1. Check the switches in the battery or sensor area as well as in the problem area. Such as tool changers, tool changers and pallet changers. Look for potential alternatives or tools that may be defective through electronic prints.
2. Test the Omron PLC or internal control diagnosis of each output LED. Build each change manually. To stop any sudden movement, place the device on the ESTOP. But be careful, as some ladders are not completely safe.
3. Test devices or Omron PLC diagnostic inputs as you create and disconnect them. If all of this works, go ahead and test the output below. Otherwise, test the energy return of the PLC input with a meter.
4. At this stage, if the device is CNC or direct PLC, it may be appropriate to trigger the device with M-code and then perform the function you are trying to perform.
5. Determine which solenoids or outputs may open under each condition and control them when they are opened. Now test the address of the output LED or Y and see if they are emitted by Omron plc or command.
6. If you turn on the input by looking at diagnostics or LEDs. Check if the voltage output by the PLC is correct with a meter and check if the voltage in the solenoid is correct.
7. Most Omron PLC output is usually switched to 120 volts through some kind of relay. Make sure to test the voltage on the relay coil and power supply, but test the voltage on the relay to the dry contact array.
|
More on that
|
Omron Fiber Optic Amplifier – A common failure of fiber optic amplifiers
1. The optical power meter is not accurate, the domestic optical power meter can only test the equipment with small optical power output, and cannot test the EDFA with high power output, and the optical power meter of the optical amplifier must be imported originally, and the inaccurate instrument can not be used as a standard.
2. The flange of the output port is damaged ...
|
|
What is the main role of Omron micro switches in household appliances?
There are 3 types of micro switches, which perfectly match the precise control needs of household appliances
Micro switch refers to a contact mechanism with a small contact spacing and a snap-action mechanism, a contact mechanism that carries out the switch action with a specified stroke and a specified force, covered with a shell, and a drive rod on its outside, ...
|
|
Common problems and solutions of Omron PLC
1. Omron PLC cannot be connected to the computer
There are two reasons why the PLC and the computer cannot be connected: hardware and software.
The hardware reasons are: the interface type does not match (such as USB, RS232, RS422, RS485, CAN, etc., both sides should be the same.) If you want to use the corresponding converter if you want to), ...
|
|
Omron household oxygen concentrator failure and maintenance method
1/4 of the machine is not running, but the power indicator is on:
Reason: The compressor is overheated, so that the compressor turns on the overheating protection and stops automatically.
Exclusion method: If the machine runs for a long time without stopping, suddenly stops one day, and can run again after the machine is turned off and cooled, this is ...
|
|
Omron C series PLC models and their main meanings
Omron C series P-type machines have three types: basic, extended, and special-purpose, with a total of 4 types of CPU hosts, 6 types of I/O short-range expansion machines, and a variety of dedicated units.
1. The basic unit (also known as the host) has a CPU
Among them, C stands for the series code; (1) Table ...
|
|
Omron PLC cannot be connected to the computer, and the selected port is temporarily used by another program
Compile first, then click the PLC drop-down menu, select online work, pop up to prepare to connect to the PLC, the point is, if the PLC selected by the program is the same as the actual one, and the COM port is set correctly, there is no problem. After connecting, click on the PLC drop-down menu - > transfer - > from the PLC, and the program will be transferred to the computer. ...
|
|
Common faults and maintenance methods of Omron micro switches
One
Omron micro switches in daily use, so we often encounter the phenomenon that the cover of the switch falls off, how does the cover of the switch fall off? The main reason for this is also to be sure that the cover of the switch falls off due to the excessive operation of the key switch.
|
|
The reason and solution for the ERC light of the DA08C output module of Omron plc
The ERC light of the DA08C output module indicates that the module is faulty, which may be caused by the incorrect electrical structure of the output terminal or the power supply overload.
Solution:
1. Check the electrical structure of the output terminal to ensure that the terminal coil is in correct contact;
2. Check the inside of the module ...
|
|
Omron set off a digital low-carbon boom at the expo
From November 5th to 10th, the 5th China International Import Expo was held in Shanghai, where multinational companies from all over the world gathered to participate in the annual international economic and trade event.
As a global expert in digital transformation in the field of automation, Omron has entered the ...
|
|
Omron's new E2EW series proximity sensors have the longest sensing range in the world
Hoffman Estates, Illinois, March 24, 2020 – Manufacturers in the automotive industry are trying to capitalize on the current trend toward electric vehicles and low fuel consumption by building lightweight vehicles and favoring aluminum over iron. With the inclusion of both iron and aluminum ...
|
|
Omron PLC's equipment disassembly sequence and method
(1) Shutdown for maintenance, more than two people must supervise the operation;
(2) Change the mode selector switch on the front panel of the CPU from "Run" to "Stop" position;
(3) Turn off the main power supply of PLC power supply, and then turn off other power supplies to the mold saka;
(4) ...
|
|
Features of Omron 3G3JZ series inverter
1. Standard configuration with RS485 interface, Modbus bus communication function;
2. At 3Hz, it can provide more than 150% torque output and start quickly;
3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive;
4. Equipped with simple energy-saving function;
5. Controlled ...
|
|
Omron Heater Status Monitor K7TM was officially released
In June 2022, Omron Automation (China) Co., Ltd.'s new product [Heater Status Monitor K7TM] was officially released. Without going to the site, through real-time monitoring of heater status, the aging trend of heater equipment that cannot be captured manually is clearly displayed, and predictive maintenance is realized!
In high temperatures ...
|
|
Routine maintenance of Omron PLC
1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented.
2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.
|
|
Omron applications in semiconductor wire bonding equipment
Process introduction
High-purity gold wire (Au), copper wire (Cu) or aluminum wire (Al) is used to connect the Pad and Lead by soldering.
■ PAD is the external contact point of the circuit on the chip
■ Lead is the connection point on the Lead Frame.
W/B is the encapsulation process ...
|
|
Precautions when using Omron switches
One. Omron switch in daily use, basically need to be used every day, when using Omron switch, you need to pay attention not to wet hand operation, to avoid electric shock accidents, and secondly, if the water vapor once invaded the inside of the switch line, it will cause internal damage to the switch, than ...
|
|
Nine main characteristics of Omron relays
1. Extra-small and lightweight
Omron relay has developed and manufactured a very small standard, leading the relay industry at home and abroad, and occupying a dominant position in the market.
2. Low driving current
The driving current is in the range of 6.5-16 mA, which achieves a low current, and in order to protect the environment, it is eco-efficient.
|
|
Omron relays – the role of intermediate relays
1. Replace small contactors
The contacts of the intermediate relay have a certain load capacity, and when the load capacity is relatively small, it can be used to replace the use of small contactors, such as electric roller shutters and the control of some small household appliances. Such an advantage is that it can not only serve the purpose of control, but ...
|
|
How to choose Omron relays?
1. Select the rated working current of the electromagnetic relay coil: For the DC electromagnetic relay driven by transistors or integrated circuits, the rated working current of the coil (generally 2 times the suction current) should be within the output current range of the driving circuit.
2. Select electromagnetic relay contact ...
|
|
【Omron Industry Case】Application case of robot in cell stack welding
Equipment Overview
The stack welding machine is mainly used for the overlap welding of monocrystalline and polycrystalline cells in fully automatic crystalline silicon solar cell modules, and is suitable for series welding of small-size crystalline silicon solar cells.
|
|