The first step in selecting a pressure sensor is to determine the pressure to be measured. Exciter sensors are divided into mechanical pressure and pneumatic pressure (hydraulic). The mechanical pressure unit is generally N.KN.KGF, etc. The pneumatic and hydraulic units are generally KPA, MPa, PSI, etc. This article describes the selection of mechanical pressures.
1. For mechanical pressure, the first thing to consider is whether it is pressure measurement or tensile force measurement. If you only measure pressure, you can choose a pressure measurement sensor. If you need to measure the tensile force, you need to select a tensile pressure sensor. In addition, if you need to connect something or pressure head, it is best to choose a tension pressure sensor to make it easier for things to remove. The author has seen a case before. The customer selects a pressure measurement sensor. The pressure sensor is pressed down. First, press it into something and continue to press down until you reach the product.
In this way, the force sensor is subjected to a force first, and then the product is subjected to a force, the excitation sensor and the product are subjected to different forces, and the force on the product itself is less than that of the pressure sensor, and when the structure is now determined, the customer can only add a compensation value in the PLC program. In this case, if a pressure sensor is selected, it can completely prevent the sensor from being connected to something at the beginning.
2. In order to prevent overload damage to the sensor, load damage sensor, the range should be as large as possible. If it is driven by a pneumatic cylinder or pneumatic cylinder, the maximum thrust of the cylinder or cylinder, including the impact force, should be calculated.
3. Pick the shape and size of the pressure sensor. If there is no space constraint on the installation, a slightly larger sensor can be selected. There are generally threaded holes at the bottom of large sensors, which are convenient for installation and can be fixed directly with screws, saving the trouble of adding things. In addition, in general, slightly larger sensors are relatively accurate.
4. The ambient temperature has a certain influence on the operation of the sensor. When selecting a pressure sensor, the temperature factor should also be considered. If the ambient temperature is too high, explain to the manufacturer how to select a high-temperature sensor.
5. Since the pressure sensor outputs a millivolt signal, the signal is not a standard analog signal, so it should be equipped with a transmitter, also known as an amplifier, to convert the signal into a standard analog signal or a digital signal, such as a standard analog 4-20ma.0-5V.0-10V, digital RS232.RS485, etc.
|
More on that
|
ifm ifm sensors detect objects contactlessly
Capacitive ifm sensors have many applications in everyday life. It is capable of viewing non-metallic materials as well as detecting objects in a non-contact manner.
Capacitive ifm sensors are resistant to interference. When an object is detected, the small ...
|
|
ifm halogen-free and silicone-free Y-connection cables
Y-shaped distributor for connecting two sensors or with built-in logic AND or OR for hygienic and wet areas
· Halogen-free and silicone-free
· Angled nuts with enhanced grip help optimize sealing, even when manually screwed ...
|
|
Precautions for the selection of level transmitters – ifm
The differential pressure transmitter is a transmitter that measures the pressure difference between the two ends of the transmitter, and outputs a standard signal (such as 4-20mA, 1-5V). The difference between the differential pressure transmitter and the general pressure transmitter is that they have 2 pressure interfaces, and the differential pressure transmitter is generally divided into positive pressure end and negative pressure end.
|
|
Failure analysis and definition of ifm vortex flowmeters
Vortex flowmeter series instrument because of the use of the environment is special or harsh in the field work sometimes present such and such problems, resulting in production will be affected, vortex flowmeter and orifice flowmeter and V-cone flowmeter are different, as far as the orifice flowmeter is concerned, it is the standard orifice plate and multi-parameter ...
|
|
Quality monitoring via the Y-link of ifm
Through selective data collection on your machine, you are able to increase the overall power of your machine. DISPLAYS THE ACTUAL VALUE OF THE DEVICE'S PERFORMANCE AND HAS BEEN OPTIMIZED BY THE LINERECORDER MODULE MDE.
Possibility of use:
...
|
|
Sensor installation requirements and precautions – ifm sensors
1. Device requirements:
1. Measure the shaft diameter and center height of the high-precision displacement sensor.
2. Two sets of couplings are used to connect the device with high-precision displacement sensor between the power source and the load.
3. The sensor can be connected with a rigid or elastic coupling. The sensation is more ...
|
|
Presentation of the performance of the S-type load cell – ifm
1. S-type load cells are moderately priced and suitable for mass production - good sensor consistency is required, suitable for automated batch production, and high requirements for processing equipment to eliminate inconsistencies and faults formed by manual operation.
2 ...
|
|
Select the appropriate mounting holes for ifm sensors
ifm sensors have a lot of precautions at the time of installation, and it is necessary to pay attention to the orientation of the device, if the device orientation is not suitable, it will also form damage to the pressure sensor.
ifm sensors are required to be checked at the time and time of the device.
|
|
The main functions of IFM ifm proximity switches
1. Inspection interval
Detect the stop, start and orientation of elevators and lifting equipment; Detect the orientation of the vehicle to prevent two objects from colliding; Detect the setting orientation of the operating machinery and the limit orientation of the moving machine or components; Detect the abort azimuth of the rotary body, the opening or closing of the valve; Detection of pneumatic or hydraulic cylinders ...
|
|
The access point for load cell dashboards – ifm
Key points of maintenance of electronic crane scales, automobile weighbridges, electronic forklift scales, unique effect electronic scales, and the outer dial of Dongguan electronic weighbridge weight sensor:
The detection and analysis of problems in the application of load cells, and the common problems of the weighing appearance of automation technology have been in the end of the system software.
|
|
Advantages of IFM controllers:
1. The programming method of the programmable ifm controller is simple and easy to learn
Programmable ifm controller ladder diagram is the programming language of the more used PLC, its circuit symbols and expressions are similar to the schematic diagram of relay circuits, the ladder diagram language is intuitive, easy to learn and understand, understand the relay ...
|
|
ifm wins three iF Design Awards 2020
The IF Design Award is held annually in Hannover, organized by iF Design GmbH, the world's oldest independent design agency.
In 2020, 3 ifm products stood out from many competitors and won ...
|
|
Introduction to sensor design tips – ifm
1. Start with the bus east and west
As a first step, the engineer should take the approach of first interfacing the sensor, which is through a bus stuff to constrain the ignorance. A bus thing connects to a personal computer (PC) and then to the sensor for I2C, SPI or other ...
|
|
General knowledge of controlled systems for ifm controllers
Principles of the control system of IFM controllers:
The IFM ifm controller is a process that continues to detect the unit to be manipulated (control variable x) and compares it with the reference variable w, and according to the results of the comparison, the control variable is affected to get used to the reference variant. In most cases, ...
|
|
The main classification of current sensors is ifm
(1) Resistance shunt: It is actually a resistance with a very small resistance value, when there is a current passage period, according to Ohm's law, the voltage occurs in the resistance, and the current size is known according to the measured voltage value. The resistance shunt has high precision, fast response, low cost, simple use, and disadvantages ...
|
|
The main functions of the ifm proximity switch:
1. Inspection distance
Detect the stop, start and orientation of elevators and lifting equipment; Detect the orientation of the vehicle to avoid collision between two objects; Detect the setting orientation of the operating machinery and the limit orientation of the moving machine or components; Detect the abort azimuth of the rotary body, the opening or closing of the valve; Detection of cylinders or hydraulic ...
|
|
ifm flow sensor solutions
ifm flow sensor solutions. IFM Flow Sensor SV5200, Vortex Flow Sensor with User Friendly Display, Circuit Connection Can Be Rotated for Optimal Arrangement, With Switching Output or Frequency Output, and IO-Link for Reliable Flow Detection ...
|
|
Everyday attention to ifm pressure transmitters
1. Measurement scale: The normal use of the pressure transmitter should not exceed its measurement scale and working condition scale, and the short-term overload is allowed to be 120%.
2. Working environment: The working environment of Germany IFM pressure transmitter should be free of strong corrosion ...
|
|
Features and benefits of fiber optic sensors
Fiber optic sensors have the advantages of extremely high sensitivity and accuracy, good inherent safety, anti-electromagnetic interference, high dielectric strength, corrosion resistance, integration of sensing and transmission, and compatibility with digital communication systems.
High sensitivity
...
|
|
Use and maintenance of strain gauge load cells – ifm
The aluminum foil sensor is composed of elastomer, strain gauge, adhesive, maintenance layer, compensation circuit, etc. The strain transmission path is: elastomer - + adhesive → strain gauge sensitive grid - + overlay - maintenance coating, which constitutes a complex system that is more different from the strain gauge itself. If the application attached to the elastomer ...
|
|