Using an Omron electronic thermometer, which is displayed digitally and compared with a conventional thermometer, there is a small chance of error, generally no more than 0.1 degrees, so there is little need to worry about inaccuracies. Every time you use it, it's also very simple, just press the power switch, and when it's done, there is a beep reminder, and the design is humanized.
Omron electronic thermometers are easy to use, high-tech, and have a memory function that can help people draw cycle charts. Compared to traditional thermometers, Omron electronic thermometers are more accurate and can be used as a daily temperature check.
How to use the Omron electronic thermometer.
Press the POWER switch to turn on the power. When the screen shows L and °C flashes, it means that the temperature measurement enters automatically.
Place the sensing head in the mouth within 30 seconds and secure it with the base of the tongue.
The measurement time for holding still and waiting for the predictive measurement is about 60 seconds. During the measurement, the screen flashes with the text of °C and the forecast, showing the body temperature value at that time. The measurement time for the measured measurement is about 5 minutes. During the measurement, the screen flashes with the text of °C and the actual measurement, showing the text of the prediction and the predicted body temperature value.
After the measurement is over, take out the inductor buzzer to make a prompt sound, take out the inductor in the mouth, and the measurement is over. Predictive measurement displays the prediction word and body temperature value, and then automatically starts the actual measurement. The measured measurement displays the measured word, and the temperature value is recorded.
Press the POWER switch, and if you forget to cut off the power, the thermometer will automatically turn off after about 5 minutes.
|
More on that
|
Routine maintenance of Omron PLC
1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented.
2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.
|
|
How can Omron micro switches meet the market demand for smart locks?
Nowadays, the smart lock market has a wide variety of names, and it can't help but give people a sense of "random flowers gradually charming eyes". So, how to choose a cost-effective smart lock? In fact, in smart locks, micro switches can be said to occupy an important position. Microswitches ...
|
|
Instructions for the use of Omron relays
One. Omron relays should be installed in a well-ventilated environment with room temperature and humidity, and there are no flammable gases, dusts and other dangerous factors in the installation environment to ensure that Omron relays can be used normally after being put into operation.
Two. The selection of Omron relays should be in line with the actual needs.
|
|
Application of Omron Robotics in Medical Cartoner Loading System
Process introduction
In 2020, the new crown epidemic ravaged the world, and as of February 2022, the number of confirmed cases and deaths exceeded 400 million.
In the face of the continued ravages of the new coronavirus, the new crown epidemic ...
|
|
Selection rules for Omron relays
1. Coil voltage: also known as input voltage, used to control the contact on/off, with AC24V, DC24V, AC220V and other specifications
2. Contact capacity: the voltage and current of the load
3. Contact structure: 2C (double-pole double-throw), 4C (four-pole double-throw), 1A, 1B, etc
4. Load type ...
|
|
Omron set off a digital low-carbon boom at the expo
From November 5th to 10th, the 5th China International Import Expo was held in Shanghai, where multinational companies from all over the world gathered to participate in the annual international economic and trade event.
As a global expert in digital transformation in the field of automation, Omron has entered the ...
|
|
Analysis of the causes of Omron S8 series switching power supply failures
1. Fault phenomenon: After powering on, the power supply does not respond.
2. Cause of failure:
(1) The input power supply voltage is insufficient and does not reach the specified range.
(2) The input power supply voltage is instantaneously impulsed, resulting in damage to the input components (such as fuses, rectifications, etc.) as shown in the figure: ...
|
|
G7 Coffee and Omron Health Medical delivered health energy packs to help medical staff
"It's really nice to receive such an exclusive gift during the pandemic."
"I feel that my efforts have been recognized, thank you!"
"I've been running around for the health of others, but I didn't expect that some people are silently concerned about our health."
This...
|
|
Key Features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
What are some common troubleshooting methods for Omron?
(1) Failure of peripheral circuit components
This kind of failure is more common in PLC maintenance, and it is generally a frequent occurrence in failures after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system will immediately and automatically stop working. The input circuit is P...
|
|
Omron PLC online modifies the procedure steps
1. Plug the data cable or network cable into the PLC socket and connect one end to the computer (Ethernet needs to set the computer IP and the IP of the PLC CPU to be in the same network segment)
2. Download the latest program from the PLC, or open the backup program, online program
3. Find the place in the program that needs to be modified.
|
|
The reason and solution for the ERC light of the DA08C output module of Omron plc
The ERC light of the DA08C output module indicates that the module is faulty, which may be caused by the incorrect electrical structure of the output terminal or the power supply overload.
Solution:
1. Check the electrical structure of the output terminal to ensure that the terminal coil is in correct contact;
2. Check the inside of the module ...
|
|
What's going on if Omron PLC can't be installed?
1. Open the CX-programmer software;
2. Use rs232 and other communication lines to connect to PLC;
3. Open "PLC" -> "Auto Online"; - >> "Direct Online";
4. Select "Connection Type" and click "Connection".
5. In the pop-up window, click ...
|
|
Common causes and solutions of PLC failures in Omron operation
Fault phenomenon: The analog module CJ1W-DA041 outputs 4-20mA current for 4 channels, of which channels 2 and 3 are normal, and channels 1 and 4 have no current output.
Analyzing the circuit, the 4 current outputs use 4 manifold LT1490 for D/A conversion, and first measure the manifold LT on 1 and 4 channels.
|
|
The Omron mobile robot can move a payload of up to 250 kg
Omron's LD-250 can be used to transport large automotive parts, such as gearboxes and large quantities of packaging materials, which are normally handled by human workers using trolleys.
The robot is made of a sturdy metal enclosure that can withstand unexpected external shocks and requirements for more ...
|
|
The working principle and purpose of Omron relays
How it works
Add a certain voltage at both ends of the coil, a certain current will flow through the coil, thus producing an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction and attract to the core, thereby driving the dynamic contact and static contact (normally open contact) of the armature ...
|
|
There are four main characteristics of Omron PLC
1. High reliability
The PLC replaces a large number of intermediate relays and time relays in the relay control system with software, and the wiring can be reduced to less than one-tenth of the relay control system, which greatly reduces the possibility of poor contact contact. In addition, the PLC itself has a strong self-diagnosis ...
|
|
Omron's official website officially launched the Components product special section
Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") officially launched the Components product section on its official website. A huge product lineup of more than 200,000 pieces, carrying ingenuity and quality, can cover almost all the needs of the production site, help the comprehensive evolution of the production site, and empower the future wisdom.
|
|
Precautions when using Omron switches
One. Omron switch in daily use, basically need to be used every day, when using Omron switch, you need to pay attention not to wet hand operation, to avoid electric shock accidents, and secondly, if the water vapor once invaded the inside of the switch line, it will cause internal damage to the switch, than ...
|
|
The solution to the Omron blood pressure monitor E3 failure
The E3 fault code usually appears on the display of the blood pressure monitor and indicates that the cuff is too tight or too loose. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Adjust the tightness of the cuff to make sure the cuff is neither too tight nor too loose.
2. Check the sleeve ...
|
|