1. Measuring contact resistor
Use the resistor file of the universal meter to measure the normally closed contact and the moving point resistor, and its resistance should be 0; The resistance of the normally open contact and the moving point is infinite. This makes it possible to distinguish which is a normally closed contact and which is normally open.
2. Test the coil resistance
The resistance of the solenoid coil of the Omron relay can be measured in the R×12Ω range of the universal meter, and then the solenoid coil can be distinguished whether there is an open circuit problem.
3. Measure the pick-up working voltage and the amount of pick-up current
Call the adjustable regulated power supply and the galvanometer, type two sets of working voltages to the Omron relay, and serial the galvanometer in the control loop of the power supply system for detection. Gradually, increase the working voltage of the switching power supply, and record the working voltage and the amount of current when you hear the sound of Omron relay settling. It can be found, and you can try several times to find the mean.
4. Measure the released working voltage and the amount of current released
When the Omron relay produces a pick-up, then slowly reduce the working voltage of the power supply system, when the Omron relay is released again, the working voltage and current amount are recorded, and the working voltage and current amount are recorded at this time, so as to try to get the average release of the working voltage and the amount of current released several times. Under normal circumstances, the working voltage of Omron relay is about 12-60% of the pick-up working voltage, if the released working voltage is very small (less than 1/12 of the pick-up working voltage), everything can not be used normally, which will lead to a threat to the reliability of the power supply circuit.
|
More on that
|
How to choose Omron micro switches?
1. Understand how the shape and scale of the switch affect other characteristics
The scale is important when choosing a micro switch. The switching scale is directly related to its characteristics, including current scale, stroke, and operating force. For example, the smallest microswitch on the market today measures 0.50" x 0. ...
|
|
Extended unit address assignment for Omron PLC
2. Extend unit address allocation
The function of the expansion unit is to expand the input and output, and the expansion unit starts from the next channel after the allocation channel of the CPU unit, and assigns the address backwards.
CP1W Expansion Unit
For example, the CPU unit comes with an input that occupies 0 channels and 1 pass ...
|
|
Common faults and maintenance methods of Omron micro switches
One
Omron micro switches in daily use, so we often encounter the phenomenon that the cover of the switch falls off, how does the cover of the switch fall off? The main reason for this is also to be sure that the cover of the switch falls off due to the excessive operation of the key switch.
|
|
Omron PLC--C200HE/C200HG/C200HX series product model
1. C200HE-CPU11-E CPU unit memory 3.2K maximum I/O points: 640 points
2. C200HE-CPU32-E CPU unit memory 7.2K maximum I/O points: 880 points
3. C200HE-CPU42-E CPU unit RAM 7.2K Max I/O points: 880 points with RS232C ...
|
|
Common problems and solutions in the maintenance process of Omron PLC
1. CPU abnormality:
When the CPU is abnormally alarmed, check all the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may have problems in turn, find out the problem units, and deal with them accordingly
2. Memory abnormality:
Memory anomaly ...
|
|
Omron Relays – What are the main functions of relays?
(1) Expand the control range: for example, when the control signal of the multi-contact relay reaches a certain value, it can be changed, interrupted and connected to multiple circuits at the same time according to the different forms of the contact group.
(2) Amplification: For example, sensitive relays, intermediate relays, etc., with a very small ...
|
|
What should Omron PLC pay attention to when selecting a model
Omron PLC is a compact PLC with perfect functions, which can provide high value-added machine control for industry-leading conveying and decentralized control; It also has the ability to upgrade through a variety of advanced built-in boards, large program capacity and memory units for efficient software development in the Windows environment ...
|
|
Omron Switches – What Aspects Are Needed for Switching Power Supply Design?
1. Wiring
The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...
|
|
The application of Omron tension control in automobile motor winding
Process introduction
In recent years, the motor industry has shown a rapid upward trend, new products, new technologies are constantly updated and iterative, resulting in increasingly fierce competition between motor manufacturers, how to improve equipment performance, improve productivity, is the current motor manufacturers need to solve the problem.
...
|
|
Features of Omron 3G3JZ series inverter
1. Standard configuration with RS485 interface, Modbus bus communication function;
2. At 3Hz, it can provide more than 150% torque output and start quickly;
3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive;
4. Equipped with simple energy-saving function;
5. Controlled ...
|
|
【Omron industry case】Predictive maintenance of smoke machine in automobile welding workshop
Process introduction
Automobile welding is the second of the four major processes in vehicle production, which mainly assembles stamped body components into a complete body. In the welding process, spot welding and arc welding of robots are the mainstay, and there will be a station for visual inspection of the welding status in the middle.
Make...
|
|
Common causes and solutions of PLC failures in Omron operation
Fault phenomenon: The analog module CJ1W-DA041 outputs 4-20mA current for 4 channels, of which channels 2 and 3 are normal, and channels 1 and 4 have no current output.
Analyzing the circuit, the 4 current outputs use 4 manifold LT1490 for D/A conversion, and first measure the manifold LT on 1 and 4 channels.
|
|
The solution to the E4 fault code on the Omron electronic blood pressure monitor
The E4 fault code usually appears on the display of the blood pressure monitor, indicating that the blood pressure monitor is poorly connected to the cuff or that the cuff is falling off. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check that the cuff is worn correctly and whether it is loose...
|
|
How to classify Omron signal relays?
1. Classified according to the principle of action
The electromagnetic relay drives the armature and the movable part to act through the suction generated by the current in the relay coil in the electromagnet and changes the working state of the contact system. Such as DC stepless relays, DC polarized relays, AC relays, binary differential relays...
|
|
How does Omron PLC input the rising/falling edge?
The first
1. First of all, we open the CX-P software, set the PLC model, enter the programming section, and prepare for programming.
2. Usually when we program, we are used to entering LD instruction programming, when we need to input the rising edge, we need to enter @LD0.00, you can.
3. Down...
|
|
Omron PLC's maintenance procedures and equipment cleaning regulations
1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found;
(2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...
|
|
Omron C series PLC models and their main meanings
Omron C series P-type machines have three types: basic, extended, and special-purpose, with a total of 4 types of CPU hosts, 6 types of I/O short-range expansion machines, and a variety of dedicated units.
1. The basic unit (also known as the host) has a CPU
Among them, C stands for the series code; (1) Table ...
|
|
Fault maintenance methods commonly encountered in the operation of Omron PLC
(1) Failure of peripheral circuit components
This kind of failure is relatively common in PLC maintenance and usually occurs frequently after a certain period of work. If there is a component damage fault in the PLC control loop, the PLC control system will stop working immediately and automatically.
The input circuit is a PLC receiving switching quantity ...
|
|
Omron Health & Medical Products Shanghai Delivery Emergency Service Opens on the Next Day
At present, the epidemic prevention and control situation in Shanghai is severe and complex, and the demand for chronic disease management and medical consumables in the family is prominent.
|
|
The application of Omron in laser welding of the top cover of automotive power battery
Process introduction
The assembly process of automobile power battery and cell section is divided into:
1.Hot pressing 2.Tab welding 3.Adapter welding 4.Coating 5.Into the shell 6.Top cover welding
Among them, top cover welding is the last process, which uses the laser welding process to combine the top cover with ...
|
|