When the Delta inverter is powered on, the uptube drive voltage is established

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

One is hardware, similar to the CPU reset circuit, which gives the downtube a short high-level drive pulse during the initial power-up, and then the voltage drops to 0 to cut off the downtube.

The second is software, when the CPU is operating normally, it outputs a square wave pulse that only needs to be turned on by the lower three tubes, so that the upper tube driving voltage can be established.

The third is to complete the establishment of the upper tube drive voltage without any special structure, and complete the establishment of the upper tube driving voltage with the operating principle of the inverter. When the inverter gets the start instruction, the upper tube driving pulse is announced by the CPU, when it drives the optocoupler, the upper tube is not on because the optocoupler secondary has no operating voltage, but when the lower tube driving pulse announced by the CPU drives the optocoupler, because the lower tube driving voltage is now established, the lower tube is turned on, and the capacitance of the upper tube driving circuit forms a charging current loop through the conduction of the lower tube, and then the power supply voltage is obtained, when the second upper tube pulse arrives, the driving voltage is now established, and the upper tube is normally conducted, and then enters the normal operating condition.

                            When the Delta inverter is powered on, the uptube drive voltage is established

More on that
Precautions before installation of Delta inverters Precautions before installation of Delta inverters

Delta's inverter should be thoroughly inspected for initial installation or long-term use. The items and methods to check are as follows: 1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dry for 4 hours (60°C) or in ...

Precautions for the operation of Delta servo motors Precautions for the operation of Delta servo motors

1) The AC servo motor works by means of a dedicated drive. Do not connect the commercial power supply (100/200V, 50/60Hz) directly to the line of the servo motor, otherwise the servo motor will not work properly and the servo motor will be permanently damaged. ...

Delta's servo brake circuit wiring method Delta's servo brake circuit wiring method

The wiring method of the braking circuit of the Delta servo is to short the brake resistor inside the driver at the P and C terminals of the Delta servo. The brake of the motor is directly connected to the external 24V drive, which is controlled by an external circuit. Delta servo is developed according to the needs of customers who use different machinery; Provide a full range of ...

Delta's touch screen downloads programs and communication settings Delta's touch screen downloads programs and communication settings

1. Touch screen download program (1) Device software DOPSoft; (2) The communication line uses a square port data line; (3) device drive; (4) Configuration screen; (5) In the Stuff, select Download All Materials. 2. Communication settings (1) Touch screen settings ...

Delta touch screen models and advantages Delta touch screen models and advantages

Human Machine Interface (HMI) is a digital product that allows operators to communicate with automation equipment. The human-machine interface provides a variety of communication ports to facilitate communication with a variety of equipment, and the touch panel allows the operator to intuitively set parameters.

The parameter that needs to be set for the inverter - Delta The parameter that needs to be set for the inverter - Delta

There will be some difference between the parameter setting of the inverter at the factory and the requirements of practical application. Therefore, the reasonable setting of the inverter parameters is directly related to whether the inverter can be used normally, which is of decisive significance. General-purpose inverters generally have dozens or even hundreds of functional parameters.

Precautions for long-term idle use of Delta inverter Precautions for long-term idle use of Delta inverter

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems: ...

Requires an inverter speed control application – Delta Requires an inverter speed control application – Delta

Inverter is a kind of speed regulation equipment, where is there a place to use motor speed regulation, especially asynchronous motor speed regulation, will use inverter, now it is mainly used in industrial equipment on a large scale, because the motor is the heart of industry, and three-phase asynchronous motor occupies the vast majority of the share, ...

Problems in the use of Delta inverters and Delta motors Problems in the use of Delta inverters and Delta motors

Delta's motors are the most frequently used rotating things so far, and with the development and spread of Delta inverters, they need to be used in conjunction with inverters. However, in the process of combining inverters and motors, it is inevitable to encounter a lot of ...

Basic conditions for Delta UPS uninterruptible power supply Basic conditions for Delta UPS uninterruptible power supply

1. Visually inspect the UPS and battery (or other energy storage) equipment for obstacles, and properly cool the surrounding area. 2. Ensure that there is no abnormal operation or positive warning on the UPS panel, such as: overload or overdischarge of the battery close to it. 3. Check if there is battery corrosion or other shortcomings ...

Debugging Delta's inverter method Debugging Delta's inverter method

1. Acceleration and deceleration time The acceleration and deceleration time is usually confirmed by the rise and fall of the frequency setting signal. In the commissioning of Delta inverters, it is often used to set a long acceleration and deceleration time according to the load and experience value, and the frequency rise rate of the motor must be constrained when it accelerates to avoid overcurrent. When slowing down, ...

Installation steps of the reducer - Delta Installation steps of the reducer - Delta

Correct installation, operation and maintenance of the reducer is an important part of ensuring the normal operation of mechanical equipment. Therefore, when you install a planetary reducer, it is necessary to carefully assemble and operate it in strict accordance with the following matters related to the operation of the device. ...

Problems in the inverter application – Delta inverters Problems in the inverter application – Delta inverters

1. Harmonic problems The equipment that plays the role of switching in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics generally have a greater impact on the motor load and cause torque ripple; The higher harmonics increase the leakage current of the inverter's output cable, making ...

Delta's inverter power-on debugging method Delta's inverter power-on debugging method

After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.

The cause of the damage of the inverter - Delta inverter The cause of the damage of the inverter - Delta inverter

First, the heat dissipation of the inverter is not good In fact, we all know that too high a temperature has a damaging effect on any equipment, just like a human brain, too high a temperature will also burn out the brain, in fact, the same is true for inverters. When the temperature rises, because of the sensitivity of semiconductors to temperature, the inverter ...

In 2020, Delta once again won the Outstanding Human Resource Optimization Award In 2020, Delta once again won the Outstanding Human Resource Optimization Award

Not long ago, Delta was awarded the "2020 Excellence Award for Optimal Allocation of Human Resources Resources" by the Human Resource Management Service Project Organization "Future", which stood out from more than 5,000 companies. This is also the second time since 2018 that Delta has won this honor. Delta ...

Delta's inverter power-on debugging method Delta's inverter power-on debugging method

After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.

Inverter environmental installation requirements and methods - Delta inverter Inverter environmental installation requirements and methods - Delta inverter

1. The environmental requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions that require no direct sunlight, no corrosive gas and flammable gas, and less dust, with an altitude of less than 1000m. ...

The reason for the shaking of the inverter for the motor - Delta The reason for the shaking of the inverter for the motor - Delta

When using the motor dragged by the inverter, sometimes the motor flutters and the over-fire flutter may burn out the motor and cause immeasurable losses. So what is the reason for this phenomenon? 1. The motor is damaged ...

Pulse control wiring method for Delta servo drives Pulse control wiring method for Delta servo drives

Parameter settings P1-XX are the basic parameters P1-00 pulse method selection, *** bit selection is 2, that is, pulse train + direction P1-00 signal logic picking, the third digit is selected as 0 or 1, which is the positive logic or anti-logic, X0XX or X1XX P1-01 Control form selection, pick ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top