Yaskawa servo zone brake alarm 410 fault analysis

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

1. The input power supply of the drive drops, resulting in an internal undervoltage alarm.

2. The drive power supply failure causes the safety zone dynamic to detect the undervoltage fault.

3. The servo unit fuse blows.

4. Servo unit failure leads to undervoltage failure.

5. Servo zone dynamic detection circuit fault false alarm undervoltage.
Yaskawa servo zone brake alarm 410 fault analysis

More on that
Yaskawa inverter wiring attention Yaskawa inverter wiring attention

Attention to the wiring of the inverter 1. The inverter itself has strong electromagnetic interference, which will interfere with the work of some equipment, so we can add a cable sleeve to the output cable of the inverter. 2. The control line in the inverter or control cabinet is at least 100mm away from the power cable, etc. ...

How to cancel the Yaskawa robot collision alarm? How to cancel the Yaskawa robot collision alarm?

1. Enter the management mode and click on the robot. 2. Click on the collision detection level, enter the designated page, select the collision detection file number, enter 9, and press enter. 3. Change the function from valid to invalid. After the robot action is restored, it can be changed back to effective. ...

Yaskawa H1000 inverter overload oL2 fault Yaskawa H1000 inverter overload oL2 fault

There are two types of inverter overload faults: 1. If there is a problem with the load, it is a problem with the motor, such as the lack of oil in the bearing, the damage to the bearing, the burning of the winding, etc., and there is a situation that the power of the motor is small, and it is more difficult to drag the load. 2. It is the inverter ...

Yaskawa Robotics - the main functions and components of industrial robot controllers Yaskawa Robotics - the main functions and components of industrial robot controllers

The main functions of the industrial robot controller The controller mainly solves the forward kinematics and inverse kinematics of the robot to help the robot complete the trajectory planning. The controller of the industrial robot is composed of controller hardware and controller software.

Yaskawa servo motor reversal parameter setting method Yaskawa servo motor reversal parameter setting method

1. Open the parameter setting interface of the servo drive and find the invert parameter setting option. 2. Set the inversion parameters, including the inversion voltage, inversion speed, etc. Depending on the specific situation, the reversal voltage can be set to -10V and the reversal speed to 1000RPM. 3. After saving the settings ...

Yaskawa manipulator use specification Yaskawa manipulator use specification

Yaskawa manipulator specification It must be trained before the job and can only be operated after qualifying. Untrained personnel are not allowed to operate the manipulator. BEFORE OPENING, CHECK WHETHER THE AIR SOURCE OF THE MANIPULATOR IS ENERGIZED, ADJUST THE AIR PRESSURE OF THE PRESSURE VALVE BETWEEN 0.6MPA AND 0.8MPA, AND CHECK WHETHER THE VOLTAGE IS NORMAL. What is ...

Yaskawa made its debut at the AMB - Robotics Innovation Trade Fair Yaskawa made its debut at the AMB - Robotics Innovation Trade Fair

As a long-standing and reliable supplier of automated metalworking solutions, Yaskawa will be exhibiting at AMB for the first time. Possible applications for the company's Motoman robots include tool handling, machining and stacking workpieces, and machine loading. At booth 6D50 in Hall 6, ...

What could be the cause of the CF failure of Yaskawa inverter? What could be the cause of the CF failure of Yaskawa inverter?

The fault code is CF refers to Control Failure, which reaches the torque limit for more than 3 seconds in the deceleration stop (no PG vector control mode) Possible reasons are: The motor parameters are not set correctly The set value of the torque limit is too small The load inertia is relatively ...

Features of Yaskawa YASKAWA inverter CH700 series Features of Yaskawa YASKAWA inverter CH700 series

Yaskawa YASKAWA inverter CH700 series is a product optimized for cranes with the product concept of versatility, ease of use, and peace of mind. Utilizing advanced technologies such as brake sequencing that incorporate 30 years of experience, we provide answers to a wide range of issues related to crane operation.   Yaskawa Y ...

Yaskawa MOTOMAN servo drive fault repair case summary (1-2) Yaskawa MOTOMAN servo drive fault repair case summary (1-2)

1. The motor runs faster in one direction than in the other; (1) Cause of failure: The phase of the brushless motor is wrong. Solution: Detect or detect the correct phase. (2) Cause of failure: When not used for testing, the test/deviation switch hits the test position ...

Yaskawa servo drive fault code and handling method Yaskawa servo drive fault code and handling method

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

Robotics propelled Yaskawa Electric to record profits Robotics propelled Yaskawa Electric to record profits

Yaskawa Electric, one of the world's largest manufacturers of industrial robots, announced a 150% year-on-year increase in net profit for the six months ended Sept. 30. The Japan company announced that the company reported a profit for the quarter due to the demand for its industrial robots in China, Japan and United States.

How to set the number of fault retries on Yaskawa servo How to set the number of fault retries on Yaskawa servo

Set it in the controller's parameter settings. 1. Connect the computer and the controller to enter the parameter setting interface. 2. Find the parameters of the number of servo fault retries or FaultRetryCount. 3. Set it to the required number of retries, which is usually recommended to be set to 1— ...

Common faults of Yaskawa inverters Common faults of Yaskawa inverters

The switching power supply is damaged Switching power supply damage is the most common fault of many inverters, usually caused by short circuit in the load of switching power supply, in the design of switching power supply circuits of many inverters, Yaskawa inverter is relatively successful. OH failure Old...

Yaskawa Robotics - Introduction to the characteristics of robot dresspacks Yaskawa Robotics - Introduction to the characteristics of robot dresspacks

1. Long service life: high-quality dresspack effectively prolongs the service life of the equipment due to the optimization of the sheath material and the expansion device of the dresspack; 2. Easy to replace: In the event of an emergency with internal pipeline damage, the dresspack can be easily replaced without damaging the original sheath and cable joints.

The cause and treatment method of Yaskawa servo drive alarm code B32 The cause and treatment method of Yaskawa servo drive alarm code B32

Fault description: Current detection fault 2 Cause: V-phase current detection loop fault Solution: When the power is turned on again and the alarm still occurs, it may be a servo unit failure. Replace the servo unit. Here's how to solve it The supply voltage exceeds the specification range ...

Yaskawa Servo Motor – The difference between a servo motor and a stepper motor Yaskawa Servo Motor – The difference between a servo motor and a stepper motor

1. Different control methods Stepper motor: The rotation angle is controlled by controlling the number of pulses, and one pulse corresponds to one step angle. Servo motor: The angle of rotation is controlled by controlling the length of the pulse time. 2. The workflow is different Stepper Motor: Stepper ...

Wiring method of Yaskawa A1000 inverter Wiring method of Yaskawa A1000 inverter

First, the wiring of the main circuit 1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, the fragmented wires must be cleaned, and the fragmented wires may cause abnormalities. ...

Yaskawa inverter – the future of high-voltage inverters Yaskawa inverter – the future of high-voltage inverters

1. High-voltage inverter will develop in the direction of high power, miniaturization and lightweight. 2. The high-voltage inverter will develop in the direction of direct device high voltage and multiple superposition (device series and unit series). 3. New power semiconductors with higher voltage and higher current ...

Analysis of the causes of Yaskawa servo drive alarm code 040 Analysis of the causes of Yaskawa servo drive alarm code 040

1. It may be that the capacity of the servo unit does not match the capacity of the servo motor. 2. It may be that the servo unit is faulty. 3. It may be outside the range of parameter settings. 4. It may be that the set value of the electronic gear ratio is outside the set range. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top