Buke touch screen - daily maintenance and main matters of touch screen
Daily maintenance of the touch screen:
1. The capacitive touch screen should generally be filmed, and it should be pasted well. membranes (double-layer membranes) that meet ESD standards;
2. The capacitive touch screen is cleaned regularly, and the liquid crystal cleaning solution used for the computer is used (alcohol and furniture cleaning liquid cannot be used);
3. Transport...
|
|
Buke human-machine interface - the basic function of human-machine interface products
1) The working status of the equipment is displayed;
2) Data and text input operation, printout;
3) Production formula storage, equipment production data recording;
4) simple logical and numerical operations;
5) It can be connected to a variety of industrial control equipment networking.
...
|
|
Buke servo motor - what are the daily maintenance tasks of servo motor?
The servo motor can control the speed, the position accuracy is very accurate, and the voltage signal can be converted into torque and speed to drive the control object. The rotor speed of the servo motor is controlled by the input signal, and can respond quickly, in the automatic control system, used as an actuator, and has an electromechanical time constant...
|
|
Buke touch screen unresponsive maintenance method
1. Touch screen maintenance, touch no response fault phenomenon:
When touching the screen, the mouse arrows do not move, and the position does not change.
Second, the cause of the failure of touch screen maintenance touch non-response:
(1) On the surface of the acoustic wave touch screen, the sound wave reflection stripes on the four perimeters ...
|
|
Buke servo motor - what are the speed regulation methods of servo motor?
1. If the servo motor is an AC motor, it is a DC inverter air conditioner for speed regulation; If the servo motor is a DC brushless DC motor, it is the DC power supply DC transformer speed regulation; All servo motors can be used as "PLC motor speed regulating power supply circuit servo motor".
2、 ...
|
|
Buke servo - introduction of four common servo control systems
1. Hydraulic servo control system
The hydraulic servo control system is based on the power provided by the motor, and the hydraulic pump is used to convert the mechanical energy into pressure and push the hydraulic oil. By controlling various valves to change the flow direction of the hydraulic oil, so as to push the hydraulic cylinder to make different strokes, different directions of the movement...
|
|
Buke servo motor - common fault causes and maintenance methods of servo motor encoders
1. Start the servo motor before work
(1) Measure the insulation resistance (0.5M or more for low-voltage motors).
(2) Measure the power supply voltage, check whether the wiring of the motor is correct, and whether the power supply voltage meets the requirements.
(3) Check whether the starting device is normal.
( ...
|
|
Buke servo motor - the maintenance method of the motor
1. Clean the motor and remove the dust and sludge outside the motor base in time. If there is a lot of dust in the environment, it is best to clean it once a day.
2. Check and wipe the motor terminals. Check whether the junction box wiring screws are loose or burned.
3. Check the screws of each fixing part, ...
|
|
Buke servo motor - the structural composition of the servo system
1. Comparison link
The comparison link is to compare the input command signal with the feedback signal of the system to obtain the deviation signal between the output and the input, which is usually implemented by a special circuit or computer.
2. a controller
The controller is usually a computer or PI...
|
|
Buke motor - stepper servo drive as soon as it moves, what is the reason for the alarm
First, the common causes of such faults caused by mechanical oscillation (acceleration/deceleration) when the motor is powered on are:
(1) The pulse encoder is faulty. At this time, the servo system should be checked to see if it is stable, whether the circuit board maintenance detection current is stable, and at the same time, the electrical ...
|
|
Buke servo motor - the main feature of the servo system
(1) Accurate detection device: to form a closed-loop control of speed and position.
(2) There are a variety of feedback comparison principles and methods: according to the principle of information feedback realized by the detection device, the feedback comparison method of the servo system is also different. At present, the commonly used pulse comparison, phase ratio ...
|
|
Buke servo motor - the difference between various motors
The ordinary motors, stepper motors, servo motors, and servos mentioned here refer to DC micro motors, and most of the DC motors we usually come into contact with. An electric motor, also known as a "motor", refers to an electromagnetic induction device that maintains the transformation or transmission of electromagnetic energy according to the laws of electromagnetic induction. Motor...
|
|
Buke servo motor - servo motor common faults and solutions
1. How to deal with the servo motor not running when there is pulse output?
a. Monitor the current value of the pulse output of the controller and whether the pulse output light is flashing, and confirm that the command pulse has been executed and the pulse has been output normally;
b. Check the control cable from the controller to the driver, ...
|
|
Buke human-machine interface - what principles should be considered in the design of human-machine interface?
1. The basic design principle of user-centered
In the design process of the system, the designer should grasp the characteristics of the user and discover the user's needs. In the whole development process of the system, it is necessary to continuously solicit the opinions of users and consult with users. The design decision of the system should be combined with the user's work.
|
|
Buke servo motor - the fault phenomenon that the servo motor encoder is broken
1. Communication cannot be connected.
2. The interference in the process of data transmission will increase (sometimes it is not bad, but the connection between the host computer and the servo is incorrect, or there is a falling off, which is a very common problem).
3. The motor will run, but it will not work according to the instructions given by the servo ...
|
|
Buke servo motor - daily maintenance of AC motor
1. In the daily inspection, the lubrication system, appearance, temperature, noise, vibration and abnormal phenomena are mainly checked, and the ventilation and cooling system, sliding friction and fastening of each component are also checked, and the inspection records are carefully made.
2. During the monthly or regular inspection, the main inspection ...
|
|
Buke servo motor - the requirement of the servo feed system
1. Wide range of speed regulation
2. High positioning accuracy
3. There is sufficient transmission rigidity and high speed stability
4. Fast response, no overshoot
In order to ensure productivity and processing quality, in addition to high positioning accuracy, it is also required to have a good and fast response ...
|
|
Common faults and solutions of man-machine interface - Buke
Human-machine interface refers to the field where man and machine contact or interact with each other in information exchange and function, which facilitates our lives, but it is inevitable that there will be some failures when using human-machine interface machines, and how should we deal with these failures.
First, the human-machine interface is normal but the computer is not...
|
|
Buke HMI - What principles should be considered in the design of HMI?
1. The basic design principle of user-centered
In the design process of the system, the designer should grasp the characteristics of the user and discover the user's needs. In the whole development process of the system, it is necessary to continuously solicit the opinions of users and consult with users. The design decision of the system should be combined with the user's work.
|
|
Common fault causes and solutions for Buke servo motor maintenance
1. The motor cannot rotate after being energized, but there is no abnormal noise, no peculiar smell and smoke
(1) The cause of the failure
(1) The power supply is not connected (at least two phases are not connected);
(2) Fuse blowing (at least two-phase blowing);
(3) The overcurrent relay is adjusted too small;
(4) The wiring error of the control equipment ...
|