The principle and operation method of Delixi inverter operation

Create Date: 2024-8-30 12:03:23|Source: Delixi

The principle and operation method of Delixi inverter:

                                 The principle and operation method of Delixi inverter operation

1. No-load energizing test of inverter

1. Ground the grounding terminal of the inverter.

2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.

3. Check whether the factory display window of the inverter is normal, if it is incorrect, it should be reset, otherwise it is required to be returned.

4. Understand the operation key of the inverter. The general inverter has 6 keys such as RUN, STOP, PROG, DATAPENTER, UP and ▲, and DOWN, and the definition of the operation keys of different inverters is basically the same. In addition, some inverters also have functional keys such as MONITORPDISPLAY, RESET, JOG, and SHIFT.

2. The inverter runs with motor without load

1. To set the power and number of poles of the motor, the operating current of the inverter should be considered.

2. Set the maximum output frequency, fundamental frequency, and torque characteristics of the inverter. The general inverter is equipped with a number of VPf curves for users to choose, and users should select the appropriate VPf curves according to the nature of the load when using. In the case of fan and pump loads, the torque operation code of the inverter should be set to the variable torque and reduced torque operation characteristics. In order to improve the low-speed function of the inverter when starting, so that the torque output of the motor can meet the requirements of the production load, the starting torque should be adjusted. In the frequency conversion speed regulation system of asynchronous motor, the control of torque is more complicated. In the low frequency band, because the influence of resistance and leakage reactance cannot be overlooked, if VPf is still constant, the magnetic flux will be reduced, and then the output torque of the motor will be reduced. For this purpose, the voltage is appropriately compensated in the low frequency bands to increase torque. Generally, the inverter is manually set and compensated by the user.

3. Set the inverter to the built-in keyboard operation mode, press the run key and stop button, and check whether the motor can start and stop normally.

4. Understand the maintenance code when the inverter runs faulty, investigate the factory value of the thermal maintenance relay, investigate the set value of overload maintenance, and be able to correct it when needed. The operator of the inverter can set the function of the electronic thermal relay of the inverter according to the operation manual of the inverter. When the output current of the inverter exceeds its allowable current, the overcurrent maintenance of the inverter will block the output of the inverter. Therefore, the maximum threshold of the inverter's electronic thermal relay does not exceed the maximum allowable output current of the inverter.

3. Test run with load

1. Manually operate the operation stop button of the inverter panel, investigate the operation stop process of the motor and the display window of the inverter to see if there is any abnormal phenomenon.

2. If the inverter presents an overcurrent maintenance action during the process of starting the P abort motor, the deceleration time of P should be set from the beginning to speed up. The acceleration of the motor during acceleration and deceleration depends on the acceleration torque, while the frequency change rate of the inverter during the start and braking process is set by the user. If the moment of inertia of the motor or the load of the motor changes, when the speed is increased or decelerated according to the preset frequency change rate, the acceleration torque may not be enough, and then the motor stall will be formed, that is, the motor speed is not in harmony with the output frequency of the inverter, and then the overcurrent or overvoltage will be formed. Therefore, the acceleration and deceleration time is reasonably set according to the moment of inertia and load of the motor, so that the frequency change rate of the inverter can be harmonized with the speed change rate of the motor.
More on that
Delixi inverter selection points Delixi inverter selection points

Variable-frequency drive (VFD) is an electric power control device that uses frequency conversion skills and microelectronics skills to control and communicate motors by changing the frequency of the power supply for motor operation. The inverter is mainly composed of rectifier (communication to DC), filtering, inverter (DC to ditch) ...

Delixi inverter alarm parameter check method Delixi inverter alarm parameter check method

1. There is a problem with a frequency converter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is DC bus undervoltage. Since the control loop power supply of this type of inverter is not taken from the DC bus, but from the communication input through the transformer alone...

How to select Delixi voltage regulator How to select Delixi voltage regulator

1. For pure resistive loads such as incandescent lamps, resistance wires, electric furnaces and other equipment, the power of the voltage regulator should be 1.5 times the power of the load equipment - 2 times that of the load equipment, for example, if your electric furnace is about 250W, you can choose a voltage regulator with a power of 500W. 2. Rationality ...

Drawing precautions for wiring diagram of electrical components - Delixi Drawing precautions for wiring diagram of electrical components - Delixi

(1) The drawing of the wiring diagram and the wiring table shall be subject to the request of GB6988.6-1993 in the "Production of Control System Function Table Diagram". (2) All electrical components and wires should be marked with letter symbols and wiring numbers that differ from those in the schematic diagram of the electrical circuit. Schematic diagram catalog number, final ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

The component of the main line of the inverter - Delixi The component of the main line of the inverter - Delixi

An inverter is usually a device that replaces a constant voltage and frequency with a constant voltage or frequency for a variable voltage. However, in the application, the inverter will inevitably present shortcomings, and when analyzing the shortcomings of the problem, in order to deal with the shortcomings well and quickly, ...

Delixi voltage regulator capacity and size calculation method Delixi voltage regulator capacity and size calculation method

1. Single-phase circuit single-phase power supply - power supply with a single AC electromotive force. The fundamental power supply method for civil electricity. Single-phase load – A load that is powered by a single-phase power supply. Household appliances such as lights, televisions, and electric fans are generally single-phase loads. The accounting method is as follows: a. When negative ...

Circuit breaker control loop to reduce damage method - Delixi Circuit breaker control loop to reduce damage method - Delixi

1 Anatomy of the causes The various causes of the burning of the control loop components of the unmanned station are analyzed and classified as follows: · When the personnel on duty operate, the precautions are not well grasped or the operation is improper; · The organization does not lock and close the operation when it is not stored in energy, and the auxiliary contact of the switch cabinet ...

Reducer troubleshooting method - Delixi Reducer troubleshooting method - Delixi

01 "O" ring spell In addition to the oil seal problem of the reducer itself, the robot manufacturer will also have an impact on the planning and installation of the reducer components, due to the sealing of the reducer, in addition to the oil seal, there are also O-rings. O-rings are a very common type of product sealing planning.

Delixi circuit breaker accessory function Delixi circuit breaker accessory function

Varieties of circuit breaker accessories It is divided into two categories: in-flight accessories and out-of-flight accessories. The accessories in the machine are the subordinate equipment of the equipment inside the circuit breaker, including four types: shunt tripper, undervoltage tripper, auxiliary switch and alarm switch. Normally the in-flight accessories have to be uncovered with the device, but now ...

The difference between an isolation switch and a circuit breaker The difference between an isolation switch and a circuit breaker

The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position. Isolate ...

LDO low dropout linear regulator features - Delixi LDO low dropout linear regulator features - Delixi

Since it is used as a low dropout voltage regulator, the first feature is the extremely low input and output voltage difference, and secondly, it also has stable voltage output, low noise, small ripple, small size, and simple peripheral circuits. If an LDO regulator is used when planning the circuit, the general requirement is at least ...

Delixi low dropout linear regulator type Delixi low dropout linear regulator type

1.AC/DC the use of power supply Schematic diagram of the use of low-dropout linear regulators in AC/DC power supplies. In this circuit, the alternating current is stepped-down by the power transformer to obtain the AC low voltage, and then through the rectifier filter circuit to obtain the unstable DC voltage, and then through the low dropout linear voltage regulation.

Delixi inverter selection points Delixi inverter selection points

Variable-frequency Drive (VFD) is an electric power control equipment that uses frequency conversion skills and microelectronics skills to control and communicate motors by changing the frequency of the working power supply of the motor. The inverter is mainly composed of rectifier (communication to DC), filtering, inverter (DC to ditch) ...

Delixi inverter common problems Delixi inverter common problems

1. The pressure of Delixi inverter system is unstable and simple vibration? Answer: The pressure of the system is unstable, which may be due to the following reasons: A. There is a problem with the orientation of the pressure of the pressure sensor collection system, the pressure collection point is too close to the water pump outlet, and the pipeline pressure is affected by the water outlet ...

Voltage regulator power selection and determination - Delixi Voltage regulator power selection and determination - Delixi

1. The output power of the voltage regulator is the maximum power Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also inductive loads that start instantaneous currents.

The choice of Delixi miniature circuit breaker The choice of Delixi miniature circuit breaker

(1) Type selection. Depending on the application, select different circuit breakers. Circuit breakers are generally divided into power distribution, lighting, motor maintenance, thyristor maintenance and leakage maintenance. (2) Selection of the number of poles. It should be based on different installation environment conditions.

Introduction of molded case circuit breaker - Delixi Introduction of molded case circuit breaker - Delixi

Delixi plastic case circuit breaker is also called equipment circuit breaker, the external contact of the grounding terminal, arc extinguisher, tripper and operating organization are installed in a plastic shell. Auxiliary contacts, undervoltage trippers, parallel trippers, etc. Most of them are modular, very compact in structure, and generally do not consider maintenance ...

The matching of the inverter and the motor - Delixi The matching of the inverter and the motor - Delixi

There are three types of motor inverters ●Ordinary function type. The fundamental V/F frequency conversion speed regulation function, speed regulation accuracy and torque control function requirements are not high for general use can be satisfied. ●High function type. V/F frequency conversion speed regulation with torque control function, hoist constant ...

Delixi inverter built-in bypass soft starter CDRA-K3 Delixi inverter built-in bypass soft starter CDRA-K3

Delixi built-in bypass soft starter CDRA-K3 series is a set of soft start, soft parking and multi-functional protection in one of the motor control equipment. Realize a smooth starter motor without impact during the entire starting process. CDRA-K3 series has built-in bypass contactor and control power supply.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top