Leakage protector leakage cause - Delixi

Create Date: 2024-8-30 12:03:23|Source: Delixi

1. Poor device

If the terminal posts of the leakage protector are not firmly connected during the installation, it will often lead to the heating and oxidation of the terminal post for a long time, so that the wire insulation layer will be scorched, and accompanied by the smell of ignition and rubber and plastic burning, forming an undervoltage of the line and tripping the leakage protector.

  ​                      Leakage protector leakage cause - Delixi

2. There is a problem with the leakage protector itself

When users buy leakage protectors, they should try to buy them from reputable designated manufacturers or stores, and don't try to buy "three no" leakage protectors from some self-employed people at a low price, which is often a big loss due to a small loss.

3. The leakage protector does not match the load

With the increasing popularity of household appliances, the load current of many families has far exceeded the rated current of the leakage protector on the line, resulting in the leakage protector tripping. This situation generally occurs in the use of high-power household appliances such as air conditioners and electric kettles, and the problem can be easily solved by simply replacing a matching leakage protector from scratch.

4. Leakage and short circuit of load or line

If the leakage protector is tripped due to leakage or short circuit of the load such as household appliances, you only need to unplug the faulty household appliances to send power from the beginning; If the line is leaking or short-circuited, it is relatively difficult to solve some simple problems first, so that some lines can be temporarily restored and transmitted. The specific method is: when the leakage protector trips, first disconnect each branch, and then send the leakage protector, when a certain shunt is sent to the leakage protector that trips, then it can be judged that there is something wrong with the branch. By disconnecting this branch, the other branches will be able to restore electricity. At this moment, if you find that the socket or light fixture in a room is out of power, the problem is often in this area.

5. The incoming voltage of the power supply is too high

This is a rare, but very risky situation, and usually occurs in residential buildings with three-phase and four-wire power supply (which is now ubiquitous in residential buildings). Due to the three-phase imbalance or the misery of small animals such as mice, the voltage drift occurs in the total neutral line of the power supply, and the phase voltage can change from 220V to 380V, which will trip the leakage protector. To identify this problem, one is to use an electric pen to test whether the incoming line is electrified; The second is to see if the neighbors also have tripping phenomenon, if so, most of them belong to this problem; The third is to use a multimeter to measure the voltage of the incoming line. At this moment, please do not forcibly close the leakage protector switch, otherwise it is easy to cause the household appliances to burn out, and in severe cases, it will also lead to adverse consequences such as fire. In addition, lightning strikes on the incoming line will also cause overvoltage to cause the leakage protector to trip.

In short, once the household leakage protector trips, the guidelines should be followed when viewing. First of all, check whether the device is outstanding, then check whether the incoming voltage of the power supply is high (look at the neighbors) and whether there is any problem with the leakage protector itself (remove the outgoing line for power transmission), and then see whether the leakage protector can accept the load of the home appliance, and finally check whether the load, line leakage or short circuit. If you really can't find out the reason, don't move blindly, and ask a professional to investigate. Otherwise, messing up the line is not conducive to eliminating faults.

More on that
The type of regulated power supply - Delixi power supply The type of regulated power supply - Delixi power supply

(1) Ferromagnetic resonant communication regulator. It consists of a full choke and a corresponding capacitor, and has a constant voltage volt-ampere characteristic (AC regulated power supply). (2) Magnetic amplifier communication regulator. The magnetic amplifier and the autotransformer are connected in series, and the impedance of the magnetic amplifier is changed by electronic circuits to stabilize the output ...

Delixi AC contactor fault causes and solutions Delixi AC contactor fault causes and solutions

First, the iron core may not be able to suction power Causes: The power supply voltage is too low or fluctuates too much, the power supply capacity of the operating circuit is lacking or the wire is broken and the control contact is poor, the technical parameters of the coil are inconsistent with the application conditions, and the product itself is damaged. Solution: Turn up the power ...

Delixi meter is too fast or too slow causes and solutions Delixi meter is too fast or too slow causes and solutions

Common fault phenomenon: the meter is fast or slow. The error is positive (negative) and does not meet the requirements Causes: 1. The product has had severe impact and vibration during transfer, installation and transportation; 2. The ambient temperature, preheating and testing time of the product ...

Is a circuit breaker an air switch? - Delixi Is a circuit breaker an air switch? - Delixi

1. Circuit breaker refers to a switchgear that can turn on, carry and turn off the current under normal circuit conditions and turn on, carry and turn off the current under abnormal circuit conditions within a regular time. According to the voltage of Delixi circuit breaker, there are high-voltage circuit breakers and low-voltage circuit breakers. Below 1kV ...

Electrical appliances need voltage regulators for reasons Electrical appliances need voltage regulators for reasons

Typically, every electrical device or device is designed for a wide range of input voltages. Depending on the sensitivity, the operating scale of the device is constrained to a specific value, for example, some devices can tolerate ±10% of the additional voltage, while others can tolerate ±5% or less. ...

Classification of low-voltage electrical appliances - Delixi Classification of low-voltage electrical appliances - Delixi

1. Classified according to the operating voltage level Low-voltage electrical appliances: electrical appliances used to communicate circuits below 1200V and DC 1500V to play the role of on/off, protection, control or regulation. High-voltage electrical appliances: communication 1200V or more, DC 1500V or more. ...

Parameters of Delixi inverter speed controller Parameters of Delixi inverter speed controller

(1) Gain Parameter: The share gain of the speed manipulator. If the gain is too large, it may cause speed fluctuations. (2) Integration time parameter: the integration time of the speed manipulator, that is, the change rate of the output signal of the manipulator under the deviation step signal. The shorter the integration moment ...

Inverter plus output reactor - Delixi Inverter plus output reactor - Delixi

input/output reactor for frequency conversion speed regulation; Because the inverter is often affected by the impact of inrush current and surge voltage in the process of driving the inverter motor operation governor, which will seriously damage the performance and service life of the inverter and the motor, so it is necessary to install a transmission in front of it.

Delixi inverter application case Delixi inverter application case

The traditional textile printing and dyeing industry is a labor-intensive industry, and the degree of automation is not high. Most of the transmissions used are not speed regulation, and most of the occasions that need speed regulation are DC motors, such as warping machines, sizing machines and many printing and dyeing equipment.

Confession of Delixi inverter "energy-saving pioneer". Confession of Delixi inverter "energy-saving pioneer".

  My name is Inverter, and among the many new energy-saving products, I am known as the "energy-saving forward" for my excellent function. In today's world, extreme disasters occur frequently, with melting glaciers, rising sea levels, persistent droughts, and heavy rainfall.

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

Delixi inverter common problems Delixi inverter common problems

1. The pressure of Delixi inverter system is unstable and simple vibration? Answer: The pressure of the system is unstable, which may be due to the following reasons: A. There is a problem with the orientation of the pressure of the pressure sensor collection system, the pressure collection point is too close to the water pump outlet, and the pipeline pressure is affected by the water outlet ...

Delixi solid state relay over AC contactor advantages Delixi solid state relay over AC contactor advantages

Delixi solid state relay and Delixi communication touch device are more used products, so what are the advantages of solid state relay compared to communication touch device, how should we choose when we can choose? 1. First of all, solid...

After 12 years of political participation, Hu Chengzhong said frankly that he is most concerned about the livelihood of private enterprises After 12 years of political participation, Hu Chengzhong said frankly that he is most concerned about the livelihood of private enterprises

  Since 2003, when he was first elected to the National People's Congress Committee, Hu Chengzhong, the current chairman of the executive president of Delixi Group, was re-elected as the National People's Congress Committee for two consecutive terms, and in 2018, he was once again elected as a representative of the people from all over the country.

Inverter maintenance technology - Delixi inverter Inverter maintenance technology - Delixi inverter

(1) Fault characteristics a) *** tripping may occur during operation, but if it is restarted after resetting, it often trips as soon as the speed rises. b) has a large inrush current, but most drives can already be tripped, maintenance without damage. Due to the ...

Delixi Electric rushed to the front line of the anti-epidemic in various places Delixi Electric rushed to the front line of the anti-epidemic in various places

On March 12, Delixi Electric partner Qingdao Hengtong Ruide received an order, continued to deploy a batch of components to be shipped to Laixi cabin hospital, Delixi Electric strategic cooperation plant Qingdao Fengtai Electric overnight deployment, 24 hours smoothly completed handover, escort for Qingdao war epidemic. ...

The change of frequency conversion control mode - Delixi inverter The change of frequency conversion control mode - Delixi inverter

In the process of practical speed regulation, an ordinary frequency-adjustable communication power supply can not meet the requirements of speed regulation and control of asynchronous motors, and must also take into account the effective use of the motor magnetic field, the suppression of the starting current and the acquisition of the desired torque characteristics, such as low-frequency torque characteristics.

Delixi anti-leakage is different from ordinary circuit breakers Delixi anti-leakage is different from ordinary circuit breakers

Circuit breaker refers to a switchgear that can close, carry and break the current under normal circuit conditions, and can close, carry and break the current under abnormal circuit conditions within a specified time. Circuit breakers can be used to distribute electrical energy, infrequently start asynchronous motors, and ...

Delixi molded case circuit breaker Icu=ICS understands Delixi molded case circuit breaker Icu=ICS understands

Delixi 3P air switch, additional current 630A, additional voltage 380V. The Icu=Ics=70kA of this circuit breaker. When the short-circuit current reaches 70kA, can the circuit breaker still be used? Assuming it works, the ICU is now at its limit, which is paradoxical. Assuming it can't be used, Ics is 70KA, clarifying ...

Delixi leakage protector protection Delixi leakage protector protection

1. Under what circumstances does the leakage maintainer not maintain the electric shock? The leakage switch models commonly used in general families are 1P+N and 2P, as far as the leakage maintainer of 1P+N and the leakage maintainer of 2P (single-phase electricity maintenance) are concerned, when people touch the zero line and the front together, people are touched.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top