Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

What are the conditions that must be met for high-voltage appliances?

A: A. The insulation is safe and reliable;

B. Long-term operation under rated current and certain short-term overload capacity;

C. Able to carry the thermal and electrodynamic effects of short-circuit currents without damage;

D. The switching current can be safely and reliably closed and interrupted;

E. Outdoor ones should withstand certain natural disasters.

  High voltage appliances must meet the needs of the workplace?

A: A. Rated voltage;

B. Maximum operating voltage;

C. Rated current;

D. Rated short-circuit breaking current;

E. Short-time withstand current and peak withstand current.
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

More on that
Rittal enclosures – how to choose the size of the cabinet? Rittal enclosures – how to choose the size of the cabinet?

1. Determine the size of the server, such as depth size, height size (how many U), and whether it is a 19-inch rack-mounted installation. 2. Choose a cabinet according to the installation space: If the server is a 19-inch rack-mounted installation, then a standard cabinet can be used. Root...

Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50) Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50)

41. Can power lines be divided into according to the erection method? A: Overhead power lines and cable lines. 42 What is a protective relay? Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the switch to trip or send out a signal ...

Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation

Sincere service, strength and responsibility In 2022, which was full of changes, Rittal and its partners Hengxin Software and Yokogawa Automation (part of the Yokogawa Group) withstood the challenges brought about by the pandemic and moved forward hand in hand. In the cooperation project, Rittal worked with the customer to overcome difficulties and complete the project delivery in a timely manner, ...

Common faults and troubleshooting methods of oil coolers - Rittal cabinets Common faults and troubleshooting methods of oil coolers - Rittal cabinets

Fault symptom 1: insufficient cooling capacity Cause analysis (1) The room or box is not sealed or the thermal insulation performance is poor (2) The evaporator frost is too thick (3) The efficiency of the compressor deteriorates (4) The expansion valve is too large or too small (5) There are more ...

Rittal cables – the types of cables in detail Rittal cables – the types of cables in detail

Flame retardant rubber sheathed cable 1. Use This product is a series of mining rubber sheathed flexible cables. It is suitable for power connection of shearers and similar equipment devices with rated voltage Uo/U of 1.9/3.3KV and below. It is mostly used in coal mines. 2. Conditions of use Long-term core ...

Rittal cabinets – the role of network cabinets and how to wiring them Rittal cabinets – the role of network cabinets and how to wiring them

What is a Network Cabinet? The network cabinet is a kind of rectangular cabinet composed of two parts: frame and cover, which can install switches, optical fiber adapters, optical fiber distribution frames and other equipment in a cabinet, with electromagnetic isolation, noise isolation, ventilation and heat dissipation, anti-vibration, anti-corrosion, etc.

Rittal fans – analysis of the reasons why cooling fans do not rotate Rittal fans – analysis of the reasons why cooling fans do not rotate

1. Power failure: The power supply of the fan fails, such as the power cord is disconnected, the power plug is loose, etc., which will cause the current to fail to transmit normally, resulting in the fan stopping and rotating. 2. The temperature is too low: Some heat dissipation windbreakers have a temperature protection function, when the temperature is too low, the fan will automatically ...

Rittal cables – common causes of cable failure Rittal cables – common causes of cable failure

1. External force damage. Judging from the operation analysis in recent years, especially in Haipudong, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in direct burial on cables ...

Rittal cables – what are the types of industrial wires and cables commonly used? Rittal cables – what are the types of industrial wires and cables commonly used?

Industrial wires and cables include single-core wires and cables, rubber cables, shielded control cables, flame-retardant cables, fire-resistant cables, etc. Single-core wire and cable It means that there is only one conductor in the insulation layer, the common BV wire, and B represents the wiring; V stands for insulating polyvinyl chloride. Suitable for AC ...

Rittal cabinets – the characteristics of GDD and GCK low-voltage distribution cabinets Rittal cabinets – the characteristics of GDD and GCK low-voltage distribution cabinets

1. GGD AC low-voltage distribution cabinet has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, seriality, strong practicability, novel structure and high protection level. It can be used as a replacement product for low-voltage switchgear. Structural features ...

Rittal X Kongsberg | Smart ship "Wei" can be expected Rittal X Kongsberg | Smart ship "Wei" can be expected

Smart ships are a key area clearly supported by national policies. Driven by policy guidance and innovation, China has achieved phased results in the research and construction of smart ships. As the world's leading provider of enclosure systems, Rittal has a wide range of applications in the marine and port sectors.

Cable management components for Rittal's IT cabinets Cable management components for Rittal's IT cabinets

An IT cabinet generally needs to arrange a lot of cables, including strong current cables for power supply equipment, optical fibers used for communication, and weak current cables for signal transmission. So many cables in a cabinet if not well packed up form a clutter of cables in the cabinet, and then ...

When winter arrives, Rittal heaters bring warmth to the cabinets When winter arrives, Rittal heaters bring warmth to the cabinets

We know that electronic and electrical equipment is installed in the electrical cabinet, in fact, there are working temperature requirements, the general storage temperature can not be lower than minus 25 degrees, the working temperature can not be lower than minus 20 degrees, but now the outdoor temperature in the north is very simple to reach the lower limit of this working temperature, this time heating ...

The Rittal enclosure model 6380.510 is designed to be ultra-slim and matched to the embedded devices The Rittal enclosure model 6380.510 is designed to be ultra-slim and matched to the embedded devices

Product Introduction Brand: Rittal cabinets Product model 6380.510 Aluminum box, strong thermal conductivity, excellent passive heat dissipation. For relatively small panels and control schemes. The ultra-slim design matches the embedded device and takes up almost no space. Type: Support ...

Rittal cabinets - judgment and handling of common faults in high-voltage switchgear Rittal cabinets - judgment and handling of common faults in high-voltage switchgear

1. Judgment and treatment of sudden tripping fault of high-voltage switchgear during operation 1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature. 2) Judgment method: judging the cause of the fault can be based on the relay off, remote ...

Rittal Cabinet - Knowledge Quiz of High and Low Voltage Distribution Cabinet (51-60) Rittal Cabinet - Knowledge Quiz of High and Low Voltage Distribution Cabinet (51-60)

51 What are the factors that affect the degree of harm to the human body caused by electric shock? Answer: Factors such as the magnitude of the current, the duration of the current, the path of the current, the resistance of the human body and the frequency of the current. 52 Types of electric shock? Answer: Direct electric shock, indirect electric contact, inductive ...

Rittal Cables – What are the causes of faults in wires and cables? Rittal Cables – What are the causes of faults in wires and cables?

1. External force damage. Judging from the operation analysis in recent years, especially in Haipu East, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in civil engineering on directly buried cables ...

What are the advantages of Rittal enclosure processing – sheet metal cabinets? What are the advantages of Rittal enclosure processing – sheet metal cabinets?

1. The cabinet and chassis products provide space for power supplies, motherboards, various expansion boards, floppy disk drives, optical disk drives, hard disk drives and other storage devices, and these spare parts are firmly fixed through the internal supports, brackets, various chassis screws or clips and other connectors inside the cabinet and chassis.

Alarm code analysis for Rittal chillers Alarm code analysis for Rittal chillers

1. E1: Temperature sensor failure 2. E2: Humidity sensor malfunction 3. E3: Compressor overload protection 4. E4: Compressor phase loss protection 5. E5: Compressor short circuit protection 6. E6: Compressor switch failure 7. E7: Fan failure ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is Peak Load? What is trough load? What is Average Load? A: Peak load refers to the maximum load that can occur on the grid and the user in a day. The trough load is the hourly average of the least amount of usage that occurs in the grid and the users in a single day.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top