of the Year 168
The Rittal RiEDC series has been awarded Solution of the Year at the IT168 Technical Excellence Awards.
The "Technical Excellence Award" is jointly judged by professional users of the big data industry, technical experts and the media, and its criteria are based on innovative solutions recognized by the market and customers, ...
|
|
Rittal cabinet - the introduction and function of network cabinets
What is a Network Cabinet?
The network cabinet is a kind of rectangular cabinet composed of two parts: frame and cover, which can install switches, optical fiber adapters, optical fiber distribution frames and other equipment in a cabinet, with electromagnetic barrier, noise blocking, ventilation and heat dissipation, anti-vibration, anti-corrosion, etc.
|
|