Delixi E series inverter common fault analysis

Create Date: 2024-8-30 12:03:23|Source: Delixi

Fault phenomenon, fault description, detailed description of troubleshooting measures

No display at power-on, no display, no display

Check whether the power wiring is correct; Check whether the 5V power supply is normal;

Check whether the keyboard is in good contact with the control board; Check whether the control panel and keyboard are normal.

If you are using a keyboard extension cable, please check that the extension cable is made correctly and that it is in good contact

                               Delixi E series inverter common fault analysis

  Err-01

Overcurrent at constant speed

When the inverter is running at constant speed, the output current exceeds the overcurrent value to check whether the output circuit of the inverter is short-circuited, grounded or too long; Check whether the input voltage is low;

Check the load for mutations;

Carry out parameter identification or improve low-frequency torque compensation, and check whether the rated power of the motor or inverter is large enough;

  Err-O2

Overcurrent in acceleration

When the inverter is running at a deceleration, the output current exceeds the overcurrent value to check whether the motor and the line are short-circuited, grounded or too long; Check whether the input voltage is low;

Extended acceleration time;

Perform parameter identification or improve low-frequency torque compensation or adjust V/F curve; Check the load for mutations;

Check whether you choose to track the speed or wait for the motor to stop before starting; Check whether the rated power of the motor or inverter is large enough;

More on that
Delixi voltage regulator fault performance and elimination Delixi voltage regulator fault performance and elimination

Regulator problem 1: The regulator cannot be started Reason: Whether the phase sequence of the input power cord has been changed, and the air switch in the machine is not turned on or broken. Repair methods: 1. Swap the two power supply wires arbitrarily or check whether the power supply line is correct; 2. Close or replace the switch. Voltage Regulator ...

The principle and operation method of Delixi inverter operation The principle and operation method of Delixi inverter operation

  The principle and operation method of Delixi inverter: 1. No-load energizing test of inverter 1. Ground the grounding terminal of the inverter. 2. Pass the power input terminal of the inverter through the leakage maintenance switch.

Causes and solutions for circuit breaker closing failure - Delixi circuit breaker Causes and solutions for circuit breaker closing failure - Delixi circuit breaker

1. Failure analysis. 1) Closing fuse, control fuse blowing or poor contact. 2) Poor contact of DC contactor or poor contact of control switch contact and auxiliary contact of circuit breaker. 3) The DC voltage is too low. 4) Closing and locking action. ...

Delixi inverter installation and wiring Delixi inverter installation and wiring

1. The device of the inverter 1.1 The device environment requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions requiring no direct sunlight, no corrosive gas and flammable gas, less dust, ...

Delixi control transformer structure type Delixi control transformer structure type

Delixi's control transformer is one of the products used in many equipment, the type of Delixi transformer is divided into: BK, JBK, BKC, JMB, BJZ, DG, BZ and other series of control lighting transformers, with excellent performance, reliable work, wide applicability and other characteristics, generally used in machine tools, mechanical ...

The difference between linear regulator and switching regulator - Delixi The difference between linear regulator and switching regulator - Delixi

The switching voltage regulator is a different kind of regulated power supply from the linear voltage regulator, and its circuit types mainly include single-ended flyback, single-ended forward, half-bridge, push-pull and full-bridge. The difference between it and the linear power supply is that the transformer in the circuit does not work at the power frequency, but at the power frequency.

Delixi three-phase circuit breaker classification Delixi three-phase circuit breaker classification

Delixi's three-phase circuit breaker is generally divided into three types, namely 3P, 3P+N and 4P. (1) Differences: 3P: Pure three-phase electrical equipment only uses three wirings, and in the case of no single-phase load, it trips when it is short circuited to ground or phase; Otherwise, when a one-phase N-line load is generated, the N-line is disconnected ...

Damage and repair of internal electronic components of the inverter - Delixi Damage and repair of internal electronic components of the inverter - Delixi

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter). Middle...

Delixi fan and pump load frequency conversion selection Delixi fan and pump load frequency conversion selection

Delixi general fan, pump, the requirements for the inverter are simple, only the inverter capacity is equal to the motor capacity. Roots blowers, deep-water pumps, sediment pumps, and fast-changing musical fountains are available in a larger capacity. Lifting...

The choice of circuit breaker for motor protection - Delixi The choice of circuit breaker for motor protection - Delixi

Class I refers to the circuit breaker, which is only used for maintenance and not for normal operation; The other is that circuit breakers are required together for maintenance and infrequent operation. In the latter case, the operating conditions and electrical life should be taken into account. The selection principles for circuit breakers for motor maintenance are as follows: ...

Delixi inverter alarm parameter check method Delixi inverter alarm parameter check method

1. There is a problem with a frequency converter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is DC bus undervoltage. Since the control loop power supply of this type of inverter is not taken from the DC bus, but from the communication input through the transformer alone...

The reason for the failure of the inverter - Delixi The reason for the failure of the inverter - Delixi

1. Ability to adapt to the environment When the motor on the bus starts in a group, when the bus is the largest motor unit starts, the impact on the operation of the inverter, which is related to the input voltage fluctuation scale parameters promised by the inverter, for thermal power units should ensure that the bus voltage drops by 30% when the frequency conversion ...

Delixi rangefinder analysis Delixi rangefinder analysis

Delixi Group focuses on low-voltage power distribution and industrial automation in the field of comprehensive solutions suppliers, founded in 1984, is a collection of industrial operations, brand operations, capital operations as one of the large enterprise groups, for 18 consecutive years ranked among the top 500 Chinese enterprises. Delixi rangefinder is designed for ...

Delixi voltage regulator in the case of no load stable work? Delixi voltage regulator in the case of no load stable work?

Most modern LDOs and switching regulators operate reliably under no-load conditions, and some older power devices require a minimum load to ensure stability, because one of the electrodes that needs to be compensated is affected by the payload resistance. For example, the LM1117 requires a load current of at least 1.7 mA (most ...

Working principle and function of thermal relay Working principle and function of thermal relay

Thermal relay is a maintenance appliance used for overload maintenance of electric motors or other electrical equipment and electrical lines. In the actual operation of the motor, if the machine is in abnormal condition or the circuit is abnormal, the motor will be overloaded, the motor ...

Introduction of inverter energy feedback - Delixi Introduction of inverter energy feedback - Delixi

The essence of energy feedback is active inverter, and the energy feedback of the general inverter is completed by the reverse parallel three-phase inverter at the uncontrolled rectification of the pre-stage of the general inverter, and the regenerative energy is fed to the power grid. The main circuit of the energy feedback equipment is mainly composed of thyristors, IGBTs and IPM modules.

Delixi voltage regulator power selection Delixi voltage regulator power selection

1. The output power of Delixi voltage regulator is the maximum power Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also rational loads that start instantaneous currents.

The main functions of Delixi regulated power supply The main functions of Delixi regulated power supply

The primary effect of Delixi voltage regulator is, of course, to stabilize the voltage. When the grid voltage fluctuates instantaneously, the regulated power supply will compensate for the voltage amplitude with a response speed of 10-30ms 1. Stable voltage: Wangwen Shengyi, Delixi stabilizes ...

How about Delixi switch? How about Delixi switch?

Delixi focuses on the development of green energy-saving industry, the construction of LED ecological industrial chain. It has established an industrial development format with Shanghai as the research and development center and Hangzhou and Jiaxing as the production base of LED lighting products, specializing in the development, production and sales of LED fluorescent lamps, three-proof lamps, downlights, spotlights, street lamps and other high-tech products.

The reason why the Delixi switch socket is hot and hot The reason why the Delixi switch socket is hot and hot

1. The quality of the socket is low First of all, we should check whether the socket is a miscellaneous defective product, the copper clamping force in the defective socket is not enough, resulting in a poor connection between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. Therefore, you must not buy cheap miscellaneous electric ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top