Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.), in order to complete the control or maintenance mission.

                               Delixi relay maintenance method

1. Overhaul of sensing tissues

In the case of electromagnetic (voltage, current, center) relays, the sensing structure is the electromagnetic system. The problems of the electromagnetic system are mainly concentrated in the coil and the moving and static iron cores

(1) Coil problem: maintenance coil so usually there is coil insulation damage, mechanical injury constitutes a short circuit or grounding between the paintings, because the power supply voltage is too low, the dynamic and static iron core touch is not tight, so that the current through the coil is too large, and the coil is heated and burned. When repairing, the coil should be rewound. If the armature does not engage after the coil is energized, it may be that the connection of the coil lead wire falls and the coil is broken. Look out for the drop and weld it after

(2) Repair of core problems

The main problem of the iron core is that the armature cannot be sucked after the power is on. This may be due to broken coils, foreign matter between the moving and static cores, and low power supply voltage. It should be patched on a case-by-case basis.

After the angular electricity, the armature peak is loud. This may be due to uneven touch surfaces of moving and static irons, or oil contamination. When repairing, the coil should be removed, and if there is oil stain on the touch surface of the flat or flat level, it should be cleaned

The noise may be caused by short circuits and ring breaks, and it is sufficient to repair or replace a new short circuit ring.

After the power is off, the street subway cannot be released immediately, which may be caused by the fact that the moving iron school is stuck, the size of the core and the barrier, the elastic strain, and the oil stain on the touch surface of the core. DURING THE MAINTENANCE, IT SHOULD BE TREATED DIFFERENTLY ACCORDING TO THE REASONS OF THE OLD ROAD, OR ADJUST THE GAS YARD TO MAINTAIN IT AT 0.020.05MM, OR REPLACE IT, OR CLEAN THE OIL STAIN WITH GASOLINE. Regarding thermal relays, the sensing tissue is a thermal element, and its common problem is that the thermal element is bad, or the thermal element malfunctions and does not function.

(1) Burning out of the thermal element. This may be due to a short circuit on the load side, or a high frequency of action of the thermal element. The heating element should be replaced and the setting value should be readjusted during maintenance.

(2) Malfunction of the thermal element. This may be due to the setting value is too small, the action is not overloaded, or the application of the occasion has a strong shock and vibration, so that the action tissue loosens and trips, resulting in maloperation

(3) The thermal element does not operate. This may be due to the setting value being too small, which makes the thermal element lose its overload maintenance function. During maintenance, the setting current should be adjusted according to the load working current.

More on that
Delixi inverter operation mode Delixi inverter operation mode

1. The inverter runs with the motor at no load 1. To set the power and number of poles of the motor, the operating current of the inverter should be considered. 2. Set the maximum output frequency, fundamental frequency, and torque characteristics of the inverter. The general-purpose inverter is equipped with a number of VPf curves for users to choose.

Delixi inverter load type Delixi inverter load type

The correct choice of Delixi inverter is very critical to the normal operation of the control system. When selecting a frequency converter, it is necessary to fully understand the load characteristics driven by the frequency converter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan, water pump ...

The general principle of circuit breaker selection - Delixi The general principle of circuit breaker selection - Delixi

(1) The additional operating voltage of the circuit breaker ≥ the additional voltage of the line. (2) The additional current of the circuit breaker ≥ the line load current. (3) The additional short-circuit of the circuit breaker can be turned on and off to ≥ the maximum shortness that may be present in the line.

Hu Chengzhong, director of Delixi, suggested five major suggestions to optimize science and technology to benefit people's livelihood Hu Chengzhong, director of Delixi, suggested five major suggestions to optimize science and technology to benefit people's livelihood

Founded in 1984, Delixi Group started with thermal relays, 36 years of big waves, has been in the first camp of China's electrical industry for many years, and has been ranked among the top 500 Chinese enterprises for 18 consecutive years. In recent years, under the guidance of the strategy of "manufacturing power", Delixi has focused on the main line of high-end manufacturing, and has taken multiple measures to ...

Delixi occasion to choose the inverter Delixi occasion to choose the inverter

We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter. When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a reference. Secondly, the output of the inverter should be fully considered ...

Changes in the control mode of the inverter - Delixi inverter Changes in the control mode of the inverter - Delixi inverter

In the process of practical speed regulation, an ordinary AC power supply with adjustable frequency can not meet the requirements of speed regulation and control of asynchronous motors, and must also take into account the effective use of the motor magnetic field, the pressing starting current and the desired torque characteristics, such as low-frequency torque characteristics.

Delixi CDM molded case circuit breaker upgrade Delixi CDM molded case circuit breaker upgrade

The 6 series electronic molded case circuit breaker CDM6Ei was launched in 2017 with the addition of a 1600A shell frame; High through-off capacity, *** high Ics=65kA, to meet specific application occasions; Long-distance four-remote communication to complete intelligent connectivity; Support mobile APP communication and alarm non-tripping function; The maximum operating temperature of the product can be ...

Thermal calculation of linear regulator - Delixi Thermal calculation of linear regulator - Delixi

Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is calculated in the same way as the efficiency accounting, which is simply the value of the difference between the output input voltage and the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...

Delixi time control switch KGL1 latitude and longitude technical parameters Delixi time control switch KGL1 latitude and longitude technical parameters

Delixi Electric KGL1 latitude and longitude time control switch is suitable for communication 50Hz operating voltage 380V and the following control circuits, Delixi time control switch, according to the local latitude and longitude, according to the season to change the automatic adjustment control time, as the timing of the implementation of components. Plugging in or out of all sorts of ...

Delixi responds to the national strategy to enter the field of high-end production Delixi responds to the national strategy to enter the field of high-end production

Electrical manufacturing is the main business and the old bank of Delixi, in recent years, the group has vigorously implemented the high-quality transformation and development strategy, and has always adhered to the intelligent manufacturing as a new engine to enhance the benefits per mu, with the construction of intelligent factories as the carrier, with the key manufacturing links as the core, and constantly increase scientific research ...

Resistance quantization circuit exerts resistance to the flow of current – Delixi Resistance quantization circuit exerts resistance to the flow of current – Delixi

We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). When it comes to metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal. The standard unit of resistance is ohms, there are ...

Choose the right inverter method - Delixi Choose the right inverter method - Delixi

The type of inverter is selected according to the type of production machinery, speed regulation range, static speed accuracy, and starting torque requirements, and it is most appropriate to decide which inverter is the most suitable to use. The so-called suitability is not only easy to use, but also economical, to meet the basic conditions and requirements of technology and production. ...

A brief introduction to Delixi leakage circuit breaker A brief introduction to Delixi leakage circuit breaker

Delixi leakage maintainer is mainly when the electrical equipment leakage problem to provide maintenance of the device, when the installation of leakage maintainer, should be other devices overcurrent maintenance device. When the fuse is used for short-circuit maintenance, the selection of its standard should be compatible with the on-off of the leakage maintainer. Appear...

Instrumentation overhaul method - Delixi Instrumentation overhaul method - Delixi

Contrasting method The specific method is to let the problematic meter and the normal meter operate under the same conditions, and then detect the signals at some points and compare the two sets of signals measured, if there are differences, you can conclude that the fault is here. This method requires maintenance personnel to have considerable knowledge and skills.

A brief introduction to three-phase transformer - Delixi A brief introduction to three-phase transformer - Delixi

All large AC power blocks are connected by a three-phase transformer for transmission and distribution at high voltage levels. Single-phase transformers can be electrically connected to form a three-phase transformer bank in a distribution system. But the standard is to combine a single phase coil into a three-phase transformer unit on a common core ...

The type of regulated power supply - Delixi power supply The type of regulated power supply - Delixi power supply

(1) Ferromagnetic resonant communication regulator. It consists of a full choke and a corresponding capacitor, and has a constant voltage volt-ampere characteristic (AC regulated power supply). (2) Magnetic amplifier communication regulator. The magnetic amplifier and the autotransformer are connected in series, and the impedance of the magnetic amplifier is changed by electronic circuits to stabilize the output ...

What are the main series of Delixi switches What are the main series of Delixi switches

1. The aesthetic slab adopts frameless large buttons and fluorescent grid planning, giving people a comfortable texture experience. The large-pitch flat panel is simple and useful, and is available in four colours: Funky White, Champagne Gold, Starlight Silver and Midnight Black. 2 ...

Delixi circuit breaker left zero right fire meaning Delixi circuit breaker left zero right fire meaning

The so-called "left zero and right fire of the circuit breaker" is nothing more than the order of the sockets - when facing the socket, the socket on the left is the neutral line, the socket on the right is the front, and that's it. Delixi socket wiring may not be "left zero right fire". ...

Delixi inverter control motor problem Delixi inverter control motor problem

Question: Delixi inverter control motor contactor does not start when there is no action? Solution: First check the output status of the controller reflected by the controller panel, and you can compare the 7 units on the panel described in the controller description book.

Delixi leakage protector protection Delixi leakage protector protection

1. Under what circumstances does the leakage maintainer not maintain the electric shock? The leakage switch models commonly used in general families are 1P+N and 2P, as far as the leakage maintainer of 1P+N and the leakage maintainer of 2P (single-phase electricity maintenance) are concerned, when people touch the zero line and the front together, people are touched.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top