How to adjust the output voltage of Delixi voltage regulator

Create Date: 2024-8-30 12:03:23|Source: Delixi

1. How to disassemble the voltage regulator

Generally, there are screws on the shell of the voltage regulator, please disconnect the power supply first, and then remove all the screws on both sides to take off the shell.

After the regulator shell is disassembled, the circuit, copper coil, carbon brush, etc. inside will be revealed, do not touch anything at the moment, and carefully find the circuit board of the voltage regulator. Most of the voltage regulators of Delixi have adjustable modules, and some models do not have this module that can fine-tune the voltage

                              How to adjust the output voltage of Delixi voltage regulator

2. How to fine-tune the output voltage of the voltage regulator

At this point, we can first power up the voltage regulator, then find a smaller Phillips screwdriver and put it on top of the adjustable module, and then fine-tune the voltage clockwise or counterclockwise while investigating the voltmeter on the voltage regulator until we reach the voltage we want.

More on that
Precautions for the use of Delixi leakage protector Precautions for the use of Delixi leakage protector

1. If the two branch lines are connected, the current in the zero line flows to each other, which destroys the working current balance in the zero sequence current transformer and causes the leakage protector to malfunction. If you want to use the neutral line of the power branch line as the neutral line of the lighting branch line nearby, it will cause the leakage of the power branch line.

The reason for the heat and heat of the switch socket in Delixi The reason for the heat and heat of the switch socket in Delixi

1. The socket quality is low quality First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...

The main factor affecting the poor heat of the instrument - Delixi The main factor affecting the poor heat of the instrument - Delixi

The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different samples are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...

Delixi product parameter unit VF and V difference Delixi product parameter unit VF and V difference

Voltage vf and v difference: The two have different meanings, vf on the battery represents the feedback voltage, while v represents the capacity of the battery, which is the unit of measurement of voltage. Lithium battery is a kind of battery with lithium metal or lithium alloy as the positive/negative electrode data and the use of non-aqueous electrolyte solution. ...

Instrumentation overhaul method - Delixi Instrumentation overhaul method - Delixi

Contrasting method The specific method is to let the problematic meter and the normal meter operate under the same conditions, and then detect the signals at some points and compare the two sets of signals measured, if there are differences, you can conclude that the fault is here. This method requires maintenance personnel to have considerable knowledge and skills.

Delixi inverter common problems Delixi inverter common problems

1. The pressure of Delixi inverter system is unstable and simple vibration? Answer: The pressure of the system is unstable, which may be due to the following reasons: A. There is a problem with the orientation of the pressure of the pressure sensor collection system, the pressure collection point is too close to the water pump outlet, and the pipeline pressure is affected by the water outlet ...

Thermal calculation of linear regulator - Delixi Thermal calculation of linear regulator - Delixi

Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is calculated in the same way as the efficiency accounting, which is simply the value of the difference between the output input voltage and the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...

Damage and repair of internal electronic components of the inverter - Delixi Damage and repair of internal electronic components of the inverter - Delixi

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter). Middle...

Delixi low-voltage AC contactor can not be suction reason Delixi low-voltage AC contactor can not be suction reason

Although this is not a common problem of AC contactors, the inability of AC contactors to engage will affect the efficiency of the operation and even damage the production equipment.

Delixi voltage regulator working principle Delixi voltage regulator working principle

In Delixi voltage regulator, the voltage correction from and under voltage conditions is performed through two basic operations, namely Oersted and step-down operation. These operations can be switched on and off manually or automatically by electronic circuits. Under voltage conditions, the voltage of the boost operation is increased to the rated voltage.

Introduction of molded case circuit breaker - Delixi Introduction of molded case circuit breaker - Delixi

Delixi plastic case circuit breaker is also called equipment circuit breaker, the external contact of the grounding terminal, arc extinguisher, tripper and operating organization are installed in a plastic shell. Auxiliary contacts, undervoltage trippers, parallel trippers, etc. Most of them are modular, very compact in structure, and generally do not consider maintenance ...

Linear regulator and switching regulator concept - Delixi Linear regulator and switching regulator concept - Delixi

01. What is a linear voltage regulator? A linear regulator uses a transistor or FET that operates in its linear region to subtract the excess voltage from the input voltage applied to generate a conditioned output voltage. The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...

Delixi CDF1 isolation switch introduction and the difference with the transfer switch Delixi CDF1 isolation switch introduction and the difference with the transfer switch

Delixi CDF1 load isolation switch, the product material is carefully selected, with the advantages of reliability and durability. At the same time, it is locked when the power is on, and it can only be turned on when the power is off, which effectively avoids the occurrence of electric shock accidents. The contacts are made of high-quality copper ...

Delixi DZ47S wiring method Delixi DZ47S wiring method

The general leakage circuit breaker is used to wire the principle of the upper and lower lines, as long as the phase line and the zero line can be distinguished, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same. Delixi DZ47LE C40 ...

Causes the inverter breakdown factor - Delixi Causes the inverter breakdown factor - Delixi

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the inverter voltage formed due to various reasons that exceeds the rated voltage, which is reflected in the DC voltage of the inverter DC bus. The overvoltage alarm generally appears at the time of shutdown, and its main ...

Leakage protector leakage cause - Delixi Leakage protector leakage cause - Delixi

1. Poor device If the terminal posts of the leakage protector are not firmly connected during the installation, it will often lead to the heating and oxidation of the terminal post for a long time, so that the wire insulation layer will be scorched, and accompanied by the smell of ignition and rubber and plastic burning, forming an undervoltage of the line and tripping the leakage protector. ...

The type of regulated power supply - Delixi power supply The type of regulated power supply - Delixi power supply

(1) Ferromagnetic resonant communication regulator. It consists of a full choke and a corresponding capacitor, and has a constant voltage volt-ampere characteristic (AC regulated power supply). (2) Magnetic amplifier communication regulator. The magnetic amplifier and the autotransformer are connected in series, and the impedance of the magnetic amplifier is changed by electronic circuits to stabilize the output ...

Delixi product parameter unit VF and V difference Delixi product parameter unit VF and V difference

Voltage vf and v difference: The two have different meanings, vf on the battery indicates the feedback voltage, while v represents the capacity of the battery and is a unit of measurement of voltage. Lithium battery is a type of battery that uses lithium metal or lithium alloy as the positive/negative electrode material and uses a non-aqueous electrolyte solution. ​ ...

Delixi electrical components circuit breaker introduction Delixi electrical components circuit breaker introduction

What is a Circuit Breaker? What is the function of a circuit breaker? How to choose the right circuit breaker in the work? The circuit breaker is what we often call an air switch. Just like a dam that controls the release of water, when the sluice gate is opened, the flow of water is continuous, and when the sluice gate is lowered, it blocks the flow of water. ...

Resistance quantization circuit exerts resistance to the flow of current – Delixi Resistance quantization circuit exerts resistance to the flow of current – Delixi

We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). When it comes to metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal. The standard unit of resistance is ohms, there are ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top