1. Pay attention to the reasonable distribution of three-phase load
In the distribution of three-phase loads, power operators should carefully collect and record the relevant data in the practical operation, so as to be able to guess the status of the electricity load to a certain extent.
Secondly, it is possible to achieve a better three-phase balance distribution problem by installing balancing equipment. In some low-voltage three-phase four-wire system, the reactive power compensation equipment for adjusting the unbalanced current can be added to solve the various results of the unbalanced current phenomenon in the power grid that are often presented. Such a device can not only compensate for the reactive power of the system, but also adjust the effect of unbalanced active current.
In addition, according to the different conditions of the load moment in practice, the appropriate adjustment of the wiring method also has a certain impact on the reasonable distribution of the three-phase load.
2. The management method of unbalanced current in three-phase load
According to the compensation principle of unbalanced current acceptance, at any certain time, the unbalanced load of three phases is ungrounded, and each of them can be connected in parallel with the same resistance and capacitor. Therefore, under the guidance of the theory of unbalanced current management and electric acceptance, the equivalent of different properties can be analyzed to determine the interphase and relative reactive power compensation. When the distribution transformer is to compensate for the unbalanced current, the following criteria should be met:
First, there should be two contents for the management of the demand for current, one is to compensate the power factor, and the other is to regulate the three-phase current imbalance, which together determine the reactive power required for compensation.
The second point is that in the practical construction of the project, the all-inclusive management method should be selected to distinguish it from the inductance compensation to prevent serious overcompensation.
The third point is that the demand takes into account that the load will change over time, and according to this characteristic, the amount of compensation should also be adjusted appropriately according to the change of load.
The fourth point is reflected in the limitation of the number of switching times of equipment switching and compensation equipment, and the optimization plan of the whole day should be strategically handled during the design.
In short, when setting the amount of the share conditioning system, it is necessary to consider both the limitation of the power factor and the condition of the overcompensation limit.
3. Add the detection and adjustment of three-phase load
It is also necessary to carry out regular inspections of three-phase loads. After the reasonable distribution and control of the three-phase fit, the relevant part shall set up testing operations. The balance of power can not be absolute, can only be to achieve relative balance, in the practice of testing operations, each part should be based on the national and relevant parts of the balance of the measurement index as a standard, the results of the test are professionally recorded and analyzed, the load current of each phase is regularly tested, in order to find some three-phase imbalance in time.
When potential safety hazards are found in the detection process, adjustments and modifications should be made in time. Attention should also be exercised in areas where no problems were found during the testing process. After the end of the test, it is necessary not only to collect and analyze the data, but also to respond in a timely manner. The reaction here refers primarily to adjustments based on the inferred three-phase requirements from the test results, as well as speculation about the possibility of the new technology being used in the three-phase. After reasonable testing and in-depth analysis of the test results, we can prevent the appearance of imbalance to a greater extent and reduce the appearance of electricity accidents.
|
More on that
|
The difference between a fiber optic sensor and a photoelectric sensor – ifm
The first point is that photoelectric sensors and fiber optic sensors work differently
First of all, from the principle of operation of the two, first of all, the photoelectric sensor is operated according to the principle of the photoelectric effect, that is to say, when the light hits the photoelectric sensor made of semiconductors, the light will be announced.
|
|
The ifm identification system has an RFID antenna with IO-Link
Sensitive parameterization, diagnostics and data processing of ifm sensors are suitable for many different uses9 versions, suitable for a variety of different types of sensitive parameterization, diagnostics and data processing with I/O-Link Ideal for the identification of small data volumes with LR DEVICE or IO-L ...
|
|
Selection rules for pressure transmitters
Pressure transmitter is the most commonly used sensor in industrial practice, which is widely used in various industrial automatic control environments, touching water conservancy and hydropower, railway transportation, intelligent buildings, production automation, aerospace, military industry, petrochemical, oil wells, electric power, ships, machine tools, pipelines and many other occupations. ...
|
|
Considerations for choosing a temperature sensor – ifm
1. Whether the temperature of the measured target needs to be recorded, alarmed and automatically controlled, and whether it needs to be measured and transmitted at a distance;
2. The size and accuracy requirements of the temperature measurement scale;
3. Whether the size of the temperature measuring element is appropriate;
4. In the measured ...
|
|
Failure analysis of the ifm pressure sensor PN2071
1. ifm sensor PN2071 pressure up, sensor output can not go up in this case, first should check whether the pressure interface is leaking or blocked, if you admit that it is not, check the wiring method and check the power supply, if the power supply is normal, then simply pressurize to see if the output changes, maybe observe ...
|
|
Common faults of pressure sensors – ifm
The pressure sensor is still widely used in this world, but it is still a metal product after all, and it will fail after a long time.
1. Sealing problems of pressure transmitters
Initial pressurization, the output of the transmitter ...
|
|
How to use load cells and amplifiers – ifm
1. Wiring according to wiring requirements
2. Connect the specified size DC power supply to the transmitter.
3. Connect the sensor and adjust it to the corresponding zero output value (the corresponding zero output value (e.g. 0-10V output.
...
|
|
ifm OGD580 parameter settings
First, press the [Acknowledge] button to enter the first-level menu, press the [Up] or [Down] button to find the menu you want to set, and press the [Acknowledge] button to enter the set value, and the current set value will be displayed at this moment. Press and hold the [Up] or [Down] button, when the value starts to flash, keep pressing to adjust it.
|
|
Six-wire and four-wire wiring of load cells
Because the load cell has the advantages of high measurement accuracy, good temperature characteristics, and stable operation, it is widely used in the dynamic and static measurement of various structures and the primary appearance of various electronic scales.
The load cell can be selected with two different input and output wiring methods: one is ...
|
|
Notes on Linear Position Sensors – ifm
1. If the electronic ruler has been used for a long time, and the seal is now aging, it is mixed with a lot of impurities, and the water mixture and oil will seriously affect the contact resistance of the brush, which will make the displayed numbers constantly beat. At this time it can be said that the electronics of the linear displacement sensor ...
|
|
Parameter settings for the ifm sensor OGD580
First, press the [Acknowledge] button to enter the first-level menu, press the [Up] or [Down] button to find the menu you want to set, and press the [Acknowledge] button to enter the set value, which will be displayed at this moment. Long press the [Up] or [Down] button, when the value starts flashing, continue to press to adjust the ...
|
|
The cause of sensor interference – ifm
1. The PCB layout board touches the problem, and when the imitation signal is traced, the imitation signal is not wrapped with imitation, and there is even a possibility that the signal line is directly taken to the power line, which is easy to receive disturbance.
Solution: When it is a board, wrap the GND to imitate the signal line. If there is a model ...
|
|
Everyday attention to ifm pressure transmitters
1. Measurement scale: The normal use of the pressure transmitter should not exceed its measurement scale and working condition scale, and the short-term overload is allowed to be 120%.
2. Working environment: The working environment of Germany IFM pressure transmitter should be free of strong corrosion ...
|
|
Pressure sensor type PN for industrial applications with display – ifm
ifm pressure sensors PN for industrial use:
The first is consolidation: an ambition measuring element suitable for various pressure scales;
The second red-green scale: according to the color of the display, you can quickly identify the "good scale" or switch ...
|
|
Classification of ifm temperature sensors
According to the measurement method, it can be divided into two categories: touch type and non-touch type.
1. Touch type
The detection part of the touch temperature sensor has an outstanding touch with the measured target, also known as a thermometer.
The thermometer reaches thermal equilibrium by conduction or convection, so that the thermometer indication ...
|
|
Presentation of the performance of the S-type load cell – ifm
1. S-type load cells are moderately priced and suitable for mass production - good sensor consistency is required, suitable for automated batch production, and high requirements for processing equipment to eliminate inconsistencies and faults formed by manual operation.
2 ...
|
|
How to care for ifm sensors
1. When measuring the liquid pressure, in order to prevent the sensor from being damaged by overpressure, the device position of the sensor should prevent the impact of the liquid.
2. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer pipe.
3. The impulse pipe should be installed in a place where the temperature fluctuation is small.
...
|
|
The main feature of the wireless sensor network is the ifm sensor
(1) Large-scale
In order to obtain accurate information, many sensor nodes are usually arranged in the monitoring area, perhaps in the tens of thousands, or even more. The large-scale nature of the sensor network contains two implications: on the one hand, the sensor nodes are distributed in a large geographic area, such as in the original ...
|
|
Position sensor key terms
Incremental sensors
Only the bearing change information is provided so that the practice bearing is unknown at startup. Each time the index/symbol signal is used to say the zero or zero bit of the device. Detected in the homing procedure. For the commutation of brushless motors, the motors usually have three magnetic Hall sensors, which are ...
|
|
Correct installation of pressure sensors – ifm
Generally, the damage of the high-temperature melt pressure sensor is caused by the improper orientation of the device, if the sensor is forcibly installed in a hole that is too small or an irregularly shaped hole, it may cause the vibration film of the sensor to be damaged by impact, choose the appropriate thing to process the device hole, ...
|
|