Omron alarm code analysis

Create Date: 2024-8-30 12:03:23|Source: Omron/Omron

Warning display

Over Torque Detection (OL2)

FUNCTION code error (CE01)

Registers NO. Error (CE02)

Data Error (CE03)

Slave Execution Error (CE04)

Slave Execution (CE06)

Communication Timeout (CE10)

Displays an anomaly

Overcurrent (OC)

Acceleration Current Excess (OCA)

Current Excess (OCD) during deceleration

Constant State Current Exceeding (OCN)

Overvoltage (OV)

Main circuit voltage is too low (LV)

Heatsink overheating (OH1)

Power PCB Overheat (OH2)

Inverter Overload (OL)

Motor Overload (OL1)

Over Torque Detection (OL2)

Grounding (GFF)

Input Power Phase Loss (PHL)

External Exception (EF)

Frequency Command Input Signal Exception (AERR)

External Base Blockade (BB)

EEPROM Write Exception (CF1.0)

EEPROM Read Exception (CF2.0)

U-phase circuit anomaly (CF3.0)

V-phase circuit anomaly (CF3.1)

W-phase circuit anomaly (CF3.2)

Voltage control circuit abnormality (CF3.3)

Temperature Detector 1 Anomaly (CF3.4)

Temperature Detector 2 Anomaly (CF3.5)

Current Control Circuit Abnormality (HPF1)

Overvoltage Detection Circuit Abnormality (HPF2)

Ground Detection Circuit Exception (HPF3)

Overcurrent Detection Circuit Exception (HPF4)
Omron alarm code analysis

More on that
Analysis of common faults and causes of Omron relays Analysis of common faults and causes of Omron relays

First, the condition that the relay is not turned on 1. If the load current exceeds the rated conversion current of the relay, the relay will have a short circuit fault, and the relay with a large rated voltage should be replaced 2. At the working temperature where the relay is located, the amount of current borne by the relay is ...

What's the deal with Omron PLC without output voltage? What's the deal with Omron PLC without output voltage?

1. The indicator light at the output of the PLC is on, indicating that the DO point of the PLC has been closed; 、 2. The DO point of PLC is equivalent to a dry contact switch, imagine that an on/off switch on a line is closed, if you measure the voltage on both sides of this switch, there will be no voltage, thinking that the switch itself ...

The Omron mobile robot can move a payload of up to 250 kg The Omron mobile robot can move a payload of up to 250 kg

Omron's LD-250 can be used to transport large automotive parts, such as gearboxes and large quantities of packaging materials, which are normally handled by human workers using trolleys. The robot is made of a sturdy metal enclosure that can withstand unexpected external shocks and requirements for more ...

Common fault problems of Omron relays Common fault problems of Omron relays

1. Do not exceed the rated voltage of load current during the use of OMRON relay, because when the applied rated voltage is too large, it may cause a local short circuit between the cores of the OMRON relay coil and poor operation of the AC operation relay. And it may also cause a succession ...

Analysis of common failures of Omron PLC Analysis of common failures of Omron PLC

1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself. 2. System failure ...

Omron PLC--CPM2A series product model Omron PLC--CPM2A series product model

1. CPM2A-20CDR-D 20-point CPU unit, DC24V 12-point in, 8-point relay output, comes with RS232 2. CPM2A-20CDT-D 20-point CPU unit DC24V 12-point to 8-point transistor output with RS232 3. CPM2A-30CDR-D 30 points CPU unit DC24V 18 points ...

The working principle and purpose of Omron relays The working principle and purpose of Omron relays

How it works Add a certain voltage at both ends of the coil, a certain current will flow through the coil, thus producing an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction and attract to the core, thereby driving the dynamic contact and static contact (normally open contact) of the armature ...

Features of Omron PLC programming Features of Omron PLC programming

Programming features of Omron PLC.   Graphical instruction structure: The program is represented graphically, and the instructions are composed of different graphic symbols, which are easy to understand and remember. The software developers of the system have compiled the individual operating functions required for industrial control into symbolic graphics that the user can use according to the ...

How to choose the right Omron switch? How to choose the right Omron switch?

1. Top button switch: suitable for occasions that require frequent pressing, such as video game consoles, calculators, etc. 2. Side button switch: suitable for occasions that need to be pressed on the side, such as mobile phones, remote controls, etc. 3. Knob switch: suitable for occasions that require rotary operation, ...

Omron Relays – The role of signal relays Omron Relays – The role of signal relays

1) Expand the scope of control. For example, when the control signal of a multi-contact relay reaches a certain value, it can be changed, interrupted, and connected to multiple circuits at the same time according to the different forms of contact groups. 2) Zoom in. For example, sensitive relays, intermediate relays, etc., with a very small control ...

Omron PLC--CP1H series product model Omron PLC--CP1H series product model

1. CP1H-X40DR-A 40-point CPU unit, 24-in 16-point relay output. High speed counting 50/100kHz 4-axis .usb port programming. 2. CP1H-XA40DR-A 40 points CPU unit, 24 into 16 points relay output. High speed counting 50/100kHz 4-axis .usb port programming. Integrated Simulation ...

What are the maintenance precautions for Omron relays? What are the maintenance precautions for Omron relays?

1. In the operation of Omron relay, if there is any abnormal sound or other abnormal phenomena, the operation should be stopped immediately, and the professional maintenance personnel should be notified to come for maintenance, and the normal operation can only be put into normal operation after troubleshooting. 2. During the maintenance process, check whether the spring is deformed, old...

Omron's official website officially launched the Components product special section Omron's official website officially launched the Components product special section

Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") officially launched the Components product section on its official website. A huge product lineup of more than 200,000 pieces, carrying ingenuity and quality, can cover almost all the needs of the production site, help the comprehensive evolution of the production site, and empower the future wisdom.

What are the characteristics of Omron 3G3JZ series inverter? What are the characteristics of Omron 3G3JZ series inverter?

1. Standard configuration with RS485 interface, Modbus bus communication function; 2. At 3Hz, it can provide more than 150% torque output and start quickly; 3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive; 4. Equipped with simple energy-saving function; 5. Controlled ...

Omron household oxygen concentrator failure and maintenance method Omron household oxygen concentrator failure and maintenance method

1/4 of the machine is not running, but the power indicator is on: Reason: The compressor is overheated, so that the compressor turns on the overheating protection and stops automatically. Exclusion method: If the machine runs for a long time without stopping, suddenly stops one day, and can run again after the machine is turned off and cooled, this is ...

What are the advantages of Omron relays? What are the advantages of Omron relays?

1. The relay is small and still weldable. The relays in SSOP/USOP packages feature directly exposed terminals for excellent visibility and easy installation. 2. Ultra-small and lightweight: In addition to SSOP and USOP, ultra-small packages contribute to the miniaturization of devices. ...

Introduction to the characteristics of Omron 3G3RX series inverter Introduction to the characteristics of Omron 3G3RX series inverter

1. High starting torque of more than 200% at 0.3Hz, 0Hz to ensure 150% torque output; 2. Closed-loop vector has servo functions such as position control, origin reset, and electronic gear ratio; 3. Over-current and over-voltage suppression function; 4. The fast ...

Routine maintenance of Omron PLC Routine maintenance of Omron PLC

1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented. 2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.

Omron set off a digital low-carbon boom at the expo Omron set off a digital low-carbon boom at the expo

From November 5th to 10th, the 5th China International Import Expo was held in Shanghai, where multinational companies from all over the world gathered to participate in the annual international economic and trade event. As a global expert in digital transformation in the field of automation, Omron has entered the ...

【Omron industry case】The application of robots in the assembly line of automobile high-pressure oil pump 【Omron industry case】The application of robots in the assembly line of automobile high-pressure oil pump

Equipment Overview The high-pressure oil pump (abbreviation: HDP) is the main power source to drive the fuel pressure of the automobile engine.   The "high-pressure oil pump robot automatic assembly line" mainly realizes the intelligent supply of each component on the high-pressure oil pump and the automatic assembly of each component by the robot.   Work...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top