Don't panic when you encounter a problem with the pressure sensor, you should find a way to solve it, if the pressure rises, the transmitter output will not rise.
In this case, first look at the pressure sensor pressure interface to see if it is leaking or blocked; If not, check the connection form and power supply; If the power supply is normal, just pressurize to see if the output changes, or check if there is an output at the zero position of the sensor; If there is no change, the sensor is damaged, which may be due to damage to the instrument or other parts of the system.
Problems with pressure sensor seals
The pressure transmitter output does not change, and then the pressure transmitter output changes suddenly, and the pressure release transmitter zero position cannot go back, which may be a problem with the pressure sensor seal.
The contrast between the transmitter and the pointer gauge is significant
Error is normal, just admit the normal error range; A problem that tends to occur is the effect of the device position of the differential pressure transmitter on the zero output, because the measuring range of the differential pressure transmitter is small, and the sensor element in the transmitter affects the output of the differential pressure transmitter.
The output signal of the transmitter is unstable
The problem with this kind of problem is that it is a stressor. The pressure source itself is an unstable pressure, which is likely to be due to the weak anti-interference ability of the instrument or pressure sensor, the oscillation of the sensor itself is serious, and the sensor fails;
Normally, because the standard of the sealing ring is different, the sealing ring will be pressed into the pressure inlet of the sensor after tightening, blocking the sensor, and the pressure medium cannot enter when pressurized, but when the pressure is high, the sealing ring will suddenly turn over, and the pressure sensor will change due to pressure. The way to eliminate this problem is to remove the sensor and directly see if the zero level is normal. If the zero position is normal, replace the seal and try again.
When installing, the pressure-sensitive part of the transmitter should be axially straight with the direction of gravity, and after the device is fixed, the zero position of the transmitter should be adjusted to the standard value.
|
More on that
|
The access point for load cell dashboards – ifm
Key points of maintenance of electronic crane scales, automobile weighbridges, electronic forklift scales, unique effect electronic scales, and the outer dial of Dongguan electronic weighbridge weight sensor:
The detection and analysis of problems in the application of load cells, and the common problems of the weighing appearance of automation technology have been in the end of the system software.
|
|
TCC temperature sensor won the "Red Dot Design Award 2020"
The TCC temperature sensor was unanimously recognized by the jury and won the Red Dot Design Award 2020 for its cost-effective solution with its excellent design, ideal cleaning performance and high-quality materials.
ifm TCC ...
|
|
Choice of pressure sensor – ifm
The first step in selecting a pressure sensor is to determine the pressure to be measured. Exciter sensors are divided into mechanical pressure and pneumatic pressure (hydraulic). The mechanical pressure unit is generally N.KN.KGF, etc. The pneumatic and hydraulic units are generally KPA, MPa, PSI, etc. This article describes the selection of mechanical pressures.
...
|
|
Tips for setting CAN parameters for ifm controllers
1. ifm controller CAN parameters: communication cycle
In some applications, it is possible to set the monitoring time for SYNC packets generated by the master here.
Note that this moment is larger than the SYNC moment of the master. To go through the experiment ...
|
|
Causes of bearing damage caused by ifm
Not all damaged bearings can be corrected, but the cause and extent of the damage to each damaged bearing must be evaluated to prevent or reduce further damage before considering the correction or replacement of a new bearing. There are many reasons for bearing damage, such as improper equipment, dirt invasion, etc.
|
|
Advantages of ifm RFID solutions:
ifm has the widest range of IO-Link sensors on the market. The new RFID antenna further completes the original product variety. The RFID antenna is planned to connect to the IO-Link master. The master* can supply up to 8 M12 sockets for easy connection to IO-Link RFID antennas. IO-Link Master ...
|
|
Attention points for the problem of ifm pressure sensors
Problems can arise when pressure sensors are stored or installed when exposed to manufacturing conditions that exceed the limits of the supplier's rules. Here are six factors worth noting:
1. Temperature
Excessive temperature is one of the common causes of many problems with pressure sensors, caused by ...
|
|
Force sensor applications on robots
1. Constant force
Torque sensors were first used for polishing, polishing, and other applications. Because these applications are difficult to automate, the robot needs some feeds to confirm that its drive is sufficient.
By introducing a reaction circuit into your program, you can easily implement ...
|
|
Moisture-proof method for sensors – ifm
As an accurate detection device, if the sensor is damp, it will be troublesome, the sensor will affect its accuracy and stability when it is damp, and it will form a problem if the sensor is used in a more important place, then the loss of the formation is very heavy. In '08 there was a ...
|
|
Use and maintenance of strain gauge load cells – ifm
The aluminum foil sensor is composed of elastomer, strain gauge, adhesive, maintenance layer, compensation circuit, etc. The strain transmission path is: elastomer - + adhesive → strain gauge sensitive grid - + overlay - maintenance coating, which constitutes a complex system that is more different from the strain gauge itself. If the application attached to the elastomer ...
|
|
Precision pressure sensors with additional temperature monitoring in ifm
ifm precision pressure sensors with additional temperature monitoring output via IO-Link and 2 switching channels for continuous transmission of process values and advanced diagnostic information in a housing width of only 19 mm
● 2 solutions: ...
|
|
Common faults of lambda sensors – ifm
1. Oxygen sensor poisoning.
Oxygen sensor poisoning is a common and difficult problem to prevent, especially in cars that often use leaded gasoline, and even new oxygen sensors can only operate for a few thousand kilometers. If it's just a subtle case of lead poisoning, then use a box of lead-free ...
|
|
Regulating transformer three-phase unbalance method
1. Pay attention to the reasonable distribution of three-phase load
In the distribution of three-phase loads, power operators should carefully collect and record the relevant data in the practical operation, so as to be able to guess the status of the electricity load to a certain extent.
Secondly, to be able to ...
|
|
Troubleshooting of high-frequency pressure sensors during operation
1. When the pressure goes up, the output of the transmitter can't go up.
In this case, you should first check whether the pressure connection is leaking or blocked. If you admit that it is not, check the wiring method and check the power supply, if the power supply is normal, then briefly pressurize to see if the output changes, or observe the zero position of the sensor ...
|
|
Pressure sensor interference source – ifm
We often use pressure sensors, there are pressure sensors in various environments, sometimes we will find that the pressure sensor in the use of time and time measurement is not accurate, or the signal output is unstable, which is generally disturbed by the disturbance source, the disturbance source of the pressure sensor mainly includes...
|
|
The difference between the ifm proximity switch PNP and NPN
There are two kinds of proximity switches: NPN output type (current inflow) and PNP output type (current outflow), when the current outflow sensor (PNP output type) is turned on, the current flows from the power supply to the load through the output terminal of the sensor, enters the load, and then flows to the connection.
|
|
Essentials for the selection of ifm controllers
1. The ifm controller has a control function
Another important reference feature for the purchase of ifm controllers is the ability to control movements and other applications. Fulfillment of these functional requirements requires I/O, as well as a strong processor and the ability to prioritize missions.
Programmable Drum Switches (PDS...
|
|
The main classification of current sensors is ifm
(1) Resistance shunt: It is actually a resistance with a very small resistance value, when there is a current passage period, according to Ohm's law, the voltage occurs in the resistance, and the current size is known according to the measured voltage value. The resistance shunt has high precision, fast response, low cost, simple use, and disadvantages ...
|
|
Load cell wiring method – ifm
There are four-wire and six-wire load cells. Four-wire system: EXC EXC: Power cord, that is, the DC power supply supplied by the instrument to the sensor. SIG, SIG-: The signal line, that is, the signal line output by the sensor, is output to the instrument. In addition to the above four lines, there are more than two in the four-wire system: SEN, SEN-: feedback line ...
|
|
The solution to the non-output of pressure transmitters – ifm
1. If the pressure transmitter is used in cooperation with the digital display, if the digital display does not appear at this time, then the user may say that the pressure transmitter has no output, but in fact, this problem is obvious, and it is unreasonable to hastily determine that the pressure transmitter has no output. If the pressure transmitter is working properly, ...
|
|