1. Clean the motor and remove the dust and sludge outside the motor base in time. If there is a lot of dust in the environment, it is best to clean it once a day.
2. Check and wipe the motor terminals. Check whether the junction box wiring screws are loose or burned.
3. Check the screws of each fixed part, including anchor screws, end cover screws, bearing cover screws, etc. Tighten the loose nut.
4. Check the transmission device, check whether the pulley or coupling is bold or damaged, and whether the installation is firm; Whether the belt and its coupling buckle are in good condition.
5. The starting equipment of the motor should also be wiped with external dust in time, and you can wipe the contacts, check whether there are burn marks on each wiring part, and whether the grounding wire is good.
6. Inspection and maintenance of bearings. Bearings should be cleaned and replaced with grease or oil after a period of use. The time of cleaning and oil change should be determined by the working condition of the motor, the working environment, the degree of cleanliness, and the type of lubricant. When the oil temperature is high, or the motor with poor environmental conditions and a lot of dust should be cleaned and changed frequently.
7. Inspection of insulation. The insulating capacity of the insulating material varies depending on the degree of drying, so it is important to check the dryness of the motor windings. The working environment of the motor is humid, there are corrosive gases in the working room and other factors, which will destroy the electrical insulation.
The most common is the winding grounding fault, that is, the insulation is damaged, so that the live part collides with the metal part that should not be charged such as the casing, and this fault occurs, which not only affects the normal operation of the motor, but also endangers personal safety. Therefore, in the use of the motor, the insulation resistance should be checked frequently, and attention should be paid to check whether the grounding of the motor casing is reliable.
8. In addition to the regular maintenance of the motor according to the above contents, it should be overhauled once after one year of operation. The purpose of the overhaul is to carry out a thorough and comprehensive inspection and maintenance of the motor, supplement the missing and worn components of the motor, completely eliminate the dust and dirt inside and outside the motor, check the insulation, clean the bearings and check their wear. Find problems and deal with them in a timely manner.
|
More on that
|
Classification and characteristics of the human-machine interface of Buke
MT4000 series
MT4000 series HMI is a sub-series of eView HMI, which is one of Buke's HMI products
Series, human-machine interface MT4000 is referred to as ordinary application series. MT4000 series HMI products adopt 32 ...
|
|
Buke servo motor - what is the difference between servo motor and control motor? How to choose a motor?
What are the main differences between the two?
1. The way of control is different
Stepper motor: The rotation angle is controlled by controlling the number of pulses, and one pulse corresponds to a step angle.
Servo motor: The angle of rotation is controlled by controlling the length of the pulse time.
2. Work ...
|
|
Buke servo motor - how to detect the quality of three-phase AC motor?
1. Shake the meter, 500V can shake the meter, and shake the insulation resistance of the line on the three binding posts to the motor shell, which should be above 0.5M ohm, which means that there is no short circuit to the ground (Yantai motor maintenance).
2. Multimeter measurement: measure the resistance between the three phases of A/B/C, whether it is equal, it should be about the same...
|
|
Buke servo motor - the structural composition of the servo system
1. Comparison link
The comparison link is to compare the input command signal with the feedback signal of the system to obtain the deviation signal between the output and the input, which is usually implemented by a special circuit or computer.
2. a controller
The controller is usually a computer or PI...
|
|
Buke servo motor - what is the cause of servo motor jitter?
Point 1
When the servo motor jitters at zero speed, the gain should be set high, which can reduce the gain value. If the alarm stops when starting, the most likely is that the phase sequence of the motor is incorrect.
Point 2
1. When the PID gain adjustment is too large, it is easy to induce...
|
|
Buke servo motor - what are the daily maintenance tasks of servo motor?
The servo motor can control the speed, the position accuracy is very accurate, and the voltage signal can be converted into torque and speed to drive the control object. The rotor speed of the servo motor is controlled by the input signal, and can respond quickly, in the automatic control system, used as an actuator, and has an electromechanical time constant...
|
|
The basic concept of human-machine interface - Buke
Hmi:
Human-machine interface refers to the field in which man and machine contact or interact with each other in information exchange and function, or the human-machine interface mentioned in the interface.
Information exchange, functional contact or mutual influence, refers to the hard contact and soft contact between man and machine, this combination includes not only dots and lines...
|
|
Buke servo motor - what are the basic applications of AC servo motor?
Material metering
The measurement of powdery materials is commonly used in the way of screw measurement. The purpose of measurement is achieved by the number of turns of the screw rotation. In order to improve the accuracy of measurement, the speed of the screw is required to be adjustable, and the position positioning is accurate.
|
|
Buke servo motor - the cause of common faults in motors
1. Sweeping: Sweeping is generally caused by friction of the stator and rotor due to bearing damage, shaft bending, or improper assembly during maintenance. In the process of overhaul and assembly of the motor, the parts of the motor should be kept clean, and the assembly of the end cover, bearing, etc. should be reasonable and not barbaric construction, otherwise ...
|
|
The causes and solutions of the shutdown of the Buke motor due to pollution
Reasons for the shutdown of the speed up Buke motor due to contamination:
1. Bearing lubrication failure or bearing surface damage
Contaminants can disrupt bearing lubrication and damage bearing surfaces. This will cause the friction to generate heat. If the problem cannot be solved, the increased heat may cause the bearing and the ...
|
|
Common models of Buke inverters
Common models of Buke inverters
Buke CV100 series mini inverter
The output frequency is 0-300Hz
The carrier frequency is up to 15kHz, which effectively reduces the noise of the inverter
It is equipped with RS-485 communication port as standard and supports Modbus communication protocol
Sleep/wake function, inner ...
|
|
Buke servo motor - a common fault of AC servo motor
1. Bearing failure is one of the most common motor failures. As the most important consumable part in servo motors, more than half of the failures of servo motors are usually caused by bearing problems. Its specific manifestations are varied, from jitter and abnormal noise when the motor rotates to the jamming of the motor shaft. Value...
|
|
Buke touch screen recommended model - MT4000 series
1. Product introduction
USING 32-BIT RISC CPU AND A STREAMLINED LINUX KERNEL, THE MT4000 SERIES OF HUMAN-MACHINE INTERFACE PRODUCTS CAN DISPLAY A VARIETY OF TRUE-COLOR GRAPHICS FORMATS, AND ITS OUTSTANDING PROCESSING SPEED AND RICH SOFTWARE FUNCTIONS CAN MEET THE NEEDS OF MOST USERS. Support with the vast majority of PLCs directly ...
|
|
Buke launched the MK series enhanced 4.3-inch all-in-one computer
Buke MK series all-in-one machine on the market for more than a year, received unanimous praise from many customers, in the Buke "quality first" to create an end-to-end full life cycle product quality management system" and "demand management" under the internal and external drive, through the application feedback of this series of products and in order to fit more ...
|
|
Buke servo motor - servo motor maintenance needs to pay attention to
1. Check the servo motor to ensure that there is no fatal damage outside;
2. Check the fixed parts of the servo motor to ensure that the connection is strong;
3. Check the output shaft of the servo motor to ensure the rotation and circulation;
4. Check the encoder connection line of the servo motor and the ...
|
|
What should I do if the Buke servo drive alarm 0006?
Drive Alarm 0006 Please troubleshoot in the following order:
1. Is the motor model correctly configured?
2. Is the motor encoder cable firmly connected?
3. If the above two points are correct, please replace the motor or driver for cross-comparison and troubleshooting.
As mentioned above ...
|
|
Buke Motor - What is the reason for choosing a frameless motor?
· They offer significant cost-effectiveness
· They provide smoother operation
· they are very efficient and tend to reduce energy costs
· can optimize thermal management by embedding the motor into the machine
· They offer improved servo performance and therefore improved production ...
|
|
Buke human-machine interface - the basic functions and selection indicators of human-machine interface products
1) The working status of the equipment is displayed;
2) Data and text input operation, printout;
3) Production formula storage, equipment production data recording;
4) simple logical and numerical operations;
5) It can be connected to a variety of industrial control equipment networking.
...
|
|
Buke servo motor - the output signal of the servo motor encoder
1. OC output: It is commonly said that the triode output, and the input impedance and circuit circuit need to be considered for connection.
2. Voltage output: In fact, it is also a format of OC output, but it has a built-in active circuit.
3. Push-pull output: the interface is easy to connect, no need to consider NPN and PN ...
|
|
Buke servo motor - inspection method before motor starting
1. For new or long-term out-of-service motors, the insulation resistance between the windings and the windings to the ground should be checked before use. Usually for motors below 500V, 500V insulation resistance meter is used; 1000V insulation resistance meter for 500-1000V motors; 2500V insulation resistance meter for motors above 1000V. Insulated ...
|
|