1. Determine the size of the server, such as depth size, height size (how many U), and whether it is a 19-inch rack-mounted installation.
2. Choose a cabinet according to the installation space: If the server is a 19-inch rack-mounted installation, then a standard cabinet can be used. Select the depth size of the server cabinet according to the depth size of the server (for example, if the depth of the server cabinet is less than 700mm, then you can choose a cabinet with a depth of 1000mm), and determine the total height of the server cabinet according to the number of server heights and the number of servers to determine the total height of the server cabinet (which can be calculated by the number of U).
3. Choose the cabinet according to the power size: choose the cabinet according to the power of the server, the total power of the server installed inside the server cabinet is 6KW or less, and the maximum is not recommended to exceed 10KW. Because the total power of the server inside the cabinet is too large, the heat dissipation density of the cabinet will be too large, resulting in low cooling efficiency and no energy saving.
4. There are several points that need to be considered in the server cabinet: the load-bearing capacity of the cabinet (generally about 1300KG, and some can do about 1500KG), the through-hole ratio of the front and rear doors of the cabinet (generally about 70% is better), the rationality of the installation and wiring structure inside the cabinet (the standard U-column installation method, there are accessories such as cable management racks or cable management boards that facilitate wiring).
|
More on that
|
Rittal cabinets – installation steps and rules for cabinet placement
Cabinet installation steps:
1. Before installing the cabinet, check whether the exhaust device of the cabinet is stable, whether the number of equipment support plates is complete, and whether the pulleys and support columns are stable.
2. The model, specification and device orientation of the cabinet should meet the planning requirements.
3. Cabinet ...
|
|
Rittal for AE model 2733.000
Rittal for AE
Product model 2733.000
Retrofit on AE in place of a door, or on a sufficiently large flat surface.
Product Description: For retrofitting on AE instead of doors and flat surfaces
Material: Frame: Aluminum, by natural aluminium anode
|
|
Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?
1. In principle, the power cord and network cable of the cabinet should be sorted out separately;
2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other;
3. If there are too many devices in the cabinet, the equipment should be numbered;
4. For each line ...
|
|
A basic introduction to a very popular explosion-proof box in Rittal
As a commonly used box in Rittal, many users do not understand the material and structure of this series of boxes.
Now I would like to introduce the Rittal explosion-proof enclosure
Apply:
– Zones 1 and 2 or Zones 21 and 22 according to 94/9/EG
– Ambient temperature range: -30°C.
|
|
What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure?
1. Safety: As the carrier of electrical equipment, the outdoor cabinet must have excellent structural design, solid materials, and firm bottom fixation to meet the requirements of strong typhoons, strong rainstorms, and even strong earthquakes. At the same time, the cabinet should have anti-leakage, anti-short circuit, anti-cut and other requirements.
2. Rainproof and dustproof ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is eddy current? What are the harms of eddy currents?
Answer: When an alternating current is passed through a wire, an alternating magnetic field is created around the wire. An induced current is generated inside the whole conductor in an alternating magnetic field, and because this induced current forms a closed loop inside the whole conductor, ...
|
|
Rittal Cables – an introduction to the performance of industrial control cables
Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of cables for power transmission at working temperatures, current carrying capacity, short circuit and overload capabilities, the thermal deformation and thermal impulse resistance of the constituent materials.
|
|
Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets
1. Normal power transmission operation process of low-voltage distribution cabinet:
1. All load switches are disconnected, confirm that the switches have at least one breakpoint;
2. Confirm that the power switch is in the disconnected position;
3. Send the power supply to the operation circuit, and the status indication is normal;
4. The incoming switch is - isolated ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is Phase Order?
Answer: It is the order of the phases, which is the sequence in which the instantaneous value of alternating current changes from negative to positive through zero
What is the safety distance of the human body grounding point when a grounding fault occurs in high-voltage equipment?
A: Indoor should be larger than 4 m, outdoor should be larger than 8 ...
|
|
Rittal cables – common causes of cable failure
1. External force damage. Judging from the operation analysis in recent years, especially in Haipudong, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in direct burial on cables ...
|
|
How do I set the temperature of my Rittal aircon by remote control or panel?
The temperature setting of the Rittal air-conditioner can be operated via a remote control or a panel. The specific steps are as follows:
1. Turn on the power of the air conditioner and press the "on/off" button on the remote control or the power switch on the panel.
2. Press the "Mode" button on the remote control or the ...
|
|
A detailed presentation of Rittal's new smart electronic lock
With the development of data centers in the direction of more intelligent and high reliability, the information stored in the servers in the IT cabinet is becoming more and more important, and the operation and maintenance of the data center needs to be able to manage the door opening of the cabinet more effectively to avoid server downtime caused by human factors.
Traditional Mechanical Cabinet Locks ...
|
|
Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets
What is a substation?
A: It is a power supply hub that receives electrical energy from the power system, transforms (boosts or downgrades), and then distributes the power.
What is the main role of transformers in the power system?
Answer: The main function is to convert the voltage to facilitate ...
|
|
The solution to the A17 fault reported by the Rittal cabinet air conditioner
1. The Rittal air conditioner does not start when it is turned on, and the A17 is faulty.
Check that the power supply voltage is 220V, normal; Detect that the battery voltage of the remote control is 3V, which is normal; Measure the fuse resistance value of the air conditioner compressor with a multimeter as infinity, which is normal.
2. The Rittal air conditioner does not start when it is turned on, and the display is not started.
|
|
Presentation of the features of the Rittal cabinet TS8 seismic kit
Since ancient times, truss planning has been the way to create a stable and earthquake-tolerant mechanical structure. This plan consists of individual members connected at two ends, which form a triangle. The members are almost exclusively subjected to compressive or tensile forces, which makes the entire structure very strong.
|
|
The difference between imitation Rittal and genuine Rittal
The quality and brand awareness of Rittal are good, and the application market is also large, but due to various reasons such as price, delivery time, service, etc., many customer groups do not want to use Rittal products, but choose to go to the manufacturer to order imitation Rittal products.
...
|
|
Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk"
The Age of Discovery, which began at the end of the 15th century, linked the world and was one of the most important historical steps in the process of human civilization.
In the 21st century, in the development trend of global interconnection and China's intelligent manufacturing, the shipbuilding industry has ushered in high-energy development prospects.
Smart ships, low...
|
|
Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation
Sincere service, strength and responsibility
In 2022, which was full of changes, Rittal and its partners Hengxin Software and Yokogawa Automation (part of the Yokogawa Group) withstood the challenges brought about by the pandemic and moved forward hand in hand. In the cooperation project, Rittal worked with the customer to overcome difficulties and complete the project delivery in a timely manner, ...
|
|
When winter arrives, Rittal heaters bring warmth to the cabinets
We know that electronic and electrical equipment is installed in the electrical cabinet, in fact, there are working temperature requirements, the general storage temperature can not be lower than minus 25 degrees, the working temperature can not be lower than minus 20 degrees, but now the outdoor temperature in the north is very simple to reach the lower limit of this working temperature, this time heating ...
|
|
The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder
Product Model 2485.100
Replace standard locks with or without a secure semicircular cylinder.
Type::C
Color: RAL 9011
A note on the order number: Not suitable for AE 1018.600
Lock: Cylinder: No safety cylindrical cylinder
...
|
|